FLT -100℃~90℃
semiconductor production process water chiller
- Precisão da temperatura±0.1℃
- Controlo do fluxo12~45/min
- TipoFrequency Variable Series
- Gama de potência380V


FLTZ -100℃~+90℃ Low Temperature Cascade Refrigeration Series
Modelo | FLTZ-002 | FLTZ-003 | FLTZ-004 | FLTZ-006 | FLTZ-008 | FLTZ-010 | FLTZ-015 |
FLTZ-002W | FLTZ-003W | FLTZ-004W | FLTZ-006W | FLTZ-008W | FLTZ-010W | FLTZ-015W | |
Gama de temperaturas | 5℃~90℃ | ||||||
Precisão do controlo da temperatura | ±0.05℃(Steady state outlet temperature) | ||||||
Cooling capacity @10℃ | 6kW | 8kW | 10kW | 15kW | 20kW | 25kW | 40kW |
Volume do fluido de circulação interna | 4L | 5L | 6L | 8L | 10L | 12L | 20L |
Volume do depósito de expansão | 10L | 10L | 15L | 15L | 20L | 25L | 35L |
Refrigerante | R410A | ||||||
Refrigerating medium | Silicone oil, fluorinated liquid, polyol aqueous solution, DI, etc. (DI temp needs to be controlled above 10 ℃) | ||||||
Tamanho da ligação | ZG1/2 | ZG1/2 | ZG3/4 | ZG3/4 | ZG3/4 | ZG1 | ZG1 |
Cooling water connection size | ZG1/2 | ZG1/2 | ZG3/4 | ZG1 | ZG1 | ZG1 | ZG1 1/8 |
Fluxo de água de arrefecimento @20℃ | 1,5m³/h | 2m³/h | 2,5m³/h | 4m³/h | 4,5m³/h | 5,6m³/h | 9m³/h |
Process temperature control | The remote target temperature can be controlled by combining the self created model free self built tree algorithm and cascade algorithm |
||||||
Dimensão cm | 950*380*1055 | 950*380*1055 | 950*380*1055 | 980*430*1400 | 980*430*1400 | 1080*600*1500 | 1080*600*1500 |
Modelo | FLTZ-1002W | FLTZ-1004W |
Gama de temperaturas | -100℃~+90℃ | |
Precisão do controlo da temperatura | ±0.05℃(Steady state outlet temperature) | |
Controlo do fluxo | 7~25L/min | 12~45L/min |
Cooling capacityat-90℃ | 1.5kW | 3kW |
Capacidade de aquecimento | 3,5 kW | 5,5 kW |
Volume do fluido de circulação interna | 5L | 8L |
Volume do depósito de expansão | 10L | 15L |
Heat-conduction medium | Líquido fluorado | |
Tamanho da ligação | ZG3/4 | ZG3/4 |
Cooling water connection size | ZG3/4 | ZG1 |
Cooling water@20℃ | 50L/min 2bar~7bar | 100L/min 2bar~7bar |
Circuit breaker | 32A | 63A |
Process temperature control | The remote target temperature can be controlled by combining the self created model free self built tree algorithm and cascade algorithm |
FLTZ -45℃~90℃
Modelo | FLTZ-002 | FLTZ-003 | FLTZ-004 | FLTZ-006 | FLTZ-008 | FLTZ-010 | FLTZ-015 |
FLTZ-002W | FLTZ-003W | FLTZ-004W | FLTZ-006W | FLTZ-008W | FLTZ-010W | FLTZ-015W | |
Gama de temperaturas | 5℃~90℃ | ||||||
Precisão do controlo da temperatura | ±0.05℃(Steady state outlet temperature) | ||||||
Cooling capacity @10℃ | 6kW | 8kW | 10kW | 15kW | 20kW | 25kW | 40kW |
Volume do fluido de circulação interna | 4L | 5L | 6L | 8L | 10L | 12L | 20L |
Volume do depósito de expansão | 10L | 10L | 15L | 15L | 20L | 25L | 35L |
Refrigerante | R410A | ||||||
Refrigerating medium | Silicone oil, fluorinated liquid, polyol aqueous solution, DI, etc. (DI temp needs to be controlled above 10 ℃) | ||||||
Tamanho da ligação | ZG1/2 | ZG1/2 | ZG3/4 | ZG3/4 | ZG3/4 | ZG1 | ZG1 |
Cooling water connection size | ZG1/2 | ZG1/2 | ZG3/4 | ZG1 | ZG1 | ZG1 | ZG1 1/8 |
Fluxo de água de arrefecimento @20℃ | 1,5m³/h | 2m³/h | 2,5m³/h | 4m³/h | 4,5m³/h | 5,6m³/h | 9m³/h |
Process temperature control | The remote target temperature can be controlled by combining the self created model free self built tree algorithm and cascade algorithm |
||||||
Dimensão cm | 950*380*1055 | 950*380*1055 | 950*380*1055 | 980*430*1400 | 980*430*1400 | 1080*600*1500 | 1080*600*1500 |
Modelo | FLTZ-202 | FLTZ-203 | FLTZ-204 | FLTZ-206 | FLTZ-208 | FLTZ-210 | FLTZ-215 |
FLTZ-202W | FLTZ-203W | FLTZ-204W | FLTZ-206W | FLTZ-208W | FLTZ-210W | FLTZ-215W | |
Gama de temperaturas | -25℃~90℃ | ||||||
Precisão do controlo da temperatura | ±0.05℃(Steady state outlet temperature) | ||||||
Controlo do fluxo | 10~25L/min | 15~45L/min | 25~75L/min | ||||
Cooling capacity @-15℃ | 2kW | 3kW | 3,8kW | 6kW | 7.6kW | 10kW | 15kW |
Volume do fluido de circulação interna | 4L | 5L | 6L | 8L | 10L | 12L | 20L |
Volume do depósito de expansão | 10L | 10L | 15L | 15L | 20L | 25L | 35L |
Refrigerante | R404A | ||||||
Refrigerating medium | Silicone oil, fluorinated liquid, glycol solution etc | ||||||
Tamanho da ligação | ZG1/2 | ZG1/2 | ZG3/4 | ZG3/4 | ZG3/4 | ZG1 | ZG1 |
Cooling water connection size | ZG1/2 | ZG1/2 | ZG3/4 | ZG3/4 | ZG1 | ZG1 | ZG1 1/8 |
Fluxo de água de arrefecimento @20℃ | 1,2 m³/H | 1,6 m³/H | 2,6 m³/H | 3,6 m³/H | 5,5 m³/H | 7m³/H | 10,2 m³/H |
Process temperature control | The remote target temperature can be controlled by combining the self created model free self built tree algorithm and cascade algorithm |
||||||
Dimensão cm | 950*380*1055 | 950*380*1055 | 950*380*1055 | 980*430*1400 | 980*430*1400 | 1080*600*1500 | 1080*600*1500 |
Modelo | FLTZ-402 | FLTZ-403 | FLTZ-404 | FLTZ-406 | FLTZ-408 | FLTZ-410 | FLTZ-415 |
FLTZ-402W | FLTZ-403W | FLTZ-404W | FLTZ-406W | FLTZ-408W | FLTZ-410W | FLTZ-415W | |
Gama de temperaturas | -45℃~90℃ | ||||||
Precisão do controlo da temperatura | ±0.05℃(Steady state outlet temperature) | ||||||
Controlo do fluxo | 10~25L/min 5bar max | 15~45L/min 5bar max | 25~75L/min 5bar max | ||||
Aquecimento | Using compressor heating, prevent condenser frosting technology | ||||||
Cooling capacity @-35℃ | 1kW | 1.4kW | 1,8kW | 2.5kW | 3,3kW | 5kW | 8kW |
Volume do fluido de circulação interna | 4L | 5L | 6L | 8L | 10L | 12L | 20L |
Volume do depósito de expansão | 10L | 10L | 15L | 15L | 20L | 25L | 35L |
Refrigerante | R404A | ||||||
Refrigerating medium | Silicone oil, fluorinated liquid, glycol solution etc | ||||||
Tamanho da ligação | ZG1/2 | ZG1/2 | ZG3/4 | ZG3/4 | ZG3/4 | ZG1 | ZG1 |
Cooling water connection size | ZG1/2 | ZG3/4 | ZG3/4 | ZG1 | ZG1 | ZG1 | ZG1 1/8 |
Fluxo de água de arrefecimento @20℃ | 1,5 m³/H | 2,4 m³/H | 3,5 m³/H | 5m³/H | 5,5 m³/H | 6m³/H | 8m³/H |
Process temperature control | The remote target temperature can be controlled by combining the self created model free self built tree algorithm and cascade algorithm |
||||||
Dimensão cm | 950*380*1055 | 950*380*1055 | 950*380*1055 | 980*430*1400 | 980*430*1400 | 1080*500*1500 | 1080*500*1500 |
Heat exchange Chiller Compressor-free
Modelo | ETCU-005W | ETCU-015W | ETCU-030W | ETCU-050W | ETCU-100W | ETCU-200W | ETCU-300W |
Gama de temperaturas | Cooling water temperature +5℃~90℃ | ||||||
Precisão do controlo da temperatura | ±0.05℃(Steady state outlet temperature) | ||||||
Temperatura da água de arrefecimento | 7℃~30℃ Cooling water flow is controlled by Siemens/Honeywell regulating valves | ||||||
Capacidade de arrefecimento | 5kW | 15kW | 30kW | 50kW | 100kW | 200kW | 300kW |
Test conditions: When the maximum circulation amount, the temperature difference between the temperature control temperature and the cooling water temperature is 15℃ |
|||||||
Bomba de circulação | 7~20L/min 5bar | 15~40L/min 5bar | 20~60L/min 5bar | 40~110L/min 5bar | 150~250L/min 5bar | 250~500L/min 5bar | 400~650L/min 5bar |
Volume do depósito | 5L | 10L | 20L | 30L | 60L | 120L | 240L |
Dimensão cm | 480*750*390 | 480*750*390 | 480*750*500 | Customization | Customization | Customization | Customization |



refrigeradores que controlam a temperatura de processamento nos equipamentos Fab

Refrigerador de canal único arrefecido a ar, concebido principalmente para máquinas de gravação. É utilizado para fornecer um controlo de temperatura independente para as paredes laterais da câmara.
Aplicações

Envie-nos o seu pedido e entraremos em contacto consigo no prazo de 24 horas
recomendar produtos
FLTZ -45℃~90℃
O método de aquecimento dentro de 40 ℃ adota um compressor de aquecimento a gás quente totalmente fechado, e a máquina opera continuamente por 24 horas O dispositivo de controle de temperatura de semicondutor Chiller é usado principalmente para p...
carregando...
已经是到最后一篇内容了!