Pesquisar toda a estação


Centro de notícias

FLT-100℃~90℃ low temperature cascade
  • Precisão da temperatura±0.1℃
  • Controlo do fluxo12~45/min
  • TipoFrequency Variable Series
  • Gama de potência380V

FLTZ -100℃~+90℃ Low Temperature Cascade Refrigeration Series

Modelo FLTZ-002 FLTZ-003 FLTZ-004 FLTZ-006 FLTZ-008 FLTZ-010 FLTZ-015
FLTZ-002W FLTZ-003W FLTZ-004W FLTZ-006W FLTZ-008W FLTZ-010W FLTZ-015W
Gama de temperaturas 5℃~90℃
Precisão do controlo da temperatura ±0.05℃(Steady state outlet temperature)
Cooling capacity @10℃ 6kW 8kW 10kW 15kW 20kW 25kW 40kW
Volume do fluido de circulação interna 4L 5L 6L 8L 10L 12L 20L
Volume do depósito de expansão 10L 10L 15L 15L 20L 25L 35L
Refrigerante R410A
Refrigerating medium Silicone oil, fluorinated liquid, polyol aqueous solution, DI, etc. (DI temp needs to be controlled above 10 ℃)
Tamanho da ligação ZG1/2 ZG1/2 ZG3/4 ZG3/4 ZG3/4 ZG1 ZG1
Cooling water connection size ZG1/2 ZG1/2 ZG3/4 ZG1 ZG1 ZG1 ZG1 1/8
Fluxo de água de arrefecimento @20℃ 1,5m³/h 2m³/h 2,5m³/h 4m³/h 4,5m³/h 5,6m³/h 9m³/h
Process temperature control The remote target temperature can be controlled by combining the self created model free self
 built tree algorithm and cascade algorithm
Dimensão cm 950*380*1055 950*380*1055 950*380*1055 980*430*1400 980*430*1400 1080*600*1500 1080*600*1500

Modelo FLTZ-1002W FLTZ-1004W
Gama de temperaturas  -100℃~+90℃
Precisão do controlo da temperatura ±0.05℃(Steady state outlet temperature)
Controlo do fluxo 7~25L/min 12~45L/min
Cooling capacityat-90℃ 1.5kW 3kW
Capacidade de aquecimento 3,5 kW 5,5 kW
Volume do fluido de circulação interna 5L 8L
Volume do depósito de expansão 10L 15L
Heat-conduction medium Líquido fluorado
Tamanho da ligação ZG3/4 ZG3/4
Cooling water connection size ZG3/4 ZG1
Cooling water@20℃ 50L/min 2bar~7bar 100L/min 2bar~7bar
Circuit breaker 32A 63A
Process temperature control The remote target temperature can be controlled by combining the self created model free self
 built tree algorithm and cascade algorithm
FLTZ -45℃~90℃

Modelo FLTZ-002 FLTZ-003 FLTZ-004 FLTZ-006 FLTZ-008 FLTZ-010 FLTZ-015
FLTZ-002W FLTZ-003W FLTZ-004W FLTZ-006W FLTZ-008W FLTZ-010W FLTZ-015W
Gama de temperaturas 5℃~90℃
Precisão do controlo da temperatura ±0.05℃(Steady state outlet temperature)
Cooling capacity @10℃ 6kW 8kW 10kW 15kW 20kW 25kW 40kW
Volume do fluido de circulação interna 4L 5L 6L 8L 10L 12L 20L
Volume do depósito de expansão 10L 10L 15L 15L 20L 25L 35L
Refrigerante R410A
Refrigerating medium Silicone oil, fluorinated liquid, polyol aqueous solution, DI, etc. (DI temp needs to be controlled above 10 ℃)
Tamanho da ligação ZG1/2 ZG1/2 ZG3/4 ZG3/4 ZG3/4 ZG1 ZG1
Cooling water connection size ZG1/2 ZG1/2 ZG3/4 ZG1 ZG1 ZG1 ZG1 1/8
Fluxo de água de arrefecimento @20℃ 1,5m³/h 2m³/h 2,5m³/h 4m³/h 4,5m³/h 5,6m³/h 9m³/h
Process temperature control The remote target temperature can be controlled by combining the self created model free self
 built tree algorithm and cascade algorithm
Dimensão cm 950*380*1055 950*380*1055 950*380*1055 980*430*1400 980*430*1400 1080*600*1500 1080*600*1500

Modelo FLTZ-202 FLTZ-203 FLTZ-204 FLTZ-206 FLTZ-208 FLTZ-210 FLTZ-215
FLTZ-202W FLTZ-203W FLTZ-204W FLTZ-206W FLTZ-208W FLTZ-210W FLTZ-215W
Gama de temperaturas  -25℃~90℃
Precisão do controlo da temperatura ±0.05℃(Steady state outlet temperature)
Controlo do fluxo 10~25L/min 15~45L/min 25~75L/min
Cooling capacity @-15℃ 2kW 3kW 3,8kW 6kW 7.6kW 10kW 15kW
Volume do fluido de circulação interna 4L 5L 6L 8L 10L 12L 20L
Volume do depósito de expansão 10L 10L 15L 15L 20L 25L 35L
Refrigerante R404A
Refrigerating medium Silicone oil, fluorinated liquid, glycol solution etc
Tamanho da ligação ZG1/2 ZG1/2 ZG3/4 ZG3/4 ZG3/4 ZG1 ZG1
Cooling water connection size ZG1/2 ZG1/2 ZG3/4 ZG3/4 ZG1 ZG1 ZG1 1/8
Fluxo de água de arrefecimento @20℃ 1,2 m³/H 1,6 m³/H 2,6 m³/H 3,6 m³/H 5,5 m³/H 7m³/H 10,2 m³/H
Process temperature control The remote target temperature can be controlled by combining the self created model free self
 built tree algorithm and cascade algorithm
Dimensão cm 950*380*1055 950*380*1055 950*380*1055 980*430*1400 980*430*1400 1080*600*1500 1080*600*1500
Modelo FLTZ-402 FLTZ-403 FLTZ-404 FLTZ-406 FLTZ-408 FLTZ-410 FLTZ-415
FLTZ-402W FLTZ-403W FLTZ-404W FLTZ-406W FLTZ-408W FLTZ-410W FLTZ-415W
Gama de temperaturas  -45℃~90℃
Precisão do controlo da temperatura ±0.05℃(Steady state outlet temperature)
Controlo do fluxo 10~25L/min  5bar max 15~45L/min 5bar max 25~75L/min 5bar max
Aquecimento Using compressor heating, prevent condenser frosting technology
Cooling capacity @-35℃ 1kW 1.4kW 1,8kW 2.5kW 3,3kW 5kW 8kW
Volume do fluido de circulação interna 4L 5L 6L 8L 10L 12L 20L
Volume do depósito de expansão 10L 10L 15L 15L 20L 25L 35L
Refrigerante R404A
Refrigerating medium Silicone oil, fluorinated liquid, glycol solution etc
Tamanho da ligação ZG1/2 ZG1/2 ZG3/4 ZG3/4 ZG3/4 ZG1 ZG1
Cooling water connection size ZG1/2 ZG3/4 ZG3/4 ZG1 ZG1 ZG1 ZG1 1/8
Fluxo de água de arrefecimento @20℃ 1,5 m³/H 2,4 m³/H 3,5 m³/H 5m³/H 5,5 m³/H 6m³/H 8m³/H
Process temperature control The remote target temperature can be controlled by combining the self created model free self
 built tree algorithm and cascade algorithm
Dimensão cm 950*380*1055 950*380*1055 950*380*1055 980*430*1400 980*430*1400 1080*500*1500 1080*500*1500
Heat exchange Chiller Compressor-free

Modelo ETCU-005W ETCU-015W ETCU-030W ETCU-050W ETCU-100W ETCU-200W ETCU-300W
Gama de temperaturas Cooling water temperature +5℃~90℃
Precisão do controlo da temperatura ±0.05℃(Steady state outlet temperature)
Temperatura da água de arrefecimento 7℃~30℃ Cooling water flow is controlled by Siemens/Honeywell regulating valves
Capacidade de arrefecimento 5kW 15kW 30kW 50kW 100kW 200kW 300kW
Test conditions: When the maximum circulation amount, the temperature difference between
the temperature control temperature and the cooling water temperature is 15℃
Bomba de circulação 7~20L/min 5bar 15~40L/min 5bar 20~60L/min 5bar 40~110L/min 5bar 150~250L/min 5bar 250~500L/min 5bar 400~650L/min 5bar
Volume do depósito 5L 10L 20L 30L 60L 120L 240L
Dimensão cm 480*750*390 480*750*390 480*750*500 Customization Customization Customization Customization

Aplicações

Envie-nos o seu pedido e entraremos em contacto consigo no prazo de 24 horas
*
*

Multicanal

Canal 1Canal 2Canal 3

Tensão

50HZ monofásico50HZ trifásico60HZ monofásico60HZ trifásico*
Submeter....
Enviado com sucesso!
A submissão falhou! Tente novamente mais tarde
Erro de correio eletrónico!
Erro telefónico!

recomendar produtos

  • FLTZ -45℃~90℃"      /&gt;<figcaption><span>O método de aquecimento dentro de 40 ℃ adota um compressor de aquecimento a gás quente totalmente fechado, e a máquina opera continuamente por 24 horas O dispositivo de controle de temperatura de semicondutor Chiller é usado principalmente para p...</span></figcaption></figure></a></div><div class=FLTZ -45℃~90℃

    O método de aquecimento dentro de 40 ℃ adota um compressor de aquecimento a gás quente totalmente fechado, e a máquina opera continuamente por 24 horas O dispositivo de controle de temperatura de semicondutor Chiller é usado principalmente para p...

carregando...