Pesquisar toda a estação

SUNDIZ Variable Frequency Series Cooling Heating Systems

SUNDIZ Variable Frequency Series Cooling Heating Systems

APLICAÇÕES

Compared with SUNDI refrigeration system, the circulation system adopts variable frequency control, which saves more than 20% energy, reduces noise by more than 5 decibels, and has a small starting current compared to old products.

By increasing the frequency, the refrigeration power is increased and the cooling rate is improved by frequency conversion control of the circulation pump.

SUNDIZ -45℃~250℃

 

 Modelo SUNDIZ4-3
SUNDIZ4-3W
SUNDIZ4-5
SUNDIZ4-5W
SUNDIZ4-10
SUNDIZ4-10W
SUNDIZ4-15W SUNDIZ4-20W SUNDIZ4-30W
Gama de temperaturas -45℃~250℃
Potência de aquecimento 5,5 kW 7,5 kW 15kW 25kW 38kW 60kW
Cooling  capacity  kW 250℃ 5,5 kW 7,5 kW 15kW 25 kW 38kW 60kW
20℃ 5,5 kW 7,5 kW 15 kW 25kW 38kW 60kW
-15℃ 2,3kW 3.6kW 7.5 kW 11kW 15kW 33kW
-35℃ 0,9kW 1.5kW 3.3 kW 5kW 6,5 kW 10kW
Medium temp control accuracy ±0.1℃ ±0.1℃ ±0.1℃ ±0.1℃ ±0.1℃ ±0.1℃
Process temp control accuracy ±0.3℃ ±0.3℃ ±0.3℃ ±0.3℃ ±0.3℃ ±0.3℃
Pump flow rate  pressure max 50L/min 50L/min 100L/min 150L/min 250L/min 400L/min
2bar 2bar 2bar 2,5 bar 2,5 bar 2,5 bar
Refrigerante R-404A / R507C Optional R448
Tamanho da interface G3/4 G3/4 G1 DN32 PN10 DN40 PN10 DN50 PN10

 

SUNDIZ -80℃~250℃

 

 Modelo SUNDIZ8-3W SUNDIZ8-4W SUNDIZ8-6W SUNDIZ8-10W SUNDIZ8-15W
Gama de temperaturas  -80℃~250℃
Potência de aquecimento 3,5 kW 5,5 kW 7,5 kW 10kW 15kW
Cooling  capacity  kW 250℃ 3,5 kW 5,5 kW 7,5 kW 15 kW 20kW
20℃ 3,5 kW 5,5 kW 7.5 kW 15kW 20kW
-60℃ 1.3kW 1,8kW 3 kW 5,5 kW 8kW
-75℃ 0.4kW 0,6kW 1 kW 1,8kW 2.7kW
Medium temp control accuracy ±0.1℃ ±0.1℃ ±0.1℃ ±0.1℃ ±0.1℃
Process temp control accuracy ±0.3℃ ±0.3℃ ±0.3℃ ±0.3℃ ±0.3℃
Pump flow rate  pressure max 35L/min 50L/min 100L/min 150L/min 250L/min
2bar 2bar 2bar 2,5 bar 2,5 bar
Refrigerante R-404A / R508B

 

Common Configuration

 

Indicação da pressão do sistema The pressure of the refrigeration system and circulation system is detected by pressure sensors and displayed on the touch screen
Controlador Siemens S7-1200 PLC, fuzzy PID control algorithm, equipped with process dynamic control algorithm
Controlo da temperatura Thermal medium outlet temperature control mode, external temperature sensor: (PT100 or 4-20mA or communication
given) control mode (process dynamic control algorithm)
Programável 25 programs, each program can edit 85 steps
Communication Protocol Ethernet interface TCP/IP protocol, RS485 interface, MODBUS protocol
Internal temp feedback Equipment thermal conductivity medium outlet temperature, medium inlet temperature, refrigeration system condensation
temperature, compressor suction temperature, cooling water temperature (for water-cooled equipment)
External temp feedback Pt100 or 4-20mA or communication given
During cascade control
Temp difference control
function
The temp difference between the outlet temp of the thermal oil and the external temp sensor can be set and controlled
The temp difference between the inlet and outlet of the equipment can be set and controlled to ensure system safety
Closed circulation
sistema
The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature,
pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
Aquecimento Refere-se à potência máxima de aquecimento do sistema (de acordo com cada modelo)
O aquecedor tem uma proteção tripla e um limitador de temperatura independente para garantir a segurança do sistema de aquecimento;
Using a voltage regulator to control the heating output and reduce the output current of the heater during process temperature control
External circulation Flow pressure Brand magnetic drive variable frequency pump
Compressor Emerson, Mitsubishi and other variable frequency compressors
Conversor de frequência Famous brands such as ABB
Evaporador 316L Plate Heat Exchanger
Acessórios de refrigeração Danfoss/Emerson accessories (dry filters, oil separators, high and low pressure protectors, expansion valves)
Painel de controlo Ecrã tátil a cores de 7 polegadas personalizado LNEYA, visualização da curva de temperatura\EXCEL exportação de dados
Proteção de segurança Multiple self-diagnosis function; freezer overload protection; high/low pressure switch; overload relay, thermal protection device etc
Water-cooled condenser Permutador de calor de placas
Material da casca Cold rolled sheet (standard color 7035)
Potência 380V 50HZ / 460V 60HZ

A tecnologia de resfriamento de temperatura ultra-alta pode resfriar diretamente a partir de uma alta temperatura de 300 ℃ [porque apenas o meio de transferência de calor na câmara de expansão entra em contato com o oxigênio no ar (e a temperatura do tanque de expansão está entre a temperatura normal e 60 ℃), o que pode reduzir o risco de o meio de transferência de calor ser oxidado e absorver água no ar. Em alta temperatura, nenhum meio condutor de calor evapora, e o controle contínuo de temperatura de - 80 ℃ ~ 190 ℃, - 70 ℃ ~ 220 ℃, - 88 ℃ ~ 170 ℃, - 55 ℃ ~ 250 ℃ e - 30 ℃ ~ 300 ℃ pode ser realizado sem pressurização.

1. Apresenta todos os tipos de temperaturas de controlo do processo.
2. Mostra o nível de líquido do fluido condutor de calor no vaso de expansão.
3. Mostra a indicação do funcionamento do sistema de refrigeração.
4. Mostra a indicação de funcionamento do aquecedor.
5. Mostra a indicação de funcionamento da bomba de circulação.
6. Apresenta o controlo da temperatura (padrão de controlo da temperatura dos materiais, controlo da temperatura média condutora de calor).
7. O controlo do limite superior e inferior da temperatura pode ser definido.
8. A diferença de temperatura entre a camisa e o material do reator pode ser definida.
9. Mostra o alarme para adicionar o líquido quando este estiver vazio.
10. O compressor de refrigeração pode ser regulado para funcionar manual ou automaticamente.

APLICAÇÕES

Novos materiais | Controlo da temperatura de produção de gases especiais

API | solução de controlo de temperatura de produção intermédia

Solução de controlo da temperatura da concentração de destilação

Saiba mais

Saiba mais


Since our founding in 2006, we have served over 30,000 customers and hold several patents that demonstrate our innovation and reliability. Our chillers are selected for over 100 university laboratory projects worldwide and exported to over 20 countries. We ensure the highest quality through a rigorous 3-step quality control process: visual inspection, performance testing, and electrical safety testing. Our commitment to excellence is further backed by our 24/7 customer support commitment. In addition, we have agents in the United States, Canada, Australia, Russia, and South Korea, making us a global, trusted partner for your chiller needs. Choose lneya for quality and support for your project.
18+

Years of experience

30000+

Satisfied Customers

25000

m² Production Area

80+

Patented Technologies

*
*