Pesquisar toda a estação

KRY Multi-channel Series Battery Testing Thermal Control Solutions

Soluções de controlo térmico para testes de baterias da série KRY Multi-channel

APLICAÇÕES

Control temperature & flow system supports one to many, meaning that one refrigeration and heating temperature control flow host can control 2-6 different test benches or demand temperature control flow devices. Support two one to many modes, one is that temperature/flow/pressure can be independently controlled (T-series), and the other is that temperature is consistent across multiple groups, and flow/pressure is independently controlled (S-series).(LNEYA’s chiller supports both indoor and outdoor options.)

Modelo KRY-475/2T
KRY-475W/2T
KRY-4A15W/2T KRY-4A25W/2T KRY-4A38W/2T KRY-4A60W/2T
Gama de temperaturas -40℃~+100℃
Precisão do controle de temperatura ±0.3℃ ±0.3℃ ±0.3℃ ±0.3℃ ±0.3℃
Feedback da temperatura Pt100 Pt100 Pt100 Pt100 Pt100
Exibição de temperatura 0.01k 0.01k 0.01k 0.01k 0.01k
Precisão do controlo do caudal/Grupo 1~25 L/min 1~40 L/min 1~40 L/min 1~40 L/min 1~40 L/min
Precisão da vazão/grupo ±0,2 L/min ±0,2 L/min ±0,2 L/min ±0,2 L/min ±0,2 L/min
Número de grupos de saída de fluido 2 grupos 2 grupos 2 grupos 2 grupos 2 grupos
Controle de pressão/grupo 0,2bar~2,5bar 0,2bar~2,5bar 0,2bar~2,5bar 0,2bar~2,5bar 0,2bar~2,5bar
Descrição da pressão de fluxo A unidade pode controlar o fluxo individualmente ou separadamente. Necessidade de controlar diferentes soluções ao mesmo tempo (personalizado)
Capacidade de aquecimento 7.5kW*2 10kW*2 15kW*2 25kW*2 38kW*2
Capacidade de resfriamento 100℃ 7.5kW*2 15kW*2 25kW*2 38kW*2 60kW*2
20℃ 7.5kW*2 15kW*2 25kW*2 38kW*2 60kW*2
0℃ 7.5kW*2 15kW*2 25kW*2 38kW*2 60kW*2
-20℃ 4.5kW*2 8.5kW*2 14kW*2 22kW*2 35kW*2
-35℃ 1.8kW*2 4kW*2 6.5kW*2 10kW*2 15kW*2
Compressor Emerson Copeland
Tipo de acelerador Válvula de expansão eletrónica
Separador de óleo Emerson/GUANYA
Filtro seco Danfoss
Evaporador Permutador de calor de placas
Bomba de circulação Magnetic driven pump
Pressão de fluxo Electromagnetic flowmeter, pressure value 4~20mA
Ecrã de entrada Ecrã tátil a cores de 7 polegadas \ Controlador PLC
Comunicação Protocolo Modbus RTU Interface RS485, barramento de comunicação CAN opcional, interface Ethernet Protocolo TCP/IP
Proteção de segurança With self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection device, high temperature protection, sensor fault protection and other safety functions
Closed circulation  system The whole system is a fully closed system, there will be no oil mist at high temperature, the system in operation will
not because of high temperature pressure rise, low temperature automatically add heat conduction medium
refrigerante R404A/R507C/R125/N40All four refrigerants are available
Tamanho da conexão There are 2 groups of inlet and outlet, ZG3/4
Tipo resfriado a água Wat 20℃ 4000L/H
ZG1
8000L/H
DN32
12000L/H
DN40
20000L/H
DN50
30000L/H
DN65
Condensador(W) Condenser adopts plate heat exchanger, so please use chiller to provide cooling water or low hardness tap water
Dimensão(cm) 28kW 45kW 70kW 108kW 158kW
水冷尺寸cm 80*100*185 100*150*185 200*145*205 200*145*205 250*145*225
Peso 660KG 850 kg 1350kg 1800 kg 2600kg
Opcional 220V 60HZ Three phase 460V 60HZ Three phase
Opcional Estender para -40~+135℃
Opcional Automatic liquid recovery system
Material da caixa Chapas laminadas a frio (REL7035)

 

Modelo KRY-A25W/6S KRY-A38W/6S KRY-A60W/6S
Gama de temperaturas 0℃~+100℃
Precisão do controle de temperatura ±0.3℃ ±0.3℃ ±0.3℃
Feedback da temperatura Pt100 Pt100 Pt100
Exibição de temperatura 0.01k 0.01k 0.01k
Precisão do controlo do caudal/Grupo 2~25 L/min 2~25 L/min 2~25 L/min
Precisão da vazão/grupo ±0,2L/min
Número de grupos de saída de fluido 6 grupos 6 grupos 6 grupos
Controle de pressão/grupo 0,2bar~2,5bar 0,2bar~2,5bar 0,2bar~2,5bar
Descrição da pressão de fluxo A unidade pode controlar o fluxo individualmente ou separadamente. Necessidade de controlar diferentes soluções ao mesmo tempo (personalizado)
Capacidade de aquecimento 15kW 25kW 38kW
Capacidade de resfriamento 100℃ 25kW 38kW 60kW
20℃ 25kW 38kW 60kW
5℃ 18kW 27kW 42kW
Compressor Brand Copeland
Tipo de acelerador Válvula de expansão eletrónica
Separador de óleo Emerson/GUANYA
Filtro seco Danfoss
Evaporador Permutador de calor de placas
Bomba de circulação Centrifugal pump, optional magnetic drive pump
Pressão de fluxo Electromagnetic flowmeter, pressure value 4~20mA
Ecrã de entrada Ecrã tátil a cores de 7 polegadas \ Controlador PLC
Comunicação Protocolo Modbus RTU Interface RS485, barramento de comunicação CAN opcional, interface Ethernet Protocolo TCP/IP
Proteção de segurança With self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection device, high temperature protection, sensor fault protection and other safety functions
refrigerante R410A
Tamanho da conexão There are six groups of inlet and outlet, ZG3/4
Water-cooled type @ 20℃ 6000L/H
DN32
9000L/H
DN40
15000L/H
DN50
Condensador(W) Permutador de calor de tipo tubular Shenshi
Potência 380V50HZ 38kW 55kW 82kW
Dimensão(cm) 200*145*205 200*145*205 200*145*205
Peso 900 kg 1200kg 1950kg
Opcional O tamanho da tubagem de circulação externa é DN15 ou DN20, não estrangular, o que aumentará a carga da bomba de circulação,
need to be insulated, and adopt rubber and plastic insulation pipe which can afford high temp, liquid low level protection
Opcional 220V 60HZ three-phase 460V 60HZ three-phase
Opcional Higher precision control of temperature, flow rate, and pressure
Opcional Número de grupos de saída de fluido
Opcional Automatic antifreeze system
Opcional Automatic liquid recovery system
Material da caixa Chapas laminadas a frio (REL7035)

Modelo KRY-475/2T
KRY-475W/2T
KRY-4A15W/2T KRY-4A25W/2T KRY-4A38W/2T KRY-4A60W/2T
Gama de temperaturas -40℃~+100℃
Precisão do controle de temperatura ±0.3℃ ±0.3℃ ±0.3℃ ±0.3℃ ±0.3℃
Feedback da temperatura Pt100 Pt100 Pt100 Pt100 Pt100
Exibição de temperatura 0.01k 0.01k 0.01k 0.01k 0.01k
Precisão do controlo do caudal/Grupo 1~25 L/min 1~40 L/min 1~40 L/min 1~40 L/min 1~40 L/min
Precisão da vazão/grupo ±0,2 L/min ±0,2 L/min ±0,2 L/min ±0,2 L/min ±0,2 L/min
Número de grupos de saída de fluido 2 grupos 2 grupos 2 grupos 2 grupos 2 grupos
Controle de pressão/grupo 0,2bar~2,5bar 0,2bar~2,5bar 0,2bar~2,5bar 0,2bar~2,5bar 0,2bar~2,5bar
Descrição da pressão de fluxo A unidade pode controlar o fluxo individualmente ou separadamente. Necessidade de controlar diferentes soluções ao mesmo tempo (personalizado)
Capacidade de aquecimento 7.5kW*2 10kW*2 15kW*2 25kW*2 38kW*2
Capacidade de resfriamento 100℃ 7.5kW*2 15kW*2 25kW*2 38kW*2 60kW*2
20℃ 7.5kW*2 15kW*2 25kW*2 38kW*2 60kW*2
0℃ 7.5kW*2 15kW*2 25kW*2 38kW*2 60kW*2
-20℃ 4.5kW*2 8.5kW*2 14kW*2 22kW*2 35kW*2
-35℃ 1.8kW*2 4kW*2 6.5kW*2 10kW*2 15kW*2
Compressor Emerson Copeland
Tipo de acelerador Válvula de expansão eletrónica
Separador de óleo Emerson/GUANYA
Filtro seco Danfoss
Evaporador Permutador de calor de placas
Bomba de circulação Magnetic driven pump
Pressão de fluxo Electromagnetic flowmeter, pressure value 4~20mA
Ecrã de entrada Ecrã tátil a cores de 7 polegadas \ Controlador PLC
Comunicação Protocolo Modbus RTU Interface RS485, barramento de comunicação CAN opcional, interface Ethernet Protocolo TCP/IP
Proteção de segurança With self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection device, high temperature protection, sensor fault protection and other safety functions
Closed circulation  system The whole system is a fully closed system, there will be no oil mist at high temperature, the system in operation will
not because of high temperature pressure rise, low temperature automatically add heat conduction medium
refrigerante R404A/R507C/R125/N40All four refrigerants are available
Tamanho da conexão There are 2 groups of inlet and outlet, ZG3/4
Tipo resfriado a água Wat 20℃ 4000L/H
ZG1
8000L/H
DN32
12000L/H
DN40
20000L/H
DN50
30000L/H
DN65
Condensador(W) Condenser adopts plate heat exchanger, so please use chiller to provide cooling water or low hardness tap water
Dimensão(cm) 28kW 45kW 70kW 108kW 158kW
水冷尺寸cm 80*100*185 100*150*185 200*145*205 200*145*205 250*145*225
Peso 660KG 850 kg 1350kg 1800 kg 2600kg
Opcional 220V 60HZ Three phase 460V 60HZ Three phase
Opcional Estender para -40~+135℃
Opcional Automatic liquid recovery system
Material da caixa Chapas laminadas a frio (REL7035)

Modelo KRY-475/2T
KRY-475W/2T
KRY-4A15W/2T KRY-4A25W/2T KRY-4A38W/2T KRY-4A60W/2T
Gama de temperaturas -40℃~+100℃
Precisão do controle de temperatura ±0.3℃ ±0.3℃ ±0.3℃ ±0.3℃ ±0.3℃
Feedback da temperatura Pt100 Pt100 Pt100 Pt100 Pt100
Exibição de temperatura 0.01k 0.01k 0.01k 0.01k 0.01k
Precisão do controlo do caudal/Grupo 1~25 L/min 1~40 L/min 1~40 L/min 1~40 L/min 1~40 L/min
Precisão da vazão/grupo ±0,2 L/min ±0,2 L/min ±0,2 L/min ±0,2 L/min ±0,2 L/min
Número de grupos de saída de fluido 2 grupos 2 grupos 2 grupos 2 grupos 2 grupos
Controle de pressão/grupo 0,2bar~2,5bar 0,2bar~2,5bar 0,2bar~2,5bar 0,2bar~2,5bar 0,2bar~2,5bar
Descrição da pressão de fluxo A unidade pode controlar o fluxo individualmente ou separadamente. Necessidade de controlar diferentes soluções ao mesmo tempo (personalizado)
Capacidade de aquecimento 7.5kW*2 10kW*2 15kW*2 25kW*2 38kW*2
Capacidade de resfriamento 100℃ 7.5kW*2 15kW*2 25kW*2 38kW*2 60kW*2
20℃ 7.5kW*2 15kW*2 25kW*2 38kW*2 60kW*2
0℃ 7.5kW*2 15kW*2 25kW*2 38kW*2 60kW*2
-20℃ 4.5kW*2 8.5kW*2 14kW*2 22kW*2 35kW*2
-35℃ 1.8kW*2 4kW*2 6.5kW*2 10kW*2 15kW*2
Compressor Emerson Copeland
Tipo de acelerador Válvula de expansão eletrónica
Separador de óleo Emerson/GUANYA
Filtro seco Danfoss
Evaporador Permutador de calor de placas
Bomba de circulação Magnetic driven pump
Pressão de fluxo Electromagnetic flowmeter, pressure value 4~20mA
Ecrã de entrada Ecrã tátil a cores de 7 polegadas \ Controlador PLC
Comunicação Protocolo Modbus RTU Interface RS485, barramento de comunicação CAN opcional, interface Ethernet Protocolo TCP/IP
Proteção de segurança With self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection device, high temperature protection, sensor fault protection and other safety functions
Closed circulation  system The whole system is a fully closed system, there will be no oil mist at high temperature, the system in operation will
not because of high temperature pressure rise, low temperature automatically add heat conduction medium
refrigerante R404A/R507C/R125/N40All four refrigerants are available
Tamanho da conexão There are 2 groups of inlet and outlet, ZG3/4
Tipo resfriado a água Wat 20℃ 4000L/H
ZG1
8000L/H
DN32
12000L/H
DN40
20000L/H
DN50
30000L/H
DN65
Condensador(W) Condenser adopts plate heat exchanger, so please use chiller to provide cooling water or low hardness tap water
Dimensão(cm) 28kW 45kW 70kW 108kW 158kW
水冷尺寸cm 80*100*185 100*150*185 200*145*205 200*145*205 250*145*225
Peso 660KG 850 kg 1350kg 1800 kg 2600kg
Opcional 220V 60HZ Three phase 460V 60HZ Three phase
Opcional Estender para -40~+135℃
Opcional Automatic liquid recovery system
Material da caixa Chapas laminadas a frio (REL7035)

Controlo da temperatura

Controlo da pressão

Controlo do fluxo

Controlo da temperatura

Controlo da pressão

Controlo do fluxo

Controlo consistente da temperatura

Controlo da pressão

Controlo do fluxo

APLICAÇÕES

Solução de controlo da temperatura de verificação de componentes de veículos de energia nova

As aplicações são múltiplas. As áreas de aplicação típicas incluem a investigação, o ensaio e o controlo de qualidade de baterias e motores de energia nova; também pode ser aplicado à simulação ambiental, ao ensaio de materiais e ao ensaio de cargas e tensões relacionadas com a temperatura de materiais, transmissões, rolamentos e peças de motores.


Desde a nossa fundação em 2006, já servimos mais de 30.000 clientes e detemos várias patentes que demonstram a nossa inovação e fiabilidade. Os nossos chillers são selecionados para mais de 100 universidades projectos de laboratório em todo o mundo e exportados para mais de 20 países. Asseguramos a mais alta qualidade através de um rigoroso 3 passos processo de controlo de qualidade: inspeção visual, testes de desempenho e testes de segurança eléctrica. O nosso compromisso com a excelência é ainda apoiado pela nossa Cliente 24/7 compromisso de suporte. Além disso, temos agentes nos Estados Unidos, Canadá, Austrália, Rússia e Coreia do Sul, o que nos torna um parceiro global e de confiança para as suas necessidades de chillers. Escolha a lneya para obter qualidade e suporte para seu projeto.
18+

Anos de experiência

30000+

Clientes satisfeitos

25000

m² Área de produção

80+

Tecnologias patenteadas

*
*
Submeter....
Enviado com sucesso!
A submissão falhou! Tente novamente mais tarde
Erro de correio eletrónico!
Erro telefónico!
*
*
Submeter....
Enviado com sucesso!
A submissão falhou! Tente novamente mais tarde
Erro de correio eletrónico!
Erro telefónico!