Precauções para utilizar o sistema de controlo da temperatura de ensaio de bolachas
The wafer testing temperature control system can provide high and low temperature environments for experimental use. However, as an instrument, its operation also needs to follow certain precautions. This article will introduce in detail the operating precautions of the wafer testing temperature control system to ensure the accuracy and safety of the experiment.
The wafer testing temperature control system mainly consists of a refrigeration system, a heating system, a control system and a temperature sensor. It can achieve accurate control of high and low temperature environments by adjusting the parameters of the heating system and refrigeration system.
FLT-100℃~90℃
Refrigerador de canal único arrefecido a ar, concebido principalmente para máquinas de gravação. É utilizado para fornecer um controlo de temperatura independente para as paredes laterais da câmara.
FLTZ -45℃~90℃
O método de aquecimento dentro de 40 ℃ adota um compressor de aquecimento a gás quente totalmente fechado, e a máquina opera continuamente por 24 horas O dispositivo de controle de temperatura de semicondutor Chiller é usado principalmente para p...
carregando...
已经是到最后一篇内容了!
Before using the wafer to test the temperature control system, we need to conduct a series of checks. Check whether the power connection of the device is normal and whether the power plug is tight. Secondly, check whether the pipeline connections of the equipment are tight and whether there are leaks. In addition, the internal cleanliness of the equipment should be checked to ensure the accuracy of the experimental results.
When operating the wafer testing temperature control system, we need to pay attention to the following tips. Avoid moving or tilting the equipment while it is in operation to avoid unnecessary injury. Secondly, make sure that the experimental samples are placed securely and do not place them on the edge or sliding parts of the equipment to avoid falling and damaging the equipment or causing personal injury.
When setting the temperature, adjust the temperature step by step and always pay attention to the difference between the device’s display temperature and the set temperature. If the difference is too large, the parameters of the heating system and refrigeration system should be adjusted in time. At the same time, it is necessary to keep the equipment clean and clean the condenser, evaporator and other components regularly to ensure the heat dissipation and cooling effect of the equipment.
Long-term use of the wafer test temperature control system may result in equipment performance degradation or failure. Therefore, we must regularly inspect and maintain the equipment to detect and solve problems in a timely manner. At the same time, the filter, oil and other accessories of the equipment should be replaced regularly according to the equipment instructions to ensure the normal operation of the equipment.
In short, the operation of the wafer testing temperature control system requires attention to many aspects. During use, we must strictly abide by the operating procedures of the equipment and always pay attention to the operating status of the equipment and changes in experimental results. At the same time, you also need to pay attention to tips and equipment maintenance precautions to ensure the accuracy and safety of the experiment.
Oferecer 7 * 24 consultas gratuitas e soluções abrangentes


Correio eletrónico: sales@cnzlj.com
WhatsApp: 086 13912479193
Recomendações relacionadas
-
How to purchase a power management chip temperature test system?
585The power management chip temperature test system is an important equipment used to test the performance and reliability of semiconductor chips in different temperature environments. When purchasing this type of test equipment, you need to...
Ver pormenores -
TES -85℃~200℃
1247Temperature control range:-85°C ~ 200°C ;Power range:6.5kW~50kW;Temperature control accuracy:±0.3°C Chip-Specific High and Low Temperature Test Boxes In the manufacture of semiconductor electronic components for harsh env...
Ver pormenores -
Série AI
1159* 1. Widely used in high and low temperature testing of semiconductor equipment.Cold and heat source of electronic equipment at high temperature and low temperature; 2. Independent refrigeration circulating air ...
Ver pormenores -
Vacuum chamber cooling chiller
406Vacuum chamber cooling chiller is a device specially designed to cool the environment in a vacuum chamber to ensure that the temperature in the vacuum chamber is kept within the required working range to meet the needs of specific applicatio...
Ver pormenores