Pesquisar toda a estação


Centro de notícias

Multi-channel FLTZ multi-channel

Semicnductor Multi-channel Chiller

FLTZ -45℃~100℃
  • Precisão da temperatura±0.1℃
  • RefrigeranteR404A
  • Controlo do fluxo25~75/min 6bar max
  • Gama de potência380V 3kW~17kW

O método de aquecimento dentro de 40 ℃ adopta um design totalmente fechado de aquecimento a gás quente do compressor, e a máquina funciona continuamente durante 24 horas

FLTZ -20℃~90℃ Dual Channel

Modelo FLTZ-203W-2T
Pipeline Channel 1 Channel 2
Gama de temperaturas  -20℃~+90℃  -20℃~~90℃
Precisão do controlo da temperatura ±0.1℃ ±0.1℃
Capacidade de arrefecimento 4kW@-10℃ 4kW@-10℃
Capacidade de aquecimento 2kW 2kW
Heat transfer medium flow 20L/min@0.5MPa 20L/min@0.5MPa
Heat transfer medium interface ZG3/4 ZG3/4
Ambient temperature 10~35℃ 10~35℃
Ambient humidity 30~70% 30~70%
Temperatura da água de arrefecimento 15~20℃ 15~20℃
Cooling water flow 20L/min 20L/min
Circuit breaker 30A
Process temperature control Control remote target temperature based on self-created model-free self-building tree algorithm and cascade algorithm
Peso 400 kg
Dimensions 500*900*1600
FLTZ -10℃~90℃ Dual Channel

Modelo FLT-215W/ETCU-015W/ETCU-008W
Pipeline Channel 1 Channel 2 Channel 3
Gama de temperaturas  -20℃~+50℃  +30℃~+100℃  +30℃~+40℃
Precisão do controlo da temperatura ±0.1℃ ±0.1℃ ±0.1℃
Capacidade de arrefecimento 15kW@-10℃ 13kW@PCW+15℃ 8kW@PCW+10℃
Capacidade de aquecimento 2kW 6kW Pump Heat Loss
Heat transfer medium flow 30L/min@0.85MPa 30L/min@0.85MPa 20L/min@0.8MPa
Heat transfer medium interface ZG3/4 ZG3/4 ZG3/4
Ambient temperature 10~35 ℃ 10~35 ℃ 10~35 ℃
Ambient humidity 30~70% 30~70% 30~70%
Temperatura da água de arrefecimento 15~20℃ 15~20℃ 15~20℃
Cooling water flow 30L/min@15~20℃ 15L/min@15~20℃ 15L/min@15~20℃
Circuit breaker 75A
Process temperature control Control remote target temperature based on self-created model-free self-building tree algorithm and cascade algorithm
Peso 600kg
Dimensions 600*1000*1700

Modelo FLTZ-203W/2T Dual system FLTZ-305W/2T Dual system FLTZ-406W/2T Dual system
Gama de temperaturas -20℃~90℃  -30℃~90℃ -45℃~90℃
Precisão do controlo da temperatura ±0.1℃
Flow control and pressure 15~45l/min 6bar max
Aquecimento 2,5kw 2,5kw 2,5kw 2,5kw 3.5kw 3.5kw
Capacidade de arrefecimento 3KW at-15℃ 3KW at-15℃ 5KW at-15℃ 5KW at-15℃ 2.5KW at -35℃ 2.5KW at -35℃
Volume de líquido em circulação interna 5L 5L 8L 8L 8L 8L
Volume do depósito de expansão 15L 25L 25L
Heat transfer medium Fluorination, antifreeze, thermal silicone oil, etc.
Refrigerante R404A/ R448
Heat transfer medium interface ZG3/4
Interface da água de arrefecimento ZG3/4
Água de arrefecimento 50L/min at20℃ 600L/min at20℃ 50L/min at20℃
Alimentação eléctrica Three-phase220V  /  Three-phase 400V  /Three-phase 460V
Process temperature control Control remote target temperature based on self-created model-free self-building tree algorithm and cascade algorithm
FLTZ -45℃~90℃ Dual Channel

Modelo FLTZ-203W/2T dual system FLTZ-305W/2T  dual system FLTZ-406W/2T dual system
Gama de temperaturas -20℃~90℃  -30℃~90℃ -45℃~90℃
Precisão do controlo da temperatura ±0.1℃
Heat conducting medium flow rate 15~45l/min 6bar max
Capacidade de aquecimento 2.5kW 2.5kW 2.5kW 2.5kW 3,5 kW 3,5 kW
Capacidade de arrefecimento 3kW at-15℃ 3kW at-15℃ 5kW at-15℃ 5kW at-15℃ 2.5kW at -35℃ 2.5kW at -35℃
Volume do fluido da circulação interna 5L 5L 8L 8L 8L 8L
Volume do depósito de expansão 15L 25L 25L
Heat-conducting medium Fluorinated liquid, antifreeze, thermal conductive silicone oil, etc
Refrigerante R404A/ R448
Heat-conducting medium interface ZG3/4
Interface da água de arrefecimento ZG3/4
Interface da água de arrefecimento 50L/min at20℃ 600L/min at20℃ 50L/min at20℃
Potência Three phase 220V/Three phase 400V/Three phase 460V
Process temperature control The remote target temperature can be controlled by combining the self created model free self built tree
algorithm and cascade algorithm

Multi-channel independent temperature control can have separate temperature ranges, cooling and heating capabilities, heat transfer medium flow, etc. Two independent systems are used. Steam compression refrigeration or ETCU compressor-free heat exchange system can be selected according to the required temperature range. The system can use expansion tanks, condensers, cooling water systems, etc., which can effectively reduce equipment size and reduce operating steps.

Aplicações

Send us a message about the Dual channel chiller
*
*
Submeter....
Submission successful!
A submissão falhou! Tente novamente mais tarde
Erro de correio eletrónico!
Erro telefónico!

recomendar produtos

  • Mandril da série MD"      /&gt;<figcaption><span>-75℃ a 225°C Modelo MD-708 MD-712 MDL-708 Temp. Faixa -75℃~225℃ -75℃~225℃ -75℃~225℃ Precisão do controle de temperatura ±0.1℃ ±0.1℃ ±0.1℃ uniformidade de temperatura ±1℃ ±1℃ ±1℃ Planicidade ±50um ±50um ±50um ±50um Tamanho do comprimido 200mm de diâmetro d...</span></figcaption></figure></a></div><div class= Mandril da série MD

    -75℃ a 225°C Modelo MD-708 MD-712 MDL-708 Temp. Faixa -75℃~225℃ -75℃~225℃ -75℃~225℃ Precisão do controle de temperatura ±0.1℃ ±0.1℃ ±0.1℃ uniformidade de temperatura ±1℃ ±1℃ ±1℃ Planicidade ±50um ±50um ±50um ±50um Tamanho do comprimido 200mm de diâmetro d...

  • YQH 0℃~-75℃"      /&gt;<figcaption><span>Adequado para a recuperação de vários gases VOCs voláteis; Arrefecimento rápido, alta eficiência, atendendo a diferentes requisitos de temperatura de condensação, a baixa temperatura pode chegar a -75 ° C. Ele vem principalmente da limpeza, cola ...</span></figcaption></figure></a></div><div class= YQH 0℃~-75℃

    Adequado para a recuperação de vários gases VOCs voláteis; Arrefecimento rápido, alta eficiência, atendendo a diferentes requisitos de temperatura de condensação, a baixa temperatura pode chegar a -75 ° C. Ele vem principalmente da limpeza, cola ...

  • FLT-100℃~90℃"      /&gt;<figcaption><span>Refrigerador de canal único arrefecido a ar, concebido principalmente para máquinas de gravação. É utilizado para fornecer um controlo de temperatura independente para as paredes laterais da câmara.</span></figcaption></figure></a></div><div class= FLT-100℃~90℃

    Refrigerador de canal único arrefecido a ar, concebido principalmente para máquinas de gravação. É utilizado para fornecer um controlo de temperatura independente para as paredes laterais da câmara.

  • FLTZ -45℃~90℃"      /&gt;<figcaption><span>O método de aquecimento dentro de 40 ℃ adota um compressor de aquecimento a gás quente totalmente fechado, e a máquina opera continuamente por 24 horas O dispositivo de controle de temperatura de semicondutor Chiller é usado principalmente para p...</span></figcaption></figure></a></div><div class= FLTZ -45℃~90℃

    O método de aquecimento dentro de 40 ℃ adota um compressor de aquecimento a gás quente totalmente fechado, e a máquina opera continuamente por 24 horas O dispositivo de controle de temperatura de semicondutor Chiller é usado principalmente para p...