
SUNDI series Chiller and Heater Combo Units
APLICAÇÕES
Dynamic constant temperature control of cold and hot sources of high-pressure reactors;
Dynamic constant temperature control of cold and hot sources of double-layer glass reactors;
Dynamic constant temperature control of cold and hot sources of double-layer reactors;
Constant temperature control of cold and hot sources of microchannel reactors;
Small constant temperature control systems, distillation system temperature control;
Low-temperature and high-temperature aging tests of materials;
Constant temperature control of combined chemical cold and hot sources;
Cooling and heating of semiconductor equipment;
Constant temperature control of refrigeration and heating of vacuum chambers.
Caraterísticas do produto
Parâmetros do produto
Modelo | SUNDI-320 SUNDI-320W | |
Gama de temperaturas | -30℃~180℃ | |
Medium temp accuracy | ±0.5℃ | |
Material temp accuracy |
±1℃ |
|
Potência de aquecimento | 2kW | |
Arrefecimento capacidade |
180℃ | 1.5kW |
50℃ | 1.5kW | |
0℃ | 1.5kW | |
-5℃ | 0,7kW | |
-15℃ | 0.4kW | |
Flow、pressure | max10L/min 0,8 bar |
|
Refrigerante | R-404A/R507C | |
Tamanho da ligação | ZG1/2 | |
Dimensão cm | 35*56*75 | |
Peso kg | 55 kg | |
Potência | AC 220V 50HZ 3.2kW(max) |
Modelo | SUNDI-135 SUNDI-135W |
SUNDI-155 SUNDI-155W |
SUNDI-175 SUNDI-175W |
SUNDI-1A10 SUNDI-1A10W |
SUNDI-1A15 SUNDI-1A15W |
|
Gama de temperaturas | -10℃~+150℃ | |||||
Modo de controlo | Feedback PID + O nosso cálculo de controlo dinâmico especial, controlador PLC | |||||
Controlo da temperatura | Controlo da temperatura do processo e modelo de controlo da temperatura da camisa | |||||
Temp difference | Definir ou controlar a diferença de temperatura entre o óleo de revestimento e o processo da matéria-prima | |||||
Editor de programas | 20 programs, each program can edit 40 steps | |||||
Communication Protoco | Protocolo MODBUS RTU, interface RS485 | |||||
Material temp feedback | PT100 | |||||
Feedback da temperatura | The temp of 3 points: the inlet and outlet of equipment,reactor material temperature(external temp. sensor) | |||||
Medium temp accuracy | ±0.5℃ | |||||
Material temp accuracy | ±1℃ | |||||
Potência de aquecimento | 3.5 | 5.5 | 7.5 | 10 | 15 | |
Arrefecimento capacidade |
150℃ | 3.5 | 5.5 | 7.5 | 10 | 15 |
20℃ | 3.5 | 5.5 | 7.5 | 10 | 15 | |
-5℃ | 2.1 | 3.3 | 4.2 | 6 | 9 | |
Flow、pressure max L/min bar |
35 | 35 | 50 | 50 | 75 | |
1 | 1 | 1.2 | 1.2 | 1.2 | ||
Compressor | Highly / Panasonic / Emerson copeland / scroll compressor | |||||
Válvula de expansão | Válvula de expansão eletrónica | |||||
Evaporador | Permutador de calor de placas | |||||
Painel de operações | Ecrã tátil de 7 polegadas , mostrar curva de temperatura \ saída de dados EXCEL | |||||
Proteção de segurança | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, high temperature protection and temperature fault protection. |
|||||
Sistema de circulação fechado | Todo o sistema é de circulação totalmente fechada, não há névoa de óleo a alta temperatura e não há vapor de água a baixa temperatura, a pressão não sobe quando o sistema está a funcionar. O sistema fornecerá óleo automaticamente a baixa temperatura. | |||||
Refrigerante | R-404A/R507C | |||||
Tamanho da ligação | ZG3/4 | ZG3/4 | ZG1 | ZG1 | ZG1 | |
Água de arrefecimento @20℃ |
1300L/H 1,5bar~4bar ZG1/2 |
1800L/H 1,5bar~4bar ZG3/4 |
1800L/H 1,5bar~4bar ZG3/4 |
2400L/H 1,5bar~4bar ZG3/4 |
3600L/H 1,5bar~4bar ZG1 |
|
Dimensão cm | 45*70*160 | 45*70*160 | 55*70*175 | 55*70*175 | 70*85*185 | |
Peso kg | 165 | 185 | 235 | 280 | 300 | |
Potência 380V 50HZ | 6.7kW | 9,5 kW | 12kW | 15.5kW | 23kW | |
Case materia | Cold rolled steel powder coating (standard color 7035) | |||||
Opcional | Optional Ethernet interface and computer operation software configuration | |||||
Opcional | Outside touch screen display controller, the communication line distance is 10 meter |
|||||
OptionalPower | 110V 50HZ single-phase, 110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ 3-phase, 440V~460V 60HZ 3-phase |
Modelo | SUNDI-235 SUNDI-235W |
SUNDI-255 SUNDI-255W |
SUNDI-275 SUNDI-275W |
SUNDI-2A10 SUNDI-2A10W |
SUNDI-2A15 SUNDI-2A15W |
SUNDI-2A25 SUNDI-2A25W |
SUNDI-2A38W | SUNDI-2A60W | SUNDI-2A95W | SUNDI-2A130W | SUNDI-2A200W | |
Gama de temperaturas | -25℃~+200℃(can be -25℃~+300℃) | |||||||||||
Modo de controlo | Feedback PID + O nosso cálculo de controlo dinâmico especial, controlador PLC | |||||||||||
Controlo da temperatura | Controlo da temperatura do processo e modelo de controlo da temperatura da camisa | |||||||||||
Temp difference | Definir ou controlar a diferença de temperatura entre o óleo de revestimento e o processo da matéria-prima | |||||||||||
Editor de programas | 20 programs, each program can edit 40 steps | |||||||||||
Communication Protoco | Protocolo MODBUS RTU, interface RS485 | |||||||||||
Material temp feedback | PT100 | |||||||||||
Feedback da temperatura | The temp of 3 points: the inlet and outlet of equipment,reactor material temperature(external temp. sensor) | |||||||||||
Medium temp accuracy | ±0.5℃ | |||||||||||
Material temp accuracy | ±1℃ | |||||||||||
Potência de aquecimento | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
Arrefecimento capacidade |
200℃ | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 |
100℃ | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
50℃ | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
20℃ | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
-5℃ | 3 | 4.5 | 6.3 | 8 | 11 | 19 | 30 | 46 | 70 | 80 | 125 | |
-15℃ | 1.8 | 2.8 | 3.8 | 4.6 | 7 | 12 | 16 | 22 | 32 | 43 | 65 | |
Flow、pressure max L/min bar |
35 | 35 | 50 | 60 | 110 | 150 | 200 | 250 | 400 | 400 | 600 | |
1.2 | 1.2 | 1.2 | 1.2 | 1.5 | 1.5 | 1.5 | 2.5 | 2.5 | 2.5 | 2.5 | ||
Compressor | Tecumseh Emerson copeland / Carlyle | |||||||||||
Válvula de expansão | Válvula de expansão eletrónica | |||||||||||
Evaporador | Permutador de calor de placas | |||||||||||
Painel de operações | Ecrã tátil de 7 polegadas , mostrar curva de temperatura \ saída de dados EXCEL | |||||||||||
Proteção de segurança | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, high temperature protection and temperature fault protection. |
|||||||||||
Sistema de circulação fechado | Todo o sistema é de circulação totalmente fechada, não há névoa de óleo a alta temperatura e não há vapor de água a baixa temperatura, a pressão não sobe quando o sistema está a funcionar. O sistema fornecerá óleo automaticamente a baixa temperatura. | |||||||||||
Refrigerante | R-404A/R507C | |||||||||||
Tamanho da ligação | ZG3/4 | ZG3/4 | ZG1 | ZG1 | ZG1 | DN32 | DN40 | DN50 | DN65 | DN65 | DN80 | |
Água de arrefecimento @20℃ |
1500L/H 1,5bar~4bar ZG1/2 |
1800L/H 1,5bar~4bar ZG3/4 |
3000L/H 1,5bar~4bar ZG3/4 |
4200L/H 1,5bar~4bar ZG3/4 |
5400L/H 1,5bar~4bar DN32 |
10m³/H 1,5bar~4bar DN40 |
10m³/H 1,5bar~4bar DN40 |
14m³/H 1,5bar~4bar DN50 |
19m³/H 1,5bar~4bar DN65 |
24m³/H 1,5bar~4bar DN65 |
36m³/H 1,5bar~4bar DN80 |
|
Dimensão cm | 45*70*160 | 45*70*160 | 55*70*175 | 65*85*185 | 70*85*185 | 80*120*185 | 150*100*185 | 200*145*205 | 200*145*205 | 250*145*225 | 300*160*225 | |
Peso kg | 165 | 185 | 230 | 280 | 300 | 550 | 750 | 1000 | 1250 | 1580 | 2150 | |
Potência 380V 50HZ | 6.7kW | 9,5 kW | 15kW | 16kW | 27kW | 48kW | 55kW | 81kW | 126kW | 175kW | 260kW | |
Case materia | Cold rolled steel powder coating (standard color 7035) | |||||||||||
Opcional | Optional Ethernet interface and computer operation software configuration | |||||||||||
Opcional | Outside touch screen display controller, the communication line distance is 10 meter |
|||||||||||
OptionalPower | 110V 50HZ single-phase, 110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ 3-phase, 440V~460V 60HZ 3-phase | |||||||||||
Opcional | SUNDI series can provide optional medium temperature control accuracy of ± 0.1 ℃ and material temperature control accuracy of ± 0.1 ℃ within a heating power of 25kW |
Modelo | SUNDI-525 SUNDI-525W |
SUNDI-535 SUNDI-535W |
SUNDI-555 SUNDI-555W |
SUNDI-575 SUNDI-575W |
SUNDI-5A10 SUNDI-5A10W |
SUNDI-5A15 SUNDI-5A15W |
SUNDI-4A25 SUNDI-4A25W |
SUNDI-4A38W | SUNDI-4A60W | SUNDI-4A95W | SUNDI-4A130W | SUNDI-4A200W | |
Gama de temperaturas | -45℃~+250℃ | ||||||||||||
Modo de controlo | Feedback PID + O nosso cálculo de controlo dinâmico especial, controlador PLC | ||||||||||||
Controlo da temperatura | Controlo da temperatura do processo e modelo de controlo da temperatura da camisa | ||||||||||||
Temp difference | Definir ou controlar a diferença de temperatura entre o óleo de revestimento e o processo da matéria-prima | ||||||||||||
Editor de programas | 20 programs, each program can edit 40 steps | ||||||||||||
Communication Protoco | Protocolo MODBUS RTU, interface RS485 | ||||||||||||
Material temp feedback | PT100 | ||||||||||||
Feedback da temperatura | The temp of 3 points: the inlet and outlet of equipment,reactor material temperature(external temp. sensor) | ||||||||||||
Medium temp accuracy | ±0.5℃ | ||||||||||||
Material temp accuracy | ±1℃ | ||||||||||||
Potência de aquecimento | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
Capacidade de arrefecimento | 250℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 |
100℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
20℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
0℃ | 1.8 | 3 | 5 | 7 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
-20℃ | 0.85 | 1.5 | 2.3 | 3.6 | 5 | 7.6 | 11 | 20 | 29 | 42 | 54 | 98 | |
-35℃ | 0.25 | 0.45 | 0.9 | 1.5 | 2 | 3.8 | 4.7 | 9 | 12 | 18 | 24 | 43 | |
Flow、pressure max L/min bar | 20 | 35 | 35 | 50 | 60 | 110 | 150 | 200 | 250 | 400 | 400 | 600 | |
1.2 | 1.2 | 1.2 | 1.2 | 1.5 | 1.5 | 1.5 | 1.5 | 2.5 | 2.5 | 2.5 | 2.5 | ||
Bomba de circulação | Bomba de acionamento magnético | ||||||||||||
Compressor | Tecumseh/Emerson copeland/Carlyle | ||||||||||||
Válvula de expansão | Válvula de expansão eletrónica | ||||||||||||
Evaporador | Permutador de calor de placas | ||||||||||||
Painel de operações | Ecrã tátil de 7 polegadas , mostrar curva de temperatura \ saída de dados EXCEL | ||||||||||||
Proteção de segurança | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, high temperature protection and temperature fault protection. |
||||||||||||
Sistema de circulação fechado | Todo o sistema é de circulação totalmente fechada, não há névoa de óleo a alta temperatura e não há vapor de água a baixa temperatura, a pressão não sobe quando o sistema está a funcionar. O sistema fornecerá óleo automaticamente a baixa temperatura. | ||||||||||||
Refrigerante | R-404A/R507C | ||||||||||||
Tamanho da ligação | ZG1/2 | ZG3/4 | ZG3/4 | ZG3/4 | ZG1 | ZG1 | DN32 | DN50 | DN50 | DN65 | DN65 | DN65 | |
Água de arrefecimento @20℃ |
900L/H 1,5bar~4bar ZG1/2 |
1400L/H 1,5bar~4bar ZG1/2 |
1800L/H 1,5bar~4bar ZG3/4 |
2400L/H 1,5bar~4bar ZG3/4 |
3600L/H 1,5bar~4bar ZG1 |
4800L/H 1,5bar~4bar ZG1 |
9m³/H 1,5bar~4bar DN40 |
10m³/H 1,5bar~4bar DN50 |
15m³/H 1,5bar~4bar DN50 |
20m³/H 1,5bar~4bar DN65 |
32m³/H 1,5bar~4bar DN80 |
46m³/H 1,5bar~4bar DN100 |
|
Dimensão cm | 45*70*160 | 45*70*160 | 55*70*175 | 55*70*175 | 65*85*185 | 70*85*185 | 80*120*185 | 150*100*185 | 200*145*205 | 200*145*205 | 250*145*225 | 300*160*225 | |
Peso kg | 160 | 180 | 195 | 260 | 320 | 390 | 620 | 820 | 1100 | 1350 | 1680 | 2250 | |
Power 380V 50hz | AC220V 4kW | 7kW | 9kW | 13kW | 16kW | 26kW | 42kW | 57kW | 82kW | 136kW | 183kW | 309kW | |
Case materia | Cold rolled steel powder coating (standard color 7035) | ||||||||||||
Opcional | Optional Ethernet interface and computer operation software configuration | ||||||||||||
Opcional | Outside touch screen display controller, the communication line distance is 10 meter |
||||||||||||
OptionalPower | 110V 50HZ single-phase, 110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ 3-phase, 440V~460V 60HZ 3-phase | ||||||||||||
Opcional | SUNDI series can provide optional medium temperature control accuracy of ± 0.1 ℃ and material temperature control accuracy of ± 0.1 ℃ within a heating power of 25kW |
Modelo | SUNDI-625 SUNDI-625W |
SUNDI-635 SUNDI-635W |
SUNDI-655 SUNDI-655W |
SUNDI-675 SUNDI-675W |
SUNDI-6A10 SUNDI-6A10W |
SUNDI-6A15W | SUNDI-6A25W | SUNDI-6A38W | SUNDI-6A60W | |
Gama de temperaturas | -60℃~+250℃ | |||||||||
Modo de controlo | Feedback PID + O nosso cálculo de controlo dinâmico especial, controlador PLC | |||||||||
Controlo da temperatura | Controlo da temperatura do processo e modelo de controlo da temperatura da camisa | |||||||||
Temp difference | Definir ou controlar a diferença de temperatura entre o óleo de revestimento e o processo da matéria-prima | |||||||||
Editor de programas | 20 programs, each program can edit 40 steps | |||||||||
Communication Protoco | Protocolo MODBUS RTU, interface RS485 | |||||||||
Material temp feedback | PT100 | |||||||||
Feedback da temperatura | The temp of 3 points: the inlet and outlet of equipment,reactor material temperature(external temp. sensor) | |||||||||
Medium temp accuracy | ±0.5℃ | |||||||||
Material temp accuracy | ±1℃ | |||||||||
Potência de aquecimento | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | |
Capacidade de arrefecimento | 250℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 |
100℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | |
20℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | |
-40℃ | 0.95 | 1.45 | 2.3 | 3.1 | 4.8 | 7.8 | 18 | 23 | 31 | |
-55℃ | 0.25 | 0.5 | 0.75 | 0.9 | 1.5 | 2.8 | 6 | 8 | 11 | |
Flow、pressuremax L/min bar | 20 | 35 | 35 | 50 | 60 | 110 | 150 | 200 | 250 | |
1.2 | 1.2 | 1.2 | 1.2 | 1.5 | 1.5 | 1.5 | 1.5 | 2.5 | ||
Bomba de circulação | Bomba de acionamento magnético | |||||||||
Compressor | Tecumseh/Emerson copeland/Carlyle | |||||||||
Válvula de expansão | Válvula de expansão eletrónica | |||||||||
Evaporador | Permutador de calor de placas | |||||||||
Painel de operações | Ecrã tátil de 7 polegadas , mostrar curva de temperatura \ saída de dados EXCEL | |||||||||
Proteção de segurança | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, high temperature protection and temperature fault protection. |
|||||||||
Sistema de circulação fechado | Todo o sistema é de circulação totalmente fechada, não há névoa de óleo a alta temperatura e não há vapor de água a baixa temperatura, a pressão não sobe quando o sistema está a funcionar. O sistema fornecerá óleo automaticamente a baixa temperatura. | |||||||||
Refrigerante | R-404A/R23 | |||||||||
Tamanho da ligação | ZG1/2 | ZG3/4 | ZG3/4 | ZG1 | ZG1 | ZG1 | DN32 | DN40 | DN50 | |
Água de arrefecimento @20℃ |
1100L/H 1,5bar~4bar ZG1/2 |
2000L/H 1,5bar~4bar ZG3/4 |
2300L/H 1,5bar~4bar ZG3/4 |
2600L/H 1,5bar~4bar ZG3/4 |
3300L/H 1,5bar~4bar ZG1 |
4000L/H 1,5bar~4bar ZG1 1/4 |
8,5 m³/H 1,5bar~4bar DN40 |
14m³/H 1,5bar~4bar DN50 |
20m³/H 1,5bar~4bar DN65 |
|
Dimensão cm | 55*70*175 | 55*70*175 | 55*70*175 | 65*85*185 | 65*85*185 | 80*120*185 | 150*100*185 | 200*145*205 | 200*145*205 | |
Peso kg | 205 | 225 | 300 | 340 | 380 | 380 | 980 | 1350 | 1580 | |
Potência 380V 50HZ | 5kW | 10kW | 12kW | 18kW | 22kW | 28kW | 56kW | 73kW | 110kW | |
Case materia | Cold rolled steel powder coating (standard color 7035) | |||||||||
Opcional | Optional Ethernet interface and computer operation software configuration | |||||||||
Opcional | Outside touch screen display controller, the communication line distance is 10 meter |
|||||||||
OptionalPower | 110V 50HZ single-phase, 110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ 3-phase, 440V~460V 60HZ 3-phase | |||||||||
Opcional | SUNDI series can provide optional medium temperature control accuracy of ± 0.1 ℃ and material temperature control accuracy of ± 0.1 ℃ within a heating power of 25kW |
Modelo | SUNDI-825W | SUNDI-835W | SUNDI-855W | SUNDI-875W | SUNDI-8A10W | SUNDI-8A15W | SUNDI-8A25W | SUNDI-8A38W | SUNDI-8A60W | SUNDI-8A80W | |
Gama de temperaturas | -80℃~+250℃ | ||||||||||
Modo de controlo | Feedback PID + O nosso cálculo de controlo dinâmico especial, controlador PLC | ||||||||||
Controlo da temperatura | The material temperature control and equipment outlet temperature control modes can be freely selected | ||||||||||
Temp difference | Definir ou controlar a diferença de temperatura entre o óleo de revestimento e o processo da matéria-prima | ||||||||||
Editor de programas | 20 programs, each program can edit 40 steps | ||||||||||
Communication Protoco | Protocolo MODBUS RTU, interface RS485 | ||||||||||
Material temp feedback | PT100 | ||||||||||
Feedback da temperatura | The temp of 3 points: the inlet and outlet of equipment,reactor material temperature(external temp. sensor) | ||||||||||
Medium temp accuracy | ±0.5℃ | ||||||||||
Material temp accuracy | ±1℃ | ||||||||||
Potência de aquecimento | 3 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 80 | |
Capacidade de arrefecimento | 250℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 80 |
20℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 80 | |
-60℃ | 1 | 1.4 | 1.6 | 3 | 3.5 | 5.8 | 10 | 16 | 23 | 32 | |
-75℃ | 0.3 | 0.42 | 0.7 | 1.3 | 1.5 | 2.4 | 5 | 8 | 11 | 16 | |
Flow、pressuremax L/min bar |
20 | 35 | 35 | 50 | 60 | 110 | 150 | 250 | 400 | 400 | |
1.2 | 1.2 | 1.2 | 1.2 | 1.5 | 1.5 | 1.5 | 1.5 | 2.5 | 2.5 | ||
Bomba de circulação | Bomba de acionamento magnético | ||||||||||
Compressor | Emerson copeland/Carlyle | ||||||||||
Válvula de expansão | Válvula de expansão eletrónica | ||||||||||
Evaporador | Permutador de calor de placas | ||||||||||
Painel de operações | Ecrã tátil de 7 polegadas , mostrar curva de temperatura \ saída de dados EXCEL | ||||||||||
Proteção de segurança | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, high temperature protection and temperature fault protection. |
||||||||||
Sistema de circulação fechado | Todo o sistema é de circulação totalmente fechada, não há névoa de óleo a alta temperatura e não há vapor de água a baixa temperatura, a pressão não sobe quando o sistema está a funcionar. O sistema fornecerá óleo automaticamente a baixa temperatura. | ||||||||||
Refrigerante | R-404A/R508B | ||||||||||
Tamanho da ligação | ZG1/2 | ZG3/4 | ZG3/4 | ZG1 | ZG1 | ZG1 | DN32 | DN40 | DN65 | DN65 | |
Água de arrefecimento @20℃ |
1800L/H 1,5bar~4bar ZG3/4 |
2000L/H 1,5bar~4bar ZG3/4 |
2800L/H 1,5bar~4bar ZG3/4 |
3500L/H 1,5bar~4bar ZG1 |
4200L/H 1,5bar~4bar ZG1 |
5600L/H 1,5bar~4bar DN32 |
10m³/H 1,5bar~4bar DN40 |
18m³/H 1,5bar~4bar DN65 |
28m³/H 1,5bar~4bar DN80 |
30m³/H 1,5bar~4bar DN80 |
|
Dimensão cm | 55*70*175 | 55*70*175 | 65*85*185 | 70*85*185 | 70*85*185 | 80*120*185 | 150*100*185 | 200*145*205 | 245*170*225 | 300*160*225 | |
Peso kg | 240 | 285 | 345 | 500 | 600 | 950 | 1300 | 1550 | 2200 | 2850 | |
Potência 380V 50HZ | 9,5 kW | 11kW | 17kW | 20kW | 26kW | 36kW | 59kW | 98kW | 135kW | 177kW | |
Case materia | Cold rolled steel powder coating (standard color 7035) | ||||||||||
Opcional | Optional Ethernet interface and computer operation software configuration | ||||||||||
Opcional | Outside touch screen display controller, the communication line distance is 10 meter |
||||||||||
OptionalPower | 110V 50HZ single-phase, 110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ 3-phase, 440V~460V 60HZ 3-phase | ||||||||||
Opcional | SUNDI series can provide optional medium temperature control accuracy of ± 0.1 ℃ and material temperature control accuracy of ± 0.1 ℃ within a heating power of 25kW |
Modelo | SUNDI-955W | SUNDI-975W | SUNDI-9A10W | SUNDI-9A15W | SUNDI-9A25W | SUNDI-9A38W | SUNDI-9A60W | SUNDI-9A80W | |
Gama de temperaturas | -90℃~+250℃ | ||||||||
Modo de controlo | Feedback PID + O nosso cálculo de controlo dinâmico especial, controlador PLC | ||||||||
Controlo da temperatura | Controlo da temperatura do processo e modelo de controlo da temperatura da camisa | ||||||||
Temp difference | Definir ou controlar a diferença de temperatura entre o óleo de revestimento e o processo da matéria-prima | ||||||||
Editor de programas | 20 programs, each program can edit 40 steps | ||||||||
Communication Protoco | Protocolo MODBUS RTU, interface RS485 | ||||||||
Material temp feedback | PT100 | ||||||||
Feedback da temperatura | The temp of 3 points: the inlet and outlet of equipment,reactor material temperature(external temp. sensor) | ||||||||
Medium temp accuracy | ±0.5℃ | ||||||||
Material temp accuracy | ±1℃ | ||||||||
Potência de aquecimento | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 80 | |
Capacidade de arrefecimento | 250℃ | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 80 |
0℃ | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 80 | |
-60℃ | 2.8 | 3.2 | 4.2 | 6 | 10 | 16 | 24 | 32 | |
-80℃ | 0.8 | 1.2 | 1.6 | 2.1 | 3.5 | 6 | 11 | 15 | |
-85℃ | 0.5 | 0.7 | 0.85 | 1.3 | 1.9 | 3.5 | 6 | 8 | |
Flow、pressure max L/min bar |
35 | 50 | 60 | 110 | 150 | 250 | 400 | 400 | |
1.2 | 1.2 | 1.5 | 1.5 | 1.5 | 1.5 | 2.5 | 2.5 | ||
Bomba de circulação | Bomba de acionamento magnético | ||||||||
Compressor | Emerson copeland/Carlyle | ||||||||
Válvula de expansão | Válvula de expansão eletrónica | ||||||||
Evaporador | Permutador de calor de placas | ||||||||
Painel de operações | Ecrã tátil de 7 polegadas , mostrar curva de temperatura \ saída de dados EXCEL | ||||||||
Proteção de segurança | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, high temperature protection and temperature fault protection. |
||||||||
Sistema de circulação fechado | Todo o sistema é de circulação totalmente fechada, não há névoa de óleo a alta temperatura e não há vapor de água a baixa temperatura, a pressão não sobe quando o sistema está a funcionar. O sistema fornecerá óleo automaticamente a baixa temperatura. | ||||||||
Refrigerante | R-404A/R508B | ||||||||
Tamanho da ligação | ZG3/4 | ZG1 | ZG1 | ZG1 | DN32 PN10 | DN40 PN10 | DN65 PN10 | DN65 PN10 | |
Água de arrefecimento @20℃ |
3400L/H 1,5bar~4bar ZG1 |
4500L/H 1,5bar~4bar ZG1 |
5200L/H 1,5bar~4bar ZG1 1/4 |
8m³/H 1,5bar~4bar DN40 |
12m³/H 1,5bar~4bar DN50 |
20m³/H 1,5bar~4bar DN65 |
30m³/H 1,5bar~4bar DN80 |
40m³/H 1,5bar~4bar DN100 |
|
Dimensão cm | 80*120*185 | 80*120*185 | 80*120*185 | 150*100*185 | 200*145*205 | 200*145*205 | 250*160*225 | 300*160*225 | |
Peso kg | 365 | 570 | 680 | 950 | 1400 | 1750 | 2400 | 3150 | |
Potência 380V 50HZ | 16kW | 27kW | 30kW | 42kW | 59kW | 83kW | 130kW | 188kW | |
Case materia | Cold rolled steel powder coating (standard color 7035) | ||||||||
Opcional | Optional Ethernet interface and computer operation software configuration | ||||||||
Opcional | Outside touch screen display controller, the communication line distance is 10 meter |
||||||||
OptionalPower | 110V 50HZ single-phase, 110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ 3-phase, 440V~460V 60HZ 3-phase | ||||||||
Opcional | SUNDI series can provide optional medium temperature control accuracy of ± 0.1 ℃ and material temperature control accuracy of ± 0.1 ℃ within a heating power of 25kW |
Modelo | SUNDI-1055W | SUNDI-1075W | SUNDI-10A10W | SUNDI-10A15W | SUNDI-10A25W | SUNDI-10A38W | SUNDI-10A60W | SUNDI-10A80W | |
Gama de temperaturas | -100℃~+100℃ | ||||||||
Modo de controlo | Feedback PID + O nosso cálculo de controlo dinâmico especial, controlador PLC | ||||||||
Controlo da temperatura | Controlo da temperatura do processo e modelo de controlo da temperatura da camisa | ||||||||
Temp difference | Definir ou controlar a diferença de temperatura entre o óleo de revestimento e o processo da matéria-prima | ||||||||
Editor de programas | 20 programs, each program can edit 40 steps | ||||||||
Communication Protoco | Protocolo MODBUS RTU, interface RS485 | ||||||||
Material temp feedback | PT100 | ||||||||
Feedback da temperatura | The temp of 3 points: the inlet and outlet of equipment,reactor material temperature(external temp. sensor) | ||||||||
Medium temp accuracy | ±0.5℃ | ||||||||
Material temp accuracy | ±1℃ | ||||||||
Potência de aquecimento | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 80 | |
Capacidade de arrefecimento | 100℃ | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 80 |
0℃ | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 80 | |
-80℃ | 2.8 | 3.4 | 4.1 | 5 | 8 | 13 | 22 | 30 | |
-90℃ | 1.2 | 1.6 | 2 | 3 | 4.8 | 7.5 | 12 | 16 | |
-95℃ | 0.7 | 0.9 | 1.2 | 1.8 | 2.9 | 4.5 | 7.2 | 9.5 | |
Flow、pressure max L/min bar |
35 | 50 | 60 | 110 | 150 | 250 | 400 | 400 | |
1.2 | 1.2 | 1.5 | 1.5 | 1.5 | 1.5 | 2.5 | 2.5 | ||
Bomba de circulação | Bomba de acionamento magnético | ||||||||
Compressor | Emerson copeland/Carlyle | ||||||||
Válvula de expansão | Válvula de expansão eletrónica | ||||||||
Evaporador | Permutador de calor de placas | ||||||||
Painel de operações | Ecrã tátil de 7 polegadas , mostrar curva de temperatura \ saída de dados EXCEL | ||||||||
Proteção de segurança | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, high temperature protection and temperature fault protection. |
||||||||
Sistema de circulação fechado | Todo o sistema é de circulação totalmente fechada, não há névoa de óleo a alta temperatura e não há vapor de água a baixa temperatura, a pressão não sobe quando o sistema está a funcionar. O sistema fornecerá óleo automaticamente a baixa temperatura. | ||||||||
Refrigerante | R-404A/R23/R14 | ||||||||
Tamanho da ligação | ZG3/4 | ZG1 | ZG1 | DN32 | DN32 | DN40 | DN65 | DN65 | |
Água de arrefecimento @20℃ |
5000L/H 1.5~4bar ZG1 1/4 |
7000L/H 1.5~4bar DN40 |
9000L/H 1.5~4bar DN40 |
12m³/H 1.5~4bar DN50 |
20m³/H 1.5~4bar DN65 |
25m³/H 1.5~4bar DN65 |
40m³/H 1.5~4bar DN80 |
50m³/H 1.5~4bar DN100 |
|
Dimensão cm | 80*120*185 | 150*100*185 | 150*100*185 | 200*145*205 | 200*145*205 | 250*160*225 | 300*160*225 | 400*160*225 | |
Peso kg | 565 | 705 | 890 | 1250 | 1600 | 2100 | 2950 | 3350 | |
Potência 380V 50HZ | 26W | 28kW | 37kW | 49kW | 69kW | 82kW | 170kW | 200kW | |
Case materia | Cold rolled steel powder coating (standard color 7035) | ||||||||
Opcional | Optional Ethernet interface and computer operation software configuration | ||||||||
Opcional | Outside touch screen display controller, the communication line distance is 10 meter |
||||||||
Potência opcional | 110V 50HZ single-phase, 110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ 3-phase, 440V~460V 60HZ 3-phase | ||||||||
Opcional | SUNDI series can provide optional medium temperature control accuracy of ± 0.1 ℃ and material temperature control accuracy of ± 0.1 ℃ within a heating power of 25kW |
PRINCÍPIO DE FUNCIONAMENTO

A tecnologia de resfriamento de temperatura ultra-alta pode resfriar diretamente a partir de uma alta temperatura de 300 ℃ [porque apenas o meio de transferência de calor na câmara de expansão entra em contato com o oxigênio no ar (e a temperatura do tanque de expansão está entre a temperatura normal e 60 ℃), o que pode reduzir o risco de o meio de transferência de calor ser oxidado e absorver água no ar. Em alta temperatura, nenhum meio condutor de calor evapora, e o controle contínuo de temperatura de - 80 ℃ ~ 190 ℃, - 70 ℃ ~ 220 ℃, - 88 ℃ ~ 170 ℃, - 55 ℃ ~ 250 ℃ e - 30 ℃ ~ 300 ℃ pode ser realizado sem pressurização.
Controlo do ecrã a cores

1. Apresenta todos os tipos de temperaturas de controlo do processo.
2. Mostra o nível de líquido do fluido condutor de calor no vaso de expansão.
3. Mostra a indicação do funcionamento do sistema de refrigeração.
4. Mostra a indicação de funcionamento do aquecedor.
5. Mostra a indicação de funcionamento da bomba de circulação.
6. Apresenta o controlo da temperatura (padrão de controlo da temperatura dos materiais, controlo da temperatura média condutora de calor).
7. O controlo do limite superior e inferior da temperatura pode ser definido.
8. A diferença de temperatura entre a camisa e o material do reator pode ser definida.
9. Mostra o alarme para adicionar o líquido quando este estiver vazio.
10. O compressor de refrigeração pode ser regulado para funcionar manual ou automaticamente.
Customized solutions to meet your temperature process needs
CUSTOM CHILLER SIZES
Whether it is portable, compact, large and small chillers, we can custom design them according to your requirements. No matter how many tons of chiller you need, we can create the best solution.
CUSTOM CHILLER TYPES
We provide chillers of various refrigeration types, including but not limited to air-cooled, water-cooled and evaporative-condensing chillers. Regardless of the type of refrigeration compressor, we can design it according to your requirements.
CUSTOM TEMPERATURE RANGES
We can create a custom solution for temperatures from -150℃ to +350℃. Custom temperature ranges for specific industries.
CUSTOM CHILLER VOLTAGE
Customize chiller voltage and phase according to your needs. Optional 110V/60HZ, 220V/60HZ, 380V/50HZ, 220V/50HZ, 400V/50HZ, 460V/60HZ, 440V~480V/60HZ, etc.
Why choose lneya as your temperature control supplier?
Years of experience
Satisfied Customers
m² Production Area
Patented Technologies
Visit LNEYA factory
contactar-nos
Envie-nos o seu pedido e entraremos em contacto consigo no prazo de 24 horas
Recomendar produtos