Temperature Forcing System/ Thermal Stream Head
AES -115℃~225℃
- Time switching10s~20s
- RefrigeranteR404A/R23/R14/R508B
- Água de arrefecimento0.6m³/h~3m³/h
- Gama de potência3,7kW~7,5kW

TEMP SHOCK TEST AIRFLOW HOOD
Thermal Solutions for ATE testing
1/CHARACTERISTIC ANALYSIS
2/LOOP TEST
3/IMPACT TEST
4/FAILURE ANALYSIS
Suitable for IC testing of all kinds of semiconductor chips,flash memory Flash/EMMC, PCB circuit boards, opticalcommunications,electronic industries, etc.
AES series for Automatic test equipment in semiconductor, aerospace, military and other industries. Such as ATE is used to measure the output signal of semiconductor devices,Used to evaluate the properties and performance of DUT, UUT, EUT to ensure use.
Parâmetros
Modelo | AES-4535 | AES-6035 | AES-8035 | AES-A1035W | AES-A1235W | |
AES-4535W | AES-6035W | AES-8035W | ||||
Temp. Gama | -45℃~225℃ | -60℃~225℃ | -80℃~225℃ | -100℃~225℃ | -120℃~225℃ | |
Potência de aquecimento | 3,5 kW | 3,5 kW | 3,5 kW | 4,5 kW | 4,5 kW | |
Temp. Control Accuracy | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | |
Temp. Conversion Time | -25℃ to 150℃ Approximately 10S 150℃ to -25℃ Approximately 20s |
-45℃ to 150℃ Approximately 10S 150℃to -45℃ Approximately 20s |
-55℃ to 150℃ Approximately 10S 150℃to -55℃ Approximately 15s |
-70℃ to 150℃ Approximately 10S 150 ℃to -70℃ Approximately 20s |
-80℃ to 150℃ Approximately 11S 150℃to -80℃ Approximately 20s |
|
Air Requirement | Air Cleaner<5um | |||||
Air Oil Content:<0.1ppm | ||||||
Air Temp&Humidity:5℃~32℃ 0~50%RH | ||||||
Air Handing Capacity | 7m3/h ~ 25m3/h Pressure 5bar~7.6bar | |||||
System Pressure Dispiay | A pressão do sistema de refrigeração é medida pelo manómetro (alta pressão, baixa pressão); | |||||
A pressão do sistema circulatório é detectada por um sensor de pressão e apresentada no ecrã tátil. | ||||||
Controlador | Siemens PLC, Fuzzy PID Control algorithm. | |||||
Temp. Controlo | Control of outlet temperature | |||||
Programável | Podem ser desenvolvidos 5 procedimentos, e cada programa pode ser composto por 40 passos | |||||
Protocolo de comunicação | Ethernet Interface TCP/IP Protocol. | |||||
Internal Temp. Feedback | Equipment outlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature (water cooling equipment is configured) . | |||||
Temp. Feedback | T Temperature Sensor | |||||
Motor de compressão | Taikang,France | Taikang,France | Taikang,France | Italy Duling | Italy Duling | |
Evaporímetro | Double-pipe (heat) Exchanger | |||||
Calorifier | Flanged Barrel Heater | |||||
Acessórios de refrigeração | Danfoss / Emerson fittings (dry filters, oil separators, high and low pressure protectors, expansion valves, solenoid valves). | |||||
Painel de operações | Ecrã tátil a cores de 7 polegadas personalizado LNEYA, visualização da curva de temperatura\ exportação de dados EXCEL | |||||
Proteção segura | Com função de auto-diagnóstico; disjuntor de sequência de fases, proteção contra sobrecarga do congelador; interrutor de pressão de alta tensão, relé de sobrecarga, dispositivo de proteção térmica e outras funções de proteção de segurança. | |||||
Criogénio | Topsubmixed Refrigerant | |||||
External Insulation Hose | 8m DN32 fast coupling clamp for easy outgoing insulation hose | |||||
Refrigerante | R404A | R404A/R23 | R404A/R508B | R404A/R23/R14 | R404A/R23/R14 | |
Shape Dimension (Wind)cm | 54*69*132 | 54*69*132 | 75*73*133 | 80*120*185 | 100*150*185 | |
Shape Size (Water)cm | 54*69*132 | 54*69*132 | 75*73*133 | 70*100*175 | 80*120*185 | |
Air-Cooled Type | Copper tube aluminum fin condensation mode, upper and out type, condensing fan using Germany EBM axial flow fan. | |||||
Water-Cooled Type W | O tipo W é arrefecido a água | |||||
Water-Cooled Condenser | Sleeve type heat exchanger (Paris/ Shen’s) | |||||
Cooling Water Quantity At 25℃ | 0.6m3/h | 1.2m3/h | 1.6m3/h | 2,6m3/h | 3m3/h | |
Fonte 380V 50HZ | 3.7kW max | 5kW máx. | 5kW máx. | 6.8kW max | 7,5kW máx. | |
Fonte | Personalizável 460V 60HZN 220V 60HZ trifásico | |||||
Material da casca | Cold rolled sheet spray (Standard Colour 7035). | |||||
Temp. Spread | High Temperature To +300℃ |
Descrições
The output airflow cover of the testing machine will be covered bythe test product to form a test chamber with a relatively closedspace. The high or low temp airflow output by the testing machinewill cause the surface temp of the test product to change drastically,thus completing the corresponding high and low temp impact test.
It can isolate one lC or original component among many componentsand separately perform high and low tempimpact withoutaffecting other surrounding devices. Compared with the traditionalthermal shock test box, the temp impact rate is faster.
Provides accurate and fast ambient temperature (-120 °C ~ +300 °C) for chips, modules, integrated circuit boards, and electronic components. It is an indispensable instrument for product electrical performance testing, failure analysis, and reliability assessment.
Widely used in semiconductor companies, aerospace, optical communications, universities, research institutes and other fields.
Compared to the traditional thermostat, there are several features:
Temperature range: -120 °C ~ +300 °C;
The temperature rise and fall is very fast, -55 °C ~ 150 °C < 10 seconds;
Temperature control accuracy: ±1 °C;
Temperature setting capability: ±0.1 °C;
Temperature display capability: ±0.1 °C;
Maximum air flow: 25m3/h;
Real-time monitoring of the real temperature of the IC under test to achieve closed-loop feedback and adjust the gas temperature in real time;
The temperature rise and fall time is controllable, programmable operation, manual operation and remote control.



SOLICITAR UM ORÇAMENTO
Recommended products
FLTZ Double Frequency Conversion Series
Model FLTZ-305W FLTZ-305W/2T Double System Temp Range -30℃~40℃ -30℃~40℃ -30℃~40℃ Temp control accuracy ±0.1℃ ±0.1℃ ±0.1℃ Flow Control 15~45L/min ±0.3 15~45L/min ±0.3 15~45L/min ±0.3 Pump Pressure 6bar m…
Série FLTZ Multi-canal
Heating method within 40 ℃ adopts a compressor hot gas heating fully enclosed design, and the machine operates continuously for 24 hours Mainly used for precise temperature control in semiconductor prod…
Refrigerador de permuta de calor ETCU
Temp Range:+5℃~90℃ ±0.3℃ Cooling Capacity: 5kw~30kw Tank volume: 6L~15L Power: 06KW~1.6KW Heating method within 40 ℃ adopts a compressor hot gas heating fully enclosed design, and the machine operates…
carregando...
已经是到最后一篇内容了!