Vehicle/Battery Water Chillers – LNEYA Industrial Chillers Manufacturer Supplier https://www.lneya.com/pt Refrigerador de ar e refrigerador de água Wed, 25 Dec 2024 05:58:00 +0000 pt-PT por hora 1 https://wordpress.org/?v=6.8.2 https://www.lneya.com/wp-content/uploads/2024/05/logo-lneya-150x150.jpg Vehicle/Battery Water Chillers – LNEYA Industrial Chillers Manufacturer Supplier https://www.lneya.com/pt 32 32 Série de Conversão de Frequência KRYZ https://pt.lneya.com/cooling-heating-temperature-control-flow-system/kry-frequency-conversion-series.html https://pt.lneya.com/cooling-heating-temperature-control-flow-system/kry-frequency-conversion-series.html#respond Thu, 26 Sep 2024 02:48:59 +0000 https://www.lneya.com/?p=9722
SUNDI -10℃~150℃

KRYZ Frequency conversion series

Control Temperature and Flow -40℃~100℃
  • Capacidade de arrefecimento0.5kW~10kW
  • Capacidade de aquecimento0.5kW~10kW
  • RefrigeranteR134A/R1234yf
  • Peso115KG~300KG

Air-cooling & Water-cooling

Detalhes de configuração

Modelo KRYZ-475
KRYZ-475W
KRYZ-4A15W KRYZ-4A25W
Gama de temperaturas -40℃~+100℃
Precisão do controlo da temperatura ±0.1℃ ±0.1℃ ±0.1℃
Reação à temperatura Pt100 Pt100 Pt100
Indicação da temperatura 0.01k 0.01k 0.01k
Flow output 1~25 L/min 1~25 L/min 1~25 L/min
About traffic description When the temperature is below -30 degrees, the flow rate is controlled within 80% of the maximum value.
Flow control accuracy ±0.1 L/min ±0.1 L/min ±0.1 L/min
Pressure display Using pressure sensor, the pressure is displayed on the touch screen, and the pressure control can be adjusted from 0.2bar to 2.5bar
Heating capacity kW 7.5 15 25
Cooling capacity kW 100℃ 7.5 15 25
  20℃ 7.5 15 25
  0℃ 7.5 15 25
  -20℃ 4.5 10 16
  -35℃ 1.8 4 6.5
Compressor Inverter scroll compressor
Método de estrangulamento Válvula de expansão eletrónica
Separador de óleo Emerson
Filtro secador Danfoss
Evaporador Permutador de calor de placas
Bomba de circulação Variable frequency magnetic drive pump
Entrada, ecrã 7-inch color touch screen, PLC controller
Programming 5 programs can be compiled, each program can compile 40 steps
Communications Modbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet TCP/IP protocol
Proteção da segurança It has self-diagnosis function; refrigerator overload protection; high pressure switch, overload relay, thermal protection device, low liquid level protection, high temperature protection, sensor fault protection and other safety protection functions.
Sistema The entire system is a fully closed system. There will be no water vapor at high temperatures and no absorption of moisture in the air at low temperatures. The system will not cause pressure to rise due to high temperatures during operation, and will automatically replenish heat transfer media at low temperatures.
Refrigerante R404A/ R507C
Tamanho da interface G3/4 G3/4 G3/4
Water cooled @25℃ 2500L/H
ZG3/4
4000L/H
ZG1
6000L/H
DN32
Condensador arrefecido a água The water equipment condenser of this product adopts plate heat exchanger, which requires water supply from chiller or low hardness tap water, and requires water purification filter
Air cooled condenser Microchannel Heat Exchanger / /
Power supply 380V50HZ 14kW 25kW 38kW
Dimensões cm 55*85*175 70*100*175 80*120*185
Peso 280kg 360 kg 620kg
Standard Automatic antifreeze filling system, automatic liquid recovery system
Opcional 220V 60HZ three-phase 400V 50HZ three-phase 440V 60HZ three-phase
Opcional Temperature extended to -40℃~+135℃
Observação The external circulation pipeline should have a diameter of DN15 or DN20. The pipeline needs to be well insulated, and high-temperature resistant rubber and plastic insulation pipes can be used.
Material da casca Cold rolled sheet spraying (standard color 7035)

Modelo KRYZ-475W/2T KRYZ-4A15W/2T KRYZ-4A25W/2T
Gama de temperaturas -40℃~+100℃
Precisão do controlo da temperatura ±0.1℃ ±0.1℃ ±0.1℃
Reação à temperatura Pt100 Pt100 Pt100
Indicação da temperatura 0.01k 0.01k 0.01k
Flow output 1~25 L/min 1~25 L/min 1~25 L/min
About traffic description When the temperature is below -30 degrees, the flow rate is controlled within 80% of the maximum value.
Flow control accuracy ±0.1 L/min ±0.1 L/min ±0.1 L/min
Fluid output groups 2 groups 2 groups 2 groups
Pressure control per group 0,2bar~2,5bar 0,2bar~2,5bar 0,2bar~2,5bar
Flow Pressure Description The device can control flow or pressure independently. Different solutions are required for simultaneous control (customization required)
Heating capacity kW 7.5*2 10*2 15*2
Cooling capacity kW 100℃ 7.5*2 15*2 25*2
20℃ 7.5*2 15*2 25*2
0℃ 7.5*2 15*2 25*2
-20℃ 4.5*2 8.5*2 14*2
-35℃ 1.8*2 4*2 6.5*2
Compressor Inverter scroll compressor
Método de estrangulamento Válvula de expansão eletrónica
Separador de óleo Emerson
Filtro secador Danfoss
Evaporador Permutador de calor de placas
Bomba de circulação Variable frequency magnetic drive pump
Flow rate, pressure Electromagnetic flowmeter, pressure value 4~20mA
Entrada, ecrã 7-inch color touch screen, PLC controller
Communications Modbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet TCP/IP protocol
Proteção da segurança It has self-diagnosis function; refrigerator overload protection; high pressure switch, overload relay, thermal protection device, low liquid level protection, high temperature protection, sensor fault protection and other safety protection functions.
Sistema The entire system is a fully closed system. There will be no water vapor at high temperatures and no absorption of moisture in the air at low temperatures. The system will not cause pressure to rise due to high temperatures during operation, and will automatically replenish heat transfer media at low temperatures.
Refrigerante R404A/R507C/R125/N40 four refrigerants can be used
External output interface size There are 2 sets of inlet and outlet ports, G3/4
Water cooled @25℃ 4000L/H
ZG1
8000L/H
DN32
12000L/H
DN40
Condensador arrefecido a água The water equipment condenser of this product adopts plate heat exchanger, which requires water supply from chiller or low hardness tap water, and requires water purification filter
Dimensões cm 80*120*185 100*150*185 200*145*205
Power supply 380V50HZ 28kW 45kW 70kW
Peso 660KG 850 kg 1350kg
Standard Automatic antifreeze filling system, automatic liquid recovery system
Opcional 220V 60HZ three-phase 460V 60HZ three-phase
Opcional Temperature extended to -40℃~+135℃
Observação The external circulation pipeline should have a diameter of DN15 or DN20. The pipeline needs to be well insulated, and high-temperature resistant rubber and plastic insulation pipes can be used.
Material da casca Cold rolled sheet spraying (standard color 7035)

The equipment can meet the direct cooling/direct heating for battery pack and vehicle testing and testing. This equipment is mainly used for cooling and heating capacity testing. It uses variable frequency compressor with adjustable output; variable frequency fan with adjustable speed and heat dissipation; with high-precision temperature, pressure, flow sensors and built-in software, it can calculate heat exchange capacity in real time, automatically recycle and refill refrigerators, etc. It can meet the needs of battery packs of different sizes.

Envie-nos uma mensagem sobre o produto
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

Também pode estar interessado nestes produtos

carregando...

已经是到最后一篇内容了!

]]>
https://pt.lneya.com/cooling-heating-temperature-control-flow-system/kry-frequency-conversion-series.html/feed 0
Série de aquecimento com arrefecimento direto KRY https://pt.lneya.com/cooling-heating-temperature-control-flow-system/kry-direct-cooling-heating.html https://pt.lneya.com/cooling-heating-temperature-control-flow-system/kry-direct-cooling-heating.html#respond Wed, 18 Sep 2024 06:40:25 +0000 https://www.lneya.com/?p=9349
SUNDI -10℃~150℃

KRY direct cooling heating system

Control Temperature and Flow
  • Capacidade de arrefecimento0.5kW~10kW
  • Capacidade de aquecimento0.5kW~10kW
  • RefrigeranteR134A/R1234yf
  • Peso115KG~300KG

Air-cooling & Water-cooling

Modelo KRYZ-5W-ZLH KRYZ-5W-ZL
KRYZ-5-ZLH KRYZ-5-ZL
Cooling capacity kW 0.5~10 0.5~10
Heating capacity kW 0.5~10  
Subcooling Cooling 0k~6K Cooling 0k~6K
Heating 0k~6k. Low temperature environment 6k~20k
Superheat Cooling 3k~20k Refrigeration 3k~20k
Heating 3k~20k  
Condensing pressure control accuracy Better than ±50kpa Better than ±50kpa
Inspiratory pressure 300kpa~600kpa ±10kpa 300kpa~600kpa ±10kpa
Battery pack test environment temperature  -40℃ ~ +50℃  -40℃ ~ +50℃
Refrigerant flow metering Flow meter Flowmeter
Refrigerante R134A or R1234yf R134A or R1234yf
Método de arrefecimento Air-cooled variable frequency fan Air cooling variable frequency fan
Compressor Compressor de frequência variável da marca Compressor de frequência variável da marca
10-inch touch screen Real-time display of various temperatures, subcooling, superheat, cooling and heat exchange capacity, pressure, flow, current, voltage, key parameter curve recording Real-time display of various temperatures, subcooling, superheat, cooling and heat exchange capacity, pressure, flow, current, voltage, and key parameter curve records
Controlador Programmable PLC Programmable PLC
Communications CAN CAN
Alimentação eléctrica 380V 50HZ or 460V 60HZ 380V 50HZ or 460V 60HZ

The equipment can meet the direct cooling/direct heating for battery pack and vehicle testing and testing. This equipment is mainly used for cooling and heating capacity testing. It uses variable frequency compressor with adjustable output; variable frequency fan with adjustable speed and heat dissipation; with high-precision temperature, pressure, flow sensors and built-in software, it can calculate heat exchange capacity in real time, automatically recycle and refill refrigerators, etc. It can meet the needs of battery packs of different sizes.

Envie-nos uma mensagem sobre o produto
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

Também pode estar interessado nestes produtos

carregando...

已经是到最后一篇内容了!

]]>
https://pt.lneya.com/cooling-heating-temperature-control-flow-system/kry-direct-cooling-heating.html/feed 0
Oil Cooling Chiller KRYO Series https://pt.lneya.com/cooling-heating-temperature-control-flow-system/oil-cooling-motor-testing.html https://pt.lneya.com/cooling-heating-temperature-control-flow-system/oil-cooling-motor-testing.html#respond Wed, 18 Sep 2024 05:57:00 +0000 https://www.lneya.com/?p=9350
KRY -40℃~+100℃ (1to6)

KRYO 0℃~160℃

Oil Cooling Chiller
  • Precisão da temperatura±0.3℃
  • Flow Accuracy±0.2L/min
  • Capacidade de arrefecimento12kW~38kW
  • Heating Capacity15kW~38kW
  • Saída do caudal1~40 L/min
  • CoolantOil

The object under test is connected to a test platform adapter
The component is cooled and heated by ethylene glycol water solution
-40’C~100°C (expandable to 150°C)

 

KRYO SERIES A15W A25W A38W A15W2S A25W2S A38W2S
Gama de temperaturas 0℃ ~ +160℃ Different viscosity oils have different temperature ranges
Controlo da temperatura accuracy ±0.3℃
Reação à temperatura PT100
Controlo do fluxo 2L/min~20L/min, one in and one out, in and out control linkage 2L/min~15L/min Two outputs, one input Flow control linkage
Flow accuracy ±0.2L/min
Controlo da pressão 0.2bar~2.5bar
Heating capacity kW 15 25 38 15 25 38
Cooling capacity kW 125℃ 15 25 38 15 25 38
20℃ 12 20 30 12 20 30
Compressor Emerson Copeland Scroll Flexible Compressor/Japanese Scroll Flexible Compressor
Método de estrangulamento Válvula de expansão eletrónica
Evaporador Permutador de calor de placas
Bomba de circulação Gear Pumps
Flow regulation Inverter vector control
Entrada, ecrã 7-inch color touch screen/PLC controller
Communications CAN communication
Refrigerante R410A
Coolant Oil
Liquid inlet and outlet G3/4
Água de arrefecimento @20℃ 3000L/H 4200L/H 6200L/H 3000L/H 4200L/H 6200L/H
Ligação da água de arrefecimento G3/4 G3/4 G1 G3/4 G3/4 G1  
fonte de alimentação 380V 50HZ three-phase five-wire
Disjuntor 50A 80A 125A 50A 80A 125A
External tooling External oil return tooling size 600×850×600
If the external oil return fixture is selected, the fixture needs to be installed under the test motor.
Request a quotation about oil cooling chiller
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

recomendar produtos

carregando...

已经是到最后一篇内容了!

]]>
https://pt.lneya.com/cooling-heating-temperature-control-flow-system/oil-cooling-motor-testing.html/feed 0
KRY -40℃~+100℃ (1to6) https://pt.lneya.com/cooling-heating-temperature-control-flow-system/glycol-refrigeration-heating-test-system-kry.html https://pt.lneya.com/cooling-heating-temperature-control-flow-system/glycol-refrigeration-heating-test-system-kry.html#respond Sun, 17 Sep 2023 08:03:13 +0000 https://www.lneya.com/special-chiller/glycol-refrigeration-heating-test-system-kry.html
KRY -40℃~+100℃ (1to6)
KRY -40℃~+100℃ (1to6)
KRY -40℃~+100℃ (1to6)
KRY -40℃~+100℃ (1to6)

KRY -40℃~100℃ 1&6S

Simulação da temperatura de ensaio do anticongelante do veículo
  • Potência de aquecimento15kW~38kW
  • Capacidade de arrefecimento10kW~60kW
  • Gama de potência36kW~8kW
  • Precisão da temperatura±0.5℃
  • Saída do caudal1~40 L/min
  • RefrigeranteR404A/R507C
  • Peso250KG~1300KG

Descarregamento de dados do produto

Controlo da temperatura no processo de ensaio de componentes de veículos movidos a novas energias

controlo da temperatura, controlo do fluxo

Os componentes são arrefecidos e aquecidos internamente através de uma solução aquosa de etilenoglicol para ensaio

-40 ° C~100 ° C (expansível até 150 ° C)

Parâmetros pormenorizados

Modelo Unidade Synbol KRY-4A25W/6S KRY-4A38W/6S KRY-4A60W/6S
Gama de temperaturas  -40℃~+100℃
Saída do caudal L/min 1~20  1~20  1~40 
Precisão do caudal  L/min ±0.2
Potência de aquecimento kW 15 25 38
Capacidade de arrefecimento 100℃ 25kW 38kW 60kW
200℃ 25kW 38kW 60kW
0℃ 25kW 38kW 60kW
 -35℃ 5kW 8kW 13kW
Refrigerante   R404A/R507C/R125/N40
Potência 380V50HZ kW máx 38 55 82
Dimensão (L) cm        
Dimensão (A) cm 120*180*205 145*205*225 145*205*225
Peso (arrefecimento a água) KG 900 1200 1950
Modo de controlo Feedback PID + O nosso cálculo de controlo dinâmico especial, controlador PLC
Controlo da temperatura Controlo da temperatura do processo e modelo de controlo da temperatura da camisa
Diferença de temperatura Definir ou controlar a diferença de temperatura entre o óleo de revestimento e o processo da matéria-prima
Editor de programas 10 programas, cada programa pode editar 40 passos
Protocolo de comunicação Protocolo MODBUS RTU, interface RS485
Feedback da temperatura do material PT100 OU 4~20mA ou comunicação(normal: PT100)
Feedback da temperatura A temperatura de três pontos: a entrada e a saída do equipamento, a temperatura do material do reator (sensor de temperatura externo)
Válvula de expansão Válvula de expansão térmica Emerson/válvula de expansão térmica Danfoss
Evaporador DANFOSS/KAORI Permutador de calor de placas
Painel de operações Ecrã tátil de 7 polegadas , mostrar curva de temperatura \ saída de dados EXCEL
Proteção de segurança Função de auto-diagnóstico; proteção contra sobrecarga do congelador; interrutor de alta pressão, relé de sobrecarga, dispositivo de proteção térmica, proteção de nível baixo de líquido, proteção de temperatura elevada e proteção contra falhas de temperatura.
Sistema de circulação fechado Todo o sistema é de circulação totalmente fechada, não há névoa de óleo a alta temperatura e não há vapor de água a baixa temperatura, a pressão não sobe quando o sistema está a funcionar. O sistema fornecerá óleo automaticamente a baixa temperatura.
Refrigerante R404A/R507C/R125/N40 Estão disponíveis todos os quatro fluidos frigorigéneos

Descrição do produto

Clique na mensagem online para obter informações sobre os detalhes do produto
Pedir informações sobre KRY -40℃ 1&6
Pedir informações sobre KRY -40℃ 1&6
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

recomendar produtos

    carregando...

    已经是到最后一篇内容了!

    ]]>
    https://pt.lneya.com/cooling-heating-temperature-control-flow-system/glycol-refrigeration-heating-test-system-kry.html/feed 0
    KRY -40℃~+100℃ (1 para 1) https://pt.lneya.com/cooling-heating-temperature-control-flow-system/new-energy-vehicle-motor-test-equipment.html https://pt.lneya.com/cooling-heating-temperature-control-flow-system/new-energy-vehicle-motor-test-equipment.html#respond Sun, 17 Sep 2023 07:50:24 +0000 https://www.lneya.com/special-chiller/new-energy-vehicle-motor-test-equipment.html
    KRY -40℃~+100℃ (1 para 1)
    KRY -40℃~+100℃ (1 para 1)
    KRY -40℃~+100℃ (1 para 1)
    KRY -40℃~+100℃ (1 para 1)

    Battery Cooling Chiller/Hydrogen Cooling Chiller

    KRY -40℃~100℃ 1&1
    • Potência de aquecimento5.5kW~60kW
    • Capacidade de arrefecimento1.2kW~60kW
    • Gama de potência10kW~84kW
    • Precisão da temperatura±0.5℃
    • Saída do caudal1~40 L/min
    • RefrigeranteR404A/R507C
    • Peso250KG~1300KG

    Parâmetros pormenorizados

    KRY Unidade Synbol 455/455W K475 4A10/4A10W 4A15/4A15W 4A25/4A25W 4A38W 4A60W
    Gama de temperaturas  -40℃~+100℃
    Saída do caudal L/min 1~10 L/min 1~25 L/min 1~25 L/min 1~40 L/min 1~40 L/min 5~50 L/min 5~50L/min
    Precisão do caudal  L/min ±0,2 L/min
    Potência de aquecimento kW 5,5 kW 7,5 kW 10kW 10kW/Opcional 15kW 15kW/Opcional 25kW 25kW/Opcional 38kW 38kW/Opcional 60kW
    Capacidade de arrefecimento 100℃ 5,5 kW 7,5 kW 10kW 15kW 25kW 38kW 60kW
    200℃ 5,5 kW 7,5 kW 10kW 15kW 25kW 38kW 60kW
    0℃ 5,5 kW 7,5 kW 10kW 15kW 25kW 38kW 60kW
     -35℃ 1,2kW 1,8kW 2.5kW 4kW 6,5 kW 10kW 15kW
    Refrigerante   R404A/ R507C
    Potência 380V50HZ kW máx 12kW máx. 15kW máx. 20kW máx. 29kW máximo 42kW máximo 58kW máximo 84kW máximo
    Dimensão (L) cm (W) cm 55*95*175 55*95*175 55*95*175 70*100*175 80*120*185 100*150*185 145*205*205
    Dimensão (A) cm (A) cm 55*95*175 55*95*175 70*100*175 80*120*185 100*150*185    

    Peso (arrefecimento a água)

    KG 250KG 280KG 320KG 360KG 620KG 890KG 1300KG
    Modo de controlo Feedback PID + O nosso cálculo de controlo dinâmico especial, controlador PLC
    Controlo da temperatura Controlo da temperatura do processo e modelo de controlo da temperatura da camisa
    Diferença de temperatura Definir ou controlar a diferença de temperatura entre o óleo de revestimento e o processo da matéria-prima
    Editor de programas 10 programas, cada programa pode editar 40 passos
    Protocolo de comunicação Protocolo MODBUS RTU, interface RS485
    Feedback da temperatura do material PT100 OU 4~20mA ou comunicação(normal: PT100)
    Feedback da temperatura A temperatura de três pontos: a entrada e a saída do equipamento, a temperatura do material do reator (sensor de temperatura externo)
    Válvula de expansão Válvula de expansão térmica Emerson/válvula de expansão térmica Danfoss
    Evaporador DANFOSS/KAORI Permutador de calor de placas
    Painel de operações Ecrã tátil de 7 polegadas , mostrar curva de temperatura \ saída de dados EXCEL
    Proteção de segurança Função de auto-diagnóstico; proteção contra sobrecarga do congelador; interrutor de alta pressão, relé de sobrecarga, dispositivo de proteção térmica, proteção de nível baixo de líquido, proteção de temperatura elevada e proteção contra falhas de temperatura.
    Sistema de circulação fechado Todo o sistema é de circulação totalmente fechada, não há névoa de óleo a alta temperatura e não há vapor de água a baixa temperatura, a pressão não sobe quando o sistema está a funcionar. O sistema fornecerá óleo automaticamente a baixa temperatura.
    Refrigerante R404A/R507C/R125/N40  All four refrigerants are available

    A faixa de temperatura é de -40 ℃ ~ + 100 ℃, que pode ser estendida para + 135 ℃ de acordo com a situação real, e a precisão do controle de temperatura é mais ou menos 0,5 ℃. O equipamento pode controlar o fluxo e a pressão de forma independente enquanto controla a temperatura, e diferentes soluções personalizadas são necessárias para o controle simultâneo.


    O objeto testado é ligado a um adaptador de plataforma de teste.
    O interior da peça foi arrefecido e aquecido por uma solução aquosa de etilenoglicol.
    O componente de ensaio tem de passar por um perfil de temperatura específico e registar as alterações de temperatura.
    As variações de temperatura variam normalmente entre -40 ℃ e 100 ℃ (expansível até 150 ℃)
    Ao efetuar um teste de tolerância, é normalmente necessário um ciclo infinito.



    此图片的 alt 属性为空;文件名为 03_1588131509-1.jpg

    *
    *

    Multicanal

    Canal 1Canal 2Canal 3

    Tensão

    50HZ monofásico50HZ trifásico60HZ monofásico60HZ trifásico*
    Submeter....
    Enviado com sucesso!
    A submissão falhou! Tente novamente mais tarde
    Erro de correio eletrónico!
    Erro telefónico!

    Cooling Water Chiller:

    • Used to control the temperature of the battery pack to ensure that the battery pack can be kept within the specified temperature range during the test.
    • Can simulate the performance of the battery pack under different temperature conditions, such as low temperature start-up, high temperature operation, etc.

    Heating System:

    • When it is necessary to simulate a high temperature environment, the heating system can be used in conjunction with the cooling water circulation machine to ensure that the battery pack can operate under high temperature conditions.

    Environmental Simulation Chamber:

    • Provides a closed space for simulating different environmental conditions, such as temperature, humidity, air pressure, etc.
    • The interior of the environmental simulation box/chamber is usually equipped with monitoring equipment such as temperature sensors and humidity sensors, as well as control equipment such as heaters and humidifiers.

    recomendar produtos

    carregando...

    已经是到最后一篇内容了!

    ]]>
    https://pt.lneya.com/cooling-heating-temperature-control-flow-system/new-energy-vehicle-motor-test-equipment.html/feed 0
    KRY -40℃~+100℃ (1to2) https://pt.lneya.com/cooling-heating-temperature-control-flow-system/electric-car-chiller.html https://pt.lneya.com/cooling-heating-temperature-control-flow-system/electric-car-chiller.html#respond Sun, 17 Sep 2023 07:50:21 +0000 https://www.lneya.com/special-chiller/electric-car-chiller.html
    KRY -40℃~+100℃ (1to2)
    KRY -40℃~+100℃ (1to2)
    KRY -40℃~+100℃ (1to2)
    KRY -40℃~+100℃ (1to2)
    KRY -40℃~+100℃ (1to2)

    KRY -40℃~100℃ 1&2S

    Simulação da temperatura de ensaio do anticongelante do veículo
    • Potência de aquecimento10kW~38kW
    • Capacidade de arrefecimento2.5kW~60kW
    • Gama de potência17kW~81kW
    • Precisão da temperatura±0.5℃
    • Saída do caudal1~40 L/min
    • RefrigeranteR404A/R507C/R125/N40
    • Peso360KG~1750KG

    Descarregamento de dados do produto

    A faixa de temperatura é de -40 ℃ ~ + 100 ℃, que pode ser estendida para + 135 ℃ de acordo com a situação real, e a precisão do controle de temperatura é mais ou menos 0,5 ℃. O equipamento pode controlar o fluxo e a pressão de forma independente enquanto controla a temperatura, e diferentes soluções personalizadas são necessárias para o controle simultâneo.


    O objeto testado é ligado a um adaptador de plataforma de teste.
    O interior da peça foi arrefecido e aquecido por uma solução aquosa de etilenoglicol.
    O componente de ensaio tem de passar por um perfil de temperatura específico e registar as alterações de temperatura.
    As variações de temperatura variam normalmente entre -40 ℃ e 100 ℃ (expansível até 150 ℃)
    Ao efetuar um teste de tolerância, é normalmente necessário um ciclo infinito.

    Parâmetros pormenorizados

    Modelo Unidade Synbol KRY-475/475W/2S KRY-4A15W/2S KRY-4A25W/2S KRY-4A38W/2S KRY-4A60W/2S
    Gama de temperaturas  -40℃~+100℃
    Saída do caudal L/min 1~20 L/min 1~20 L/min 1~20 L/min 1~40 L/min 1~40 L/min
    Precisão do caudal  L/min ±0,2 L/min
    Potência de aquecimento kW 7,5 kW 10kW 15kW 25kW 38kW
    Capacidade de arrefecimento 100℃ 10kW 15kW 25kW 38kW 60kW
    200℃ 10kW 15kW 25kW 38kW 60kW
    0℃ 10kW 15kW 25kW 38kW 60kW
     -35℃ 2.5kW 4kW 6,5 kW 10kW 15kW
    Refrigerante   R404A/R507C/R125/N40
    Potência 380V50HZ kW máx 16,5 kW 24kW máx. 36kW máx. 56kW max 81kW max
    Dimensão (A) cm (A) cm 70*100*175 80*120*185 100*150*185 120*180*205 145*205*225
    Peso (arrefecimento a água) KG 360KG 450KG 750KG 1000KG 1700KG
    Modelo Unidade Synbol KRY-455/455W KRY-475 KRY-4A10/4A10W KRY-4A15/4A15W KRY-4A25/4A25W KRY-4A38W KRY-4A60W
    Gama de temperaturas  -40℃~+100℃
    Saída do caudal L/min 1~10 L/min 1~25 L/min 1~25 L/min 1~40 L/min 1~40 L/min 5~50 L/min 5~50L/min
    Precisão do caudal  L/min ±0,2 L/min
    Potência de aquecimento kW 5,5 kW 7,5 kW 10kW 10kW/Opcional 15kW 15kW/Opcional 25kW 25kW/Opcional 38kW 38kW/Opcional 60kW
    Capacidade de arrefecimento 100℃ 5,5 kW 7,5 kW 10kW 15kW 25kW 38kW 60kW
    200℃ 5,5 kW 7,5 kW 10kW 15kW 25kW 38kW 60kW
    0℃ 5,5 kW 7,5 kW 10kW 15kW 25kW 38kW 60kW
     -35℃ 1,2kW 1,8kW 2.5kW 4kW 6,5 kW 10kW 15kW
    Refrigerante   R404A/ R507C
    Potência 380V50HZ kW máx 12kW máx. 15kW máx. 20kW máx. 29kW máximo 42kW máximo 58kW máximo 84kW máximo
    Dimensão (L) cm (W) cm 55*95*175 55*95*175 55*95*175 70*100*175 80*120*185 100*150*185 145*205*205
    Dimensão (A) cm (A) cm 55*95*175 55*95*175 70*100*175 80*120*185 100*150*185    

    Peso (arrefecimento a água)

    KG 250KG 280KG 320KG 360KG 620KG 890KG 1300KG
    Modo de controlo Feedback PID + O nosso cálculo de controlo dinâmico especial, controlador PLC
    Controlo da temperatura Controlo da temperatura do processo e modelo de controlo da temperatura da camisa
    Diferença de temperatura Definir ou controlar a diferença de temperatura entre o óleo de revestimento e o processo da matéria-prima
    Editor de programas 10 programas, cada programa pode editar 40 passos
    Protocolo de comunicação Protocolo MODBUS RTU, interface RS485
    Feedback da temperatura do material PT100 OU 4~20mA ou comunicação(normal: PT100)
    Feedback da temperatura A temperatura de três pontos: a entrada e a saída do equipamento, a temperatura do material do reator (sensor de temperatura externo)
    Válvula de expansão Válvula de expansão térmica Emerson/válvula de expansão térmica Danfoss
    Evaporador DANFOSS/KAORI Permutador de calor de placas
    Painel de operações Ecrã tátil de 7 polegadas , mostrar curva de temperatura \ saída de dados EXCEL
    Proteção de segurança Função de auto-diagnóstico; proteção contra sobrecarga do congelador; interrutor de alta pressão, relé de sobrecarga, dispositivo de proteção térmica, proteção de nível baixo de líquido, proteção de temperatura elevada e proteção contra falhas de temperatura.
    Sistema de circulação fechado Todo o sistema é de circulação totalmente fechada, não há névoa de óleo a alta temperatura e não há vapor de água a baixa temperatura, a pressão não sobe quando o sistema está a funcionar. O sistema fornecerá óleo automaticamente a baixa temperatura.
    Refrigerante R404A/R507C/R125/N40 Estão disponíveis todos os quatro fluidos frigorigéneos

    Descrição do produto


    Para a gestão do carregamento da bateria, o dispositivo de controlo de temperatura de precisão para testar o motor síncrono de ímanes permanentes, o motor de relutância comutada, o motor assíncrono e o seu controlador podem realizar o modo de controlo local + remoto através do painel de controlo de cristais líquidos;


    Com função de proteção automática contra falhas, pode emitir sinais correspondentes para garantir a segurança do equipamento. As peças principais são todas de marcas internacionais, garantia de qualidade, tratamento de pulverização eletrostática de alta pressão na superfície, e o equipamento auxiliar pode ser adicionado de acordo com as necessidades específicas.



    Clique na mensagem online para obter informações sobre os detalhes do produto
    Send us a message about KRY -40℃ 1 with 2s
    *
    *
    正在提交中....
    提交成功!
    提交失败!请稍后再试
    邮箱错误!
    电话错误!

    Também pode estar interessado nestes produtos

    carregando...

    已经是到最后一篇内容了!

    ]]>
    https://pt.lneya.com/cooling-heating-temperature-control-flow-system/electric-car-chiller.html/feed 0
    KRY -40℃~+100℃ (1to3) https://pt.lneya.com/cooling-heating-temperature-control-flow-system/control-flow-control-pressure-refrigeration-heating-system-kry.html https://pt.lneya.com/cooling-heating-temperature-control-flow-system/control-flow-control-pressure-refrigeration-heating-system-kry.html#respond Sun, 17 Sep 2023 07:50:17 +0000 https://www.lneya.com/special-chiller/control-flow-control-pressure-refrigeration-heating-system-kry.html
    KRY -40℃~+100℃ (1to3)
    KRY -40℃~+100℃ (1to3)
    KRY -40℃~+100℃ (1to3)
    KRY -40℃~+100℃ (1to3)

    KRY -40℃~100℃ 1&3S

    Simulação da temperatura de ensaio do anticongelante do veículo
    • Potência de aquecimento15kW~38kW
    • Capacidade de arrefecimento4kW~60kW
    • Gama de potência23.5kW~82kW
    • Precisão da temperatura±0.5℃
    • Saída do caudal1~40 L/min
    • RefrigeranteR404A/R507C/R125/N40
    • Peso420KG~1700KG

    KRY -40℃~100℃ 1&3S (3 sets of auxiliary temperature control, Pressure/Flow controlled separately)

     

    KRY Unidade Synbol 4A15W/3S 4A25W/3S 4A38W/3S 4A60W/3S 4A25W/6S 4A38W/6S 4A60W/6S
    Gama de temperaturas  -40℃~+100℃
    Saída do caudal L/min 1~20 1~20  1~20  1~40  1~20  1~20  1~40 
    Precisão do caudal  L/min ±0,2 L/min
    Potência de aquecimento kW 10kW 15kW 25kW 38kW 15kW 25kW 38kW
    Capacidade de arrefecimento 100℃ 15kW 25kW 38kW 60kW 25kW 38kW 60kW
    200℃ 15kW 25kW 38kW 60kW 25kW 38kW 60kW
    0℃ 15kW 25kW 38kW 60kW 25kW 38kW 60kW
     -35℃ 4kW 6,5 kW 10kW 15kW 5kW 8kW 13kW
    Refrigerante   R404A/R507C/R125/N40
    Potência 380V50HZ kW máx 23.5kW max 36kW máx. 55kW max 82kW max 38kW max 55kW max 82kW max

    Dimensão (A) cm

    (A) cm 80*120*185 100*150*185 120*180*205 145*205*225 120*180*205 145*205*225 145*205*225
    Peso (arrefecimento a água) KG 420KG 750KG 1000KG 1700KG 900KG 1200KG 1950KG
    Modo de controlo Feedback PID + O nosso cálculo de controlo dinâmico especial, controlador PLC
    Controlo da temperatura Controlo da temperatura do processo e modelo de controlo da temperatura da camisa
    Diferença de temperatura Definir ou controlar a diferença de temperatura entre o óleo de revestimento e o processo da matéria-prima
    Editor de programas 10 programas, cada programa pode editar 40 passos
    Protocolo de comunicação Protocolo MODBUS RTU, interface RS485
    Feedback da temperatura do material PT100 OU 4~20mA ou comunicação(normal: PT100)
    Feedback da temperatura A temperatura de três pontos: a entrada e a saída do equipamento, a temperatura do material do reator (sensor de temperatura externo)
    Válvula de expansão Válvula de expansão térmica Emerson/válvula de expansão térmica Danfoss
    Evaporador DANFOSS/KAORI Permutador de calor de placas
    Painel de operações Ecrã tátil de 7 polegadas , mostrar curva de temperatura \ saída de dados EXCEL
    Proteção de segurança Função de auto-diagnóstico; proteção contra sobrecarga do congelador; interrutor de alta pressão, relé de sobrecarga, dispositivo de proteção térmica, proteção de nível baixo de líquido, proteção de temperatura elevada e proteção contra falhas de temperatura.
    Sistema de circulação fechado Todo o sistema é de circulação totalmente fechada, não há névoa de óleo a alta temperatura e não há vapor de água a baixa temperatura, a pressão não sobe quando o sistema está a funcionar. O sistema fornecerá óleo automaticamente a baixa temperatura.
    Refrigerante R404A/R507C/R125/N40  All four refrigerants are available

    Descrição do produto

    A faixa de temperatura é de -40 ℃ ~ + 100 ℃, que pode ser estendida para + 135 ℃ de acordo com a situação real, e a precisão do controle de temperatura é mais ou menos 0,5 ℃. O equipamento pode controlar o fluxo e a pressão de forma independente enquanto controla a temperatura, e diferentes soluções personalizadas são necessárias para o controle simultâneo.


    O objeto testado é ligado a um adaptador de plataforma de teste.
    O interior da peça foi arrefecido e aquecido por uma solução aquosa de etilenoglicol.
    O componente de ensaio tem de passar por um perfil de temperatura específico e registar as alterações de temperatura.
    As variações de temperatura variam normalmente entre -40 ℃ e 100 ℃ (expansível até 150 ℃)
    Ao efetuar um teste de tolerância, é normalmente necessário um ciclo infinito.


    Multi-channel temperature flow control, one device can achieve multi-channel output, each channel can control different flows without interference with each other.

    Fully closed pipe design, high efficiency plate heat exchanger, used for lifting temperature and constant temperature control in new energy battery and motor test, especially suitable for heat and heat release process control during test.







    Send us a message about KRY series Multi-channel chiller
    *
    *
    Submitting…
    Submissão bem sucedida!
    Submission failed! Please try again later~
    Erro de correio eletrónico!
    Erro telefónico!

    Também pode estar interessado nestes produtos

    carregando...

    已经是到最后一篇内容了!

    ]]>
    https://pt.lneya.com/cooling-heating-temperature-control-flow-system/control-flow-control-pressure-refrigeration-heating-system-kry.html/feed 0
    KRY 0℃~+100℃ (1to2) https://pt.lneya.com/cooling-heating-temperature-control-flow-system/kry-2.html https://pt.lneya.com/cooling-heating-temperature-control-flow-system/kry-2.html#respond Wed, 17 May 2023 08:02:32 +0000 https://www.lneya.com/special-chiller/kry-2.html
    KRY 0℃~+100℃(1&2)
    KRY 0℃~+100℃(1&2)
    KRY 0℃~+100℃(1&2)
    KRY 0℃~+100℃(1&2)

    KRY 0℃~100℃ 1&2S

    Normal temperature chiller for vehicle antifreeze test
    • Potência de aquecimento10kW~38kW
    • Capacidade de arrefecimento7kW~60kW
    • Gama de potência17kW~65kW
    • Precisão da temperatura±0.5℃
    • Saída do caudal2~50 L/min
    • RefrigeranteR404A/R507C/R125/N40
    • Peso360KG~1700KG

    Parâmetros Descrição

    Modelo KRY-75/2S KRY-A15/2S KRY-A25W/2S KRY-A38W/2S KRY-A60W/2S
    KRY-75W/2S KRY-A15W/2S
    Temp. Gama 0℃~+100℃
    Precisão do controlo da temperatura ±0.5℃ ±0.5℃ ±0.5℃ ±0.5℃ ±0.5℃
    Feedback da temperatura Pt100 Pt100 Pt100 Pt100 Pt100
    Indicação da temperatura 0.01k 0.01k 0.01k 0.01k 0.01k
    Controlo de fluxo/Grupo 2~25 L/min 2~25 L/min 2~25L/min 5~50 L/min 5~50 L/min
    Precisão do controlo do caudal/Grupo ±0.2L ±0.2L ±0.2L ±0.2L ±0.2L
    Número de grupos de saída de fluido 2 Groups 2 Groups 2 Groups 2 Groups 2 Groups
    controlo da pressão/Grupo 0,2bar~2,5bar 0,2bar~2,5bar 0,2bar~2,5bar 0,2bar~2,5bar 0,2bar~2,5bar
    descrição da pressão do caudal O equipamento pode controlar o caudal e a pressão separadamente. É necessário controlar ao mesmo tempo utilizando soluções diferentes (a personalizar)
    Potência de aquecimento 10kW 10kW 15kW 25kW 38kW
    capacidade de arrefecimento 100℃ 10kW 15kW 25kW 38kW 60kW
    20℃ 10kW 15kW 25kW 38kW 60kW
    5℃ 7kW 11kW 18kW 27kW 42kW
    compressão Compressor de roda Emerson Valley
    expansão Danfoss  Thermal Expansion Valve/ Emerson Solenoid
    distribuidor de óleo Emerson
    Filtro seco, Pressão Emerson/Danfoss
    Evaporador Permutador de calor de placas
    Bomba de circulação Magnetic pump
    Frequência Delta
    Fluxo, sensor de pressão Medidor de caudal de marca alemã, pressão da johnson Controls
    entrada, ecrã 5 inch color touch screen \ Siemens S7-1200 PLC controller
    Comunicação Protocolo Modbus RTU Interface RS485, barramento de comunicação CAN opcional, interface Ethernet Protocolo TCP/IP
    Proteção de segurança Com função de auto-diagnóstico; Proteção contra sobrecarga do frigorífico; Interruptor de alta pressão, relé de sobrecarga, proteção térmica
    dispositivo, proteção contra nível baixo de líquido, proteção contra temperaturas elevadas, proteção contra falhas do sensor e outras funções de segurança
    refrigerante R404A/R507C/R125/N40 All four refrigerants are available
    Tamanho da ligação There are two groups of inlet and outlet,G3/4
    Água de arrefecimento a 20C° 2600L/H 3200L/H 6000L/H 9000L/H 15000L/H
    Condensador(W) Permutador de calor de tipo tubular Shenshi
    Potência 380V50HZ 17kW 20kW 31kW 43kW 65kW
    Dimensão cm 70*100*175 80*120*185 100*150*185 120*180*205 145*205*225
    Peso 360KG 450kg 750 kg 1000kg 1700kg
    Opcional 220V 60HZ trifásico 460V 60H trifásico

    Descrição do produto

    A faixa de temperatura é de -40 ℃ ~ + 100 ℃, que pode ser estendida para + 135 ℃ de acordo com a situação real, e a precisão do controle de temperatura é mais ou menos 0,5 ℃. O equipamento pode controlar o fluxo e a pressão de forma independente enquanto controla a temperatura, e diferentes soluções personalizadas são necessárias para o controle simultâneo.

       Equipada com uma bomba de circulação potente, garante o fornecimento de líquidos altamente viscosos.
      Controlar a saída de fluxo com regulação de frequência variável ou válvula de controlo proporcional para obter um controlo de alta precisão, com ajuste da gama total 5%~100%.



    Temperatura de ensaio dos principais itens de ensaio da eletrónica do veículo:


       Condições de ensaio do CI para locomotivas: -40℃~125℃, vento soprando, exposição ao sol, alta vibração;
       Condições de teste de funcionamento do painel de instrumentos: -40℃~85℃;
      Condições de teste do controlador do motor: temperatura de teste operacional: 40 ℃ ~ 110 ℃;
    Posicionamento por satélite (GPS) Condições de teste: temperatura de teste de operação de alta temperatura: 85 ℃; temperatura de teste de operação de baixa temperatura: -40 ℃;
      Vibração composta: -40℃~80℃;
      É evidente que a melhor solução é que a casa de ensaios disponha de um equipamento de simulação de temperatura.

    Clique na mensagem online para obter informações sobre os detalhes do produto
    Send us a message about KRY 0℃ 1&2
    Send us a message about KRY 0℃ 1&2
    *
    *
    正在提交中....
    提交成功!
    提交失败!请稍后再试
    邮箱错误!
    电话错误!

    Também pode estar interessado nestes produtos

      carregando...

      已经是到最后一篇内容了!

      ]]>
      https://pt.lneya.com/cooling-heating-temperature-control-flow-system/kry-2.html/feed 0
      KRY 0℃~+100℃ (1a3) https://pt.lneya.com/cooling-heating-temperature-control-flow-system/kry-3.html https://pt.lneya.com/cooling-heating-temperature-control-flow-system/kry-3.html#respond Wed, 17 May 2023 08:02:29 +0000 https://www.lneya.com/special-chiller/kry-3.html
      KRY 0℃~+100℃(1&3)
      KRY 0℃~+100℃(1&3)
      KRY 0℃~+100℃(1&3)
      KRY 0℃~+100℃(1&3)
      KRY 0℃~+100℃(1&3)

      KRY 0℃~100℃ 1&3S

      Simulação da temperatura de ensaio do anticongelante do veículo
      • Potência de aquecimento5.5kW~60kW
      • Capacidade de arrefecimento11kW~60kW
      • Gama de potência22kW~68kW
      • Precisão da temperatura±0.5℃
      • Saída do caudal1~40 L/min
      • RefrigeranteR404A/R507C
      • Peso420KG~1700KG

      KRY 0℃~100℃ 1&3S (3 sets of auxiliary temperature control, pressure/flow controlled separately)

      Modelo KRY-A15W/3S KRY-A25W/3S KRY-A38W/3S KRY-A60W/3S
      KRY-A15/3S KRY-A25/3S
      Temp. Gama 0℃~+100℃
      Precisão do controlo da temperatura ±0.5℃ ±0.5℃ ±0.5℃ ±0.5℃
      Feedback da temperatura Pt100 Pt100 Pt100 Pt100
      Indicação da temperatura 0.01k 0.01k 0.01k 0.01k
      Controlo de fluxo/Grupo 2~25 L/min 2~25 L/min 2~25 L/min 1~25 L/min
      Precisão do controlo do caudal/Grupo ±0.2L ±0.2L ±0.2L ±0.2L
      Número de grupos de saída de fluido 3 Groups 3 Groups 3 Groups 3 Groups
      controlo da pressão/Grupo 0,2bar~2,5bar 0,2bar~2,5bar 0,2bar~2,5bar 0,2bar~2,5bar
      descrição da pressão do caudal O equipamento pode controlar o caudal e a pressão separadamente. É necessário controlar ao mesmo tempo utilizando soluções diferentes (a personalizar)
      Potência de aquecimento 10kW 15kW 25kW 38kW
      capacidade de arrefecimento 100℃ 15kW 25kW 38kW 60kW
      20℃ 15kW 25kW 38kW 60kW
      5℃ 11kW 18kW 27kW 42kW
      compressão Compressor de roda Emerson Valley
      expansão Danfoss  Thermal Expansion Valve/ Emerson Solenoid
      distribuidor de óleo Emerson
      Filtro seco, Pressão Danfoss
      Evaporador Permutador de calor de placas
      Bomba de circulação A bomba centrífuga Nangfang pode ser selecionada com a bomba magnética de marca importada
      Frequência Delta
      Fluxo, sensor de pressão Medidor de caudal de marca alemã, pressão da johnson Controls
      entrada, ecrã Ecrã tátil a cores de 7 polegadas \ Controlador PLC
      Comunicação Protocolo Modbus RTU Interface RS485, barramento de comunicação CAN opcional, interface Ethernet Protocolo TCP/IP
      Proteção de segurança Com função de auto-diagnóstico; Proteção contra sobrecarga do frigorífico; Interruptor de alta pressão, relé de sobrecarga, proteção térmica
      dispositivo, proteção contra nível baixo de líquido, proteção contra temperaturas elevadas, proteção contra falhas do sensor e outras funções de segurança
      refrigerante R404A/R507C/R125/N40 All four refrigerants are available
      Tamanho da ligação There are three groups of inlet and outlet,ZG3/4
      Água de arrefecimento a 20C° 3200L/H 6000L/H 9000L/H 15000L/H
      Condensador(W) Permutador de calor de tipo tubular Shenshi
      Potência 380V50HZ 22kW 33kW 45kW 68kW
      Dimensão cm 80*120*185 100*150*185 100*150*185 100*150*185
      Peso 420kg 750 kg 1000kg 1700kg
      Opcional 220V 60HZ three phase    460V 60H three phase
      Opcional O tamanho da tubagem de circulação externa é DN15 ou DN20, não estrangular, o que aumentará a carga da bomba de circulação,
      Os tubos têm de ser isolados e adotar tubos de isolamento de borracha e plástico que possam suportar temperaturas elevadas.
      Opcional Quando a temperatura é inferior à temperatura normal, o sistema de refrigeração adopta o PID de refrigeração para ajustar a capacidade de refrigeração e não adopta as contramedidas de aquecimento, de modo a atingir o objetivo de poupança de energia

      Descrição do produto



      Temperatura de ensaio dos principais itens de ensaio da eletrónica do veículo:


         Condições de ensaio do CI para locomotivas: -40℃~125℃, vento soprando, exposição ao sol, alta vibração;
         Condições de teste de funcionamento do painel de instrumentos: -40℃~85℃;
        Condições de teste do controlador do motor: temperatura de teste operacional: 40 ℃ ~ 110 ℃;
      Posicionamento por satélite (GPS) Condições de teste: temperatura de teste de operação de alta temperatura: 85 ℃; temperatura de teste de operação de baixa temperatura: -40 ℃;
        Vibração composta: -40℃~80℃;
        É evidente que a melhor solução é que a casa de ensaios disponha de um equipamento de simulação de temperatura.

      Clique na mensagem online para obter informações sobre os detalhes do produto
      Envie-nos uma mensagem sobre a série KRY
      Envie-nos uma mensagem sobre a série KRY
      *
      *
      正在提交中....
      提交成功!
      提交失败!请稍后再试
      邮箱错误!
      电话错误!

      Também pode estar interessado nestes produtos

      carregando...

      已经是到最后一篇内容了!

      ]]>
      https://pt.lneya.com/cooling-heating-temperature-control-flow-system/kry-3.html/feed 0
      KRY 0℃~+100℃(1&6) https://pt.lneya.com/cooling-heating-temperature-control-flow-system/kry-6.html https://pt.lneya.com/cooling-heating-temperature-control-flow-system/kry-6.html#respond Wed, 17 May 2023 08:02:26 +0000 https://www.lneya.com/special-chiller/kry-6.html
      KRY 0℃~+100℃(1&6)
      KRY 0℃~+100℃(1&6)
      KRY 0℃~+100℃(1&6)
      KRY 0℃~+100℃(1&6)
      KRY 0℃~+100℃(1&6)

      KRY 0℃~100℃ 1&6S

      Refrigerador de temperatura normal para simulação de temperatura de ensaio de anticongelante para veículos
      • Potência de aquecimento15kW~38kW
      • Capacidade de arrefecimento18kW~60kW
      • Gama de potência38kW~82kW
      • Precisão da temperatura±0.5℃
      • Saída do caudal2~50 L/min
      • RefrigeranteR404A/R507C/R125/N40
      • Peso900KG~1950KG

      Descarregamento de dados do produto

      KRY 0℃~100℃ 1&6S (6 conjuntos de controlo de temperatura auxiliar, pressão e fluxo controlados separadamente)

      Modelo KRY-A25W/6S KRY-A38W/6S KRY-A60W/6S
      Temp. Gama 0℃~+100℃
      Precisão do controlo da temperatura ±0.5℃ ±0.5℃ ±0.5℃
      Feedback da temperatura Pt100 Pt100 Pt100
      Indicação da temperatura 0.01k 0.01k 0.01k
      Controlo de fluxo/Grupo 2~20 L/min 2~20 L/min 2~20 L/min
      Precisão do controlo do caudal/Grupo ±0.2L ±0.2L ±0.2L
      Número de grupos de saída de fluido 6 Grupos 6 Grupos 6 Grupos
      controlo da pressão/Grupo 0,2bar~2,5bar 0,2bar~2,5bar 0,2bar~2,5bar
      descrição da pressão do caudal O equipamento pode controlar o caudal e a pressão separadamente. É necessário controlar ao mesmo tempo utilizando soluções diferentes (a personalizar)
      Potência de aquecimento 15kW 25kW 38kW
      capacidade de arrefecimento 100℃ 25kW 38kW 60kW
      20℃ 25kW 38kW 60kW
      5℃ 18kW 27kW 42kW
      compressão Compressor de roda Emerson Valley
      expansão Válvula de expansão eletrónica
      distribuidor de óleo Emerson
      Filtro seco, Pressão Danfoss
      Evaporador Permutador de calor de placas
      Bomba de circulação A bomba centrífuga Nangfang pode ser selecionada com a bomba magnética de marca importada
      Frequência Delta
      Fluxo, sensor de pressão Medidor de caudal de marca alemã, pressão da johnson Controls
      entrada, ecrã Ecrã tátil a cores de 5 polegadas \ Controlador PLC
      Comunicação Protocolo Modbus RTU Interface RS485, barramento de comunicação CAN opcional, interface Ethernet Protocolo TCP/IP
      Proteção de segurança Com função de auto-diagnóstico; Proteção contra sobrecarga do frigorífico; Interruptor de alta pressão, relé de sobrecarga, proteção térmica
      dispositivo, proteção contra nível baixo de líquido, proteção contra temperaturas elevadas, proteção contra falhas do sensor e outras funções de segurança
      é um sistema totalmente fechado Todo o sistema é um sistema totalmente fechado, não haverá névoa de óleo a alta temperatura e a água no ar não será absorvida a baixa temperatura. O sistema não aumentará a pressão devido à alta temperatura em funcionamento, e o meio de condução térmica será automaticamente suplementado a baixa temperatura.
      refrigerante R404A/R507C/R125/N40 Estão disponíveis todos os quatro fluidos frigorigéneos
      Tamanho da ligação Existem seis grupos de entrada e saída,ZG3/4
      Água de arrefecimento a 20C° 6000L/H 9000L/H 15000L/H
      Condensador(W) Permutador de calor de tipo tubular Shenshi
      Potência 380V50HZ 38kW 55kW 82kW
      Dimensão cm 200*145*205 200*145*205 200*145*205
      Peso 900 kg 1200kg 1950kg
      Opcional 220V 60HZ trifásico 460V 60H trifásico
      Opcional Estender para -40~+135℃
      Opcional O tamanho da tubagem de circulação externa é DN15 ou DN20, não estrangular, o que aumentará a carga da bomba de circulação,
      Os tubos têm de ser isolados e adotar tubos de isolamento de borracha e plástico que possam suportar temperaturas elevadas.
      Opcional Quando a temperatura é inferior à temperatura normal, o sistema de refrigeração adopta o PID de refrigeração para ajustar a capacidade de refrigeração e não adopta as contramedidas de aquecimento, de modo a atingir o objetivo de poupança de energia

      Descrição do produto



      Princípio de funcionamento

      Simulação de temperatura para o teste de qualidade do veículo: teste da duração da bateria, banco de ensaio do injetor/motor de combustível, teste do airbag, banco de ensaio de componentes, etc. Pode simular as condições ambientais externas na câmara climática ou substituir o sistema interno, o que pode criar as condições de temperatura reais necessárias para o banco de ensaio.

      Temperatura de ensaio dos principais itens de ensaio da eletrónica do veículo:


         Condições de ensaio do CI para locomotivas: -40℃~125℃, vento soprando, exposição ao sol, alta vibração;
         Condições de teste de funcionamento do painel de instrumentos: -40℃~85℃;
        Condições de teste do controlador do motor: temperatura de teste operacional: 40 ℃ ~ 110 ℃;
      Posicionamento por satélite (GPS) Condições de teste: temperatura de teste de operação de alta temperatura: 85 ℃; temperatura de teste de operação de baixa temperatura: -40 ℃;
        Vibração composta: -40℃~80℃;
        É evidente que a melhor solução é que a casa de ensaios disponha de um equipamento de simulação de temperatura.

      Clique na mensagem online para obter informações sobre os detalhes do produto
      Pedir um orçamento e informações sobre o programa
      Pedir um orçamento e informações sobre o programa
      *
      *
      正在提交中....
      提交成功!
      提交失败!请稍后再试
      邮箱错误!
      电话错误!

      Também pode estar interessado nestes produtos

        carregando...

        已经是到最后一篇内容了!

        ]]>
        https://pt.lneya.com/cooling-heating-temperature-control-flow-system/kry-6.html/feed 0