
SUNDIZ Variable Frequency Series Cooling Heating Systems
APLICAÇÕES
Compared with SUNDI refrigeration system, the circulation system adopts variable frequency control, which saves more than 20% energy, reduces noise by more than 5 decibels, and has a small starting current compared to old products.
By increasing the frequency, the refrigeration power is increased and the cooling rate is improved by frequency conversion control of the circulation pump.
Caraterísticas do produto
Parâmetros do produto
SUNDIZ -45℃~250℃
| Modelo | SUNDIZ4-3 SUNDIZ4-3W |
SUNDIZ4-5 SUNDIZ4-5W |
SUNDIZ4-10 SUNDIZ4-10W |
SUNDIZ4-15W | SUNDIZ4-20W | SUNDIZ4-30W | |
| Faixa de temperatura | -45℃~250℃ | ||||||
| Potência de aquecimento | 5,5 kW | 7,5 kW | 15kW | 25kW | 38kW | 60kW | |
| Capacidade de refrigeração kW | 250℃ | 5,5 kW | 7,5 kW | 15kW | 25 kW | 38kW | 60kW |
| 20℃ | 5,5 kW | 7,5 kW | 15 kW | 25kW | 38kW | 60kW | |
| -15℃ | 2,3kW | 3.6kW | 7.5 kW | 11kW | 15kW | 33kW | |
| -35℃ | 0,9kW | 1.5kW | 3.3 kW | 5kW | 6,5 kW | 10kW | |
| Precisão do controle de temperatura média | ±0.1℃ | ±0.1℃ | ±0.1℃ | ±0.1℃ | ±0.1℃ | ±0.1℃ | |
| Precisão do controle de temperatura do processo | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | |
| Vazão da bomba pressão máx | 50L/min | 50L/min | 100L/min | 150L/min | 250L/min | 400L/min | |
| 2bar | 2bar | 2bar | 2,5 bar | 2,5 bar | 2,5 bar | ||
| refrigerante | R-404A / R507C Optional R448A | ||||||
| Tamanho da interface | G3/4 | G3/4 | G1 | DN32 PN10 | DN40 PN10 | DN50 PN10 | |
SUNDIZ -80℃~250℃
| Modelo | SUNDIZ8-3W | SUNDIZ8-4W | SUNDIZ8-6W | SUNDIZ8-10W | SUNDIZ8-15W | |
| Faixa de temperatura | -80℃~250℃ | |||||
| Potência de aquecimento | 3,5 kW | 5,5 kW | 7,5 kW | 10kW | 15kW | |
| Capacidade de refrigeração kW | 250℃ | 3,5 kW | 5,5 kW | 7,5 kW | 15 kW | 20kW |
| 20℃ | 3,5 kW | 5,5 kW | 7.5 kW | 15kW | 20kW | |
| -60℃ | 1,3kW | 1,8kW | 3 kW | 5,5 kW | 8kW | |
| -75℃ | 0,4kW | 0,6kW | 1 kW | 1,8kW | 2.7kW | |
| Precisão do controle de temperatura média | ±0.1℃ | ±0.1℃ | ±0.1℃ | ±0.1℃ | ±0.1℃ | |
| Precisão do controle de temperatura do processo | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | |
| Vazão da bomba pressão máx | 35L/min | 50L/min | 100L/min | 150L/min | 250L/min | |
| 2bar | 2bar | 2bar | 2,5 bar | 2,5 bar | ||
| refrigerante | R-404A / R508B | |||||
Common Configuration
| Indicação da pressão do sistema | The pressure of the refrigeration system and circulation system is detected by pressure sensors and displayed on the touch screen | ||||
| Controlador | Siemens S7-1200 PLC, fuzzy PID control algorithm, equipped with process dynamic control algorithm | ||||
| Controlo da temperatura | Thermal medium outlet temperature control mode, external temperature sensor: (PT100 or 4-20mA or communication given) control mode (process dynamic control algorithm) |
||||
| Programável | 25 programs, each program can edit 85 steps | ||||
| Communication Protocol | Ethernet interface TCP/IP protocol, RS485 interface, MODBUS protocol | ||||
| Internal temp feedback | Equipment thermal conductivity medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, compressor suction temperature, cooling water temperature (for water-cooled equipment) |
||||
| External temp feedback | Pt100 or 4-20mA or communication given | ||||
| During cascade control Temp difference control function |
The temp difference between the outlet temp of the thermal oil and the external temp sensor can be set and controlled The temp difference between the inlet and outlet of the equipment can be set and controlled to ensure system safety |
||||
| Closed circulation sistema |
The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature. |
||||
| Aquecimento | Refere-se à potência máxima de aquecimento do sistema (de acordo com cada modelo) O aquecedor tem uma proteção tripla e um limitador de temperatura independente para garantir a segurança do sistema de aquecimento; Using a voltage regulator to control the heating output and reduce the output current of the heater during process temperature control |
||||
| External circulation Flow pressure | Brand magnetic drive variable frequency pump | ||||
| Compressor | Emerson, Mitsubishi and other variable frequency compressors | ||||
| Conversor de frequência | Famous brands such as ABB | ||||
| Evaporador | 316L Plate Heat Exchanger | ||||
| Acessórios de refrigeração | Danfoss/Emerson accessories (dry filters, oil separators, high and low pressure protectors, expansion valves) | ||||
| Painel de controlo | Ecrã tátil a cores de 7 polegadas personalizado LNEYA, visualização da curva de temperatura\EXCEL exportação de dados | ||||
| Proteção de segurança | Multiple self-diagnosis function; freezer overload protection; high/low pressure switch; overload relay, thermal protection device etc | ||||
| Condensador arrefecido a água | Permutador de calor de placas | ||||
| Material da casca | Cold rolled sheet (standard color 7035) | ||||
| Potência | 380V 50HZ / 460V 60HZ | ||||
PRINCÍPIO DE FUNCIONAMENTO

A tecnologia de resfriamento de temperatura ultra-alta pode resfriar diretamente a partir de uma alta temperatura de 300 ℃ [porque apenas o meio de transferência de calor na câmara de expansão entra em contato com o oxigênio no ar (e a temperatura do tanque de expansão está entre a temperatura normal e 60 ℃), o que pode reduzir o risco de o meio de transferência de calor ser oxidado e absorver água no ar. Em alta temperatura, nenhum meio condutor de calor evapora, e o controle contínuo de temperatura de - 80 ℃ ~ 190 ℃, - 70 ℃ ~ 220 ℃, - 88 ℃ ~ 170 ℃, - 55 ℃ ~ 250 ℃ e - 30 ℃ ~ 300 ℃ pode ser realizado sem pressurização.
Controlo do ecrã a cores

1. Apresenta todos os tipos de temperaturas de controlo do processo.
2. Mostra o nível de líquido do fluido condutor de calor no vaso de expansão.
3. Mostra a indicação do funcionamento do sistema de refrigeração.
4. Mostra a indicação de funcionamento do aquecedor.
5. Mostra a indicação de funcionamento da bomba de circulação.
6. Apresenta o controlo da temperatura (padrão de controlo da temperatura dos materiais, controlo da temperatura média condutora de calor).
7. O controlo do limite superior e inferior da temperatura pode ser definido.
8. A diferença de temperatura entre a camisa e o material do reator pode ser definida.
9. Mostra o alarme para adicionar o líquido quando este estiver vazio.
10. O compressor de refrigeração pode ser regulado para funcionar manual ou automaticamente.
Customized solutions to meet your temperature process needs
CUSTOM CHILLER SIZES
Quer se trate de refrigeradores portáteis, compactos, grandes ou pequenos, podemos concebê-los à medida das suas necessidades. Independentemente do número de toneladas de refrigerador de que necessita, podemos criar a melhor solução.
CUSTOM CHILLER TYPES
Fornecemos chillers de vários tipos de refrigeração, incluindo, entre outros, chillers arrefecidos a ar, arrefecidos a água e de condensação evaporativa. Independentemente do tipo de compressor de refrigeração, podemos projectá-lo de acordo com os seus requisitos.
CUSTOM TEMPERATURE RANGES
Podemos criar uma solução personalizada para temperaturas de -150 ℃ a +350 ℃. Faixas de temperatura personalizadas para indústrias específicas.
CUSTOM CHILLER VOLTAGE
Personalize a tensão e a fase do chiller de acordo com as suas necessidades. Opcional 110V/60HZ, 220V/60HZ, 380V/50HZ, 220V/50HZ, 400V/50HZ, 460V/60HZ, 440V~480V/60HZ, etc.
Porquê escolher a lneya como seu fornecedor de controlo de temperatura?
Anos de experiência
Clientes satisfeitos
m² Área de produção
Tecnologias patenteadas
Visitar a fábrica da LNEYA
contactar-nos
Envie-nos sua solicitação e entraremos em contato com você em até 24 horas
LNEYA Refrigeradores industriais Fabricante Fornecedor


























