FLTZ Variable Frequency  Series Multi-channel Chillers

FLTZ Variable Frequency Series Multi-channel Chillers

APLICAÇÕES

Semiconductor air cooling & water cooling Chiller is mainly used for precise temperature control in semiconductor production and testing. Products include fluid fluorinated liquid temperature control (minimum -100 degrees), gas hot and cold rapid temperature change, rapid temperature change chuck, low temperature gas refrigerator (-120 degrees), direct cooling refrigeration unit (-150 degrees), etc. The company applies a variety of algorithms (PID, feedforward PID, model-free self-building algorithm) in the system to achieve fast system response and high control accuracy.

FLTZ  -20℃~+90℃ 

 

Modelo FLTZ-203W-2T
Pipeline channel 1 channel 2
Gama de temperaturas  -20℃~+90℃ -20℃~+90℃
Capacidade de arrefecimento 4kW@-10℃ 4kW@-10℃
Capacidade de aquecimento 2kW 2kW
Heat conducting medium flow rate 20L/min@0.5MPa 20L/min@0.5MPa
Heat conducting medium connection size ZG3/4 ZG3/4
Ambient temperature 10~35℃ 10~35℃
Ambient humidity 30~70% 30~70%
Cooling water flow rate 15~20℃ 15~20℃
Temperatura da água de arrefecimento 20L/min 20L/min
Circuit breaker 30A
Peso 400 kg
Dimensão cm 500*900*1600

 

FLTZ   -45℃~+40

 

Modelo FLTZ-406W/ETCU-015W
Pipeline channel 1 channel 2
Gama de temperaturas -45℃~+40 +10℃~+80
Capacidade de arrefecimento 11kW@-20
5kW@-40
13kW@+10
Capacidade de aquecimento 2kW 6kW
Heat conducting medium flow rate 17L/min@0.7MPa 17L/min@0.7MPa
Heat conducting medium connection size ZG3/4 ZG3/4
Ambient temperature 1035 1035
Ambient humidity 3070% 3070%
Cooling water flow rate 1520 1520
Temperatura da água de arrefecimento 40L/min 20L/min
Circuit breaker 80A
Peso 550kg
Dimensão cm 600*1000*1850

 

FLTZ  -10℃~+80℃

 

Modelo FLTZ-203W/ETCU-008W
Pipeline channel 1 channel 2 channel 3
Gama de temperaturas -10℃~+60℃ +30℃~+80℃ -10℃~+80℃
Capacidade de arrefecimento 4kW@-10℃/21kW@+20℃ 6 kW@+30℃ 3kW@-10℃
Capacidade de aquecimento 4kW 4.5+6kW 3kW
Heat conducting medium flow rate 17L/min@0.7MPa 17L/min@0.7MPa 17L/min@0.7MPa
Heat conducting medium connection size ZG3/4 ZG3/4 ZG3/4
Ambient temperature 10~35 ℃ 10~35 ℃ 10~35 ℃
Ambient humidity 30~70% 30~70% 30~70%
Cooling water flow rate 15~20℃ 15~20℃ 15~20℃
Temperatura da água de arrefecimento 30L/min@15~20℃ 15L/min@15~20℃ 15L/min@15~20℃
Circuit breaker 100A
Peso 600kg
Dimensão cm 600*1000*1700

 

FLTZ  -20℃~+50℃

 

Modelo FLT-215W/ETCU-015W/ETCU-008W
Pipeline channel 1 channel 2 channel 3
Gama de temperaturas -20℃~+50℃ +30℃~+100℃ +30℃~+40℃
Capacidade de arrefecimento 15kW@-10℃ 13kW@PCW+15℃ 8kW@PCW+10℃
Capacidade de aquecimento 2kW 6kW Pump Heat Loss
Heat conducting medium flow rate 30L/min@0.85MPa 30L/min@0.85MPa 20L/min@0.8MPa
Heat conducting medium connection size ZG3/4 ZG3/4 ZG3/4
Ambient temperature 10~35 ℃ 10~35 ℃ 10~35 ℃
Ambient humidity 30~70% 30~70% 30~70%
Cooling water flow rate 15~20℃ 15~20℃ 15~20℃
Temperatura da água de arrefecimento 30L/min@15~20℃ 15L/min@15~20℃ 15L/min@15~20℃
Circuit breaker 75A
Peso 600kg
Dimensão cm 600*1000*1700

 

FLTZ  -45℃~90℃

 

Modelo FLTZ-203W/2T dual system FLTZ-305W/2T  dual system FLTZ-406W/2T dual system
Gama de temperaturas -20℃~90℃  -30℃~90℃ -45℃~90℃
Heat conducting medium flow rate 15~45l/min 6bar max
Capacidade de aquecimento 2.5kW 2.5kW 2.5kW 2.5kW 3,5 kW 3,5 kW
Capacidade de arrefecimento 3kW at-15℃ 3kW at-15℃ 5kW at-15℃ 5kW at-15℃ 2.5kW at -35℃ 2.5kW at -35℃
Volume do fluido da circulação interna 5L 5L 8L 8L 8L 8L
Volume do depósito de expansão 15L 25L 25L
Heat-conducting medium Fluorinated liquid, antifreeze, thermal conductive silicone oil, etc
Refrigerante R404A/ R448
Heat-conducting medium interface ZG3/4
Interface da água de arrefecimento ZG3/4
Interface da água de arrefecimento 50L/min at20℃ 600L/min at20℃ 50L/min at20℃
Potência Three phase 220V/Three phase 400V/Three phase 460V

 

A bomba de frequência variável pode ajustar a pressão hidráulica de circulação e o caudal

Communication function

APLICAÇÕES

Unidade de controlo da temperatura do processo FAB de semicondutores

O fabrico de semicondutores é um processo com requisitos ambientais extremamente elevados, e muitas etapas do processo são muito sensíveis à temperatura.
O controlo preciso da temperatura pode garantir uma espessura uniforme e uma composição exacta das películas depositadas, melhorando assim o desempenho e o rendimento das pastilhas.

for Semiconductor packaging & testing process

O processo de embalagem e ensaio de semicondutores é um elo fundamental no processo de produção de semicondutores, incluindo o ensaio de bolachas, a embalagem de pastilhas e o ensaio pós-embalagem. Este processo exige não só um elevado grau de precisão e fiabilidade, mas também um controlo rigoroso da temperatura para garantir a qualidade e o desempenho do produto.

Such as chillers that control the processing temperature on the Fab equipments.

Cooling of CMOS/CCD sensors in semiconductor metrology systems.

Recirculating Chiller for semiconductor metering AOI system.

Refrigerador de canal único arrefecido a ar, concebido principalmente para máquinas de gravação. É utilizado para fornecer um controlo de temperatura independente para as paredes laterais da câmara.

Used for plasma bevel etch and deposition; Thermal Atomic Layer Etching of Metal Tungsten.


Since our founding in 2006, we have served over 30,000 customers and hold several patents that demonstrate our innovation and reliability. Our chillers are selected for over 100 university laboratory projects worldwide and exported to over 20 countries. We ensure the highest quality through a rigorous 3-step quality control process: visual inspection, performance testing, and electrical safety testing. Our commitment to excellence is further backed by our 24/7 customer support commitment. In addition, we have agents in the United States, Canada, Australia, Russia, and South Korea, making us a global, trusted partner for your chiller needs. Choose lneya for quality and support for your project.
18+

Years of experience

30000+

Satisfied Customers

25000

m² Production Area

80+

Patented Technologies

*
*
Submeter....
Enviado com sucesso!
A submissão falhou! Tente novamente mais tarde
Erro de correio eletrónico!
Erro telefónico!