Porque é que as máquinas de triagem de embalagens e testes de semicondutores necessitam de utilizar refrigeradores?
In the semiconductor packaging testing process, especially in the temperature control process of the sorting machine (test probe station), the use of chillers is mainly based on the following reasons:
Temperature stability and accuracy: The performance testing of semiconductor devices is extremely sensitive to temperature. Subtle temperature fluctuations will affect the accuracy of test results and the performance evaluation of the device. The chiller provides a stable low-temperature environment to ensure minimal temperature fluctuations during the test process, ensuring the repeatability and accuracy of test data.
Thermal management: During the test process, especially high-power devices will generate a large amount of heat energy when running. The chiller can effectively take away this heat energy to prevent heat accumulation, keep the test equipment and DUT at a safe operating temperature, and avoid thermal stress damage to the equipment. Or affect the test accuracy.
Improve efficiency: The rapid cooling of the chiller can shorten the time for the device to cool to the test temperature and improve the test efficiency. Especially when multiple temperature cycle tests or rapid temperature changes are required, the efficiency of the chiller is more critical.
Protect devices: The chiller avoids large temperature fluctuations that may be caused by direct use of ambient temperature control, and protects sensitive semiconductor devices, especially new semiconductor materials or precision devices that are sensitive to temperature.
Environmental adaptability: The semiconductor testing environment requires constant temperature and humidity. The chiller is not affected by temperature changes in the external environment and can ensure a stable indoor testing environment even in extreme weather.
Extend the service life: By reasonably controlling the temperature, the chiller avoids overheating, expansion and contraction of the equipment, protects the equipment, and extends the service life of the test equipment.
In summary, the application of chillers in temperature control of semiconductor sealing, testing and sorting machines is a key technical means to ensure test accuracy, efficiency, protect equipment, improve product quality and environmental adaptability, and extend equipment life.
Semiconductor Cooling Chillers
FLT-100℃~90℃
Refrigerador de canal único arrefecido a ar, concebido principalmente para máquinas de gravação. É utilizado para fornecer um controlo de temperatura independente para as paredes laterais da câmara.
FLTZ -45℃~90℃
O método de aquecimento dentro de 40 ℃ adota um compressor de aquecimento a gás quente totalmente fechado, e a máquina opera continuamente por 24 horas O dispositivo de controle de temperatura de semicondutor Chiller é usado principalmente para p...
carregando...
已经是到最后一篇内容了!
Recomendações relacionadas
-
Why Is Temperature Cycling Testing Performed On Chips?
588Why Is Temperature Cycling Testing Performed On Chips? Temperature cycling testing is a technique employed to evaluate the durability of semiconductor chips. By repeatedly exposing the chip to alternating high and low temperatures, this test ...
Ver pormenores -
Série ZLJ
2210Multiple control requirements can be achieved by merging multiple devices into a larger cabinet Used for small heat exchange area and large heat exchange capacity The product directly outputs and...
Ver pormenores -
Expansion Tanks in Semiconductor Chillers
390Expansion tanks stabilize semiconductor chillers, avoiding costly downtime and protecting sensitive equipment from pressure swings.
Ver pormenores -
FLT-100℃~90℃
2510Refrigerador de canal único arrefecido a ar, concebido principalmente para máquinas de gravação. É utilizado para fornecer um controlo de temperatura independente para as paredes laterais da câmara.
Ver pormenores