LQ -40°C~-110°C
Semiconductor test chiller For non corrosive gas cooling- Potência de aquecimento2.5kW~25kW
- Capacidade de arrefecimento0,25kW~25kW
- Gama de potência6,5kW~50kW
- Precisão média±0.3℃
- Pressão de fluxo20L/min~150L/min 2,5bar
- RefrigeranteR404A/R508B
Descrição do produto
It is used to cool the gas (non corrosive) or recover it as non corrosive gas by condensation and liquefaction.
Pressure resistance of gas heat exchange system: 25bar; The temperature range is – 40 ℃ ~ – 75 ℃, which can meet different temperatures;
The secondary subcooling technology is adopted, with rapid refrigeration and low refrigeration temperature;
Semi closed piston compressor, scroll flexible compressor and fully closed piston compressor of imported brands are adopted;
The evaporator adopts casing heat exchanger, which has the advantages of small volume, long residence time and high efficiency;
Danfoss expansion valve and Emerson electronic expansion valve are adopted, with high temperature control accuracy;
Siemens plcs7-200 / 300 and lneya touch screen display are used for automatic control operation;
The whole machine is installed. The system has been tested in the factory. Users only need to install the refrigerant pipeline and cooling water pipeline to run;
Factory test: each refrigeration unit shall be tested with load in the factory for no less than 12 hours;
Modelo | LQ-4015 | LQ-4030 | LQ-4060 | LQ-40100 | LQ-7515 | LQ-7530 | LQ-7560 | LQ-75100 |
LQ-4015W | LQ-4030W | LQ-4060W | LQ-40100W | LQ-7515W | LQ-7530W | LQ-7560W | LQ-75100W | |
Caudal de gás | 15m3/h | 30m3/h | 60m3/h | 100m3/h | 15m3/h | 30m3/h | 60m3/h | 100m3/h |
lowest temp. | -40℃ | -40℃ | -40℃ | -40℃ | -75℃ | -75℃ | -75℃ | -75℃ |
Área de permuta de calor | 0.8m2 | 1.5m2 | 3m2 | 5m2 | 1.5m2 | 2.5m2 | 5m2 | 9m2 |
Material do permutador de calor | Standard configuration sus304 contains a small amount of copper | |||||||
Gas inlet and outlet diameter | G3/8 | G1/2 | G1 | DN50 | G3/8 | G1/2 | G1 | DN50 |
Sistema de controlo | Programmable controller and module | |||||||
Visualização e registo | 7-inch color touch screen, record curve temperature and alarm conditions | |||||||
compressor | France Taikang/Emerson Copeland | |||||||
Alimentação eléctrica | 220V 50HZ | 220V 50HZ | 380V 50HZ | 380V 50HZ | 220V 50HZ | 220V 50HZ | 380V 50HZ | 380V 50HZ |
1.2KW | 1.8KW | 3,5KW | 7KW | 2KW | 3KW | 6KW | 11.5KW |

Também pode estar interessado nestes produtos
Mandril da série MD
-75℃ a 225°C Modelo MD-708 MD-712 MDL-708 Temp. Faixa -75℃~225℃ -75℃~225℃ -75℃~225℃ Precisão do controle de temperatura ±0.1℃ ±0.1℃ ±0.1℃ uniformidade de temperatura ±1℃ ±1℃ ±1℃ Planicidade ±50um ±50um ±50um ±50um Tamanho do comprimido 200mm de diâmetro d...
YQH 0℃~-75℃
Adequado para a recuperação de vários gases VOCs voláteis; Arrefecimento rápido, alta eficiência, atendendo a diferentes requisitos de temperatura de condensação, a baixa temperatura pode chegar a -75 ° C. Ele vem principalmente da limpeza, cola ...
FLT-100℃~90℃
Refrigerador de canal único arrefecido a ar, concebido principalmente para máquinas de gravação. É utilizado para fornecer um controlo de temperatura independente para as paredes laterais da câmara.
FLTZ -45℃~90℃
O método de aquecimento dentro de 40 ℃ adota um compressor de aquecimento a gás quente totalmente fechado, e a máquina opera continuamente por 24 horas O dispositivo de controle de temperatura de semicondutor Chiller é usado principalmente para p...