Operation and Maintenance of Small Water Chiller Units
2. Air-cooled module internal filter, in order to better filter impurities in the water system, the protective plate heat exchanger is generally more than 40 meshes, that is to say, its filter is more dense and finer than other brands. The advantage of this method is that it can filter impurities better, and the disadvantage is that the number of cleaning increases. But compared with the air-cooled module machine, the closed circulating water system can better ensure the cleaning of the water system in the future as long as the filters are cleaned in time during the initial operation.
3. Inspection and cleaning of end filters. Water filters are installed in both air conditioning boxes and fan coil units at the end. These water filters need to be checked and cleaned, which is also an indirect reason affecting the water system and can improve the cooling effect of the end.
4. We can’t start it forcibly. We are used to turning it on when something goes wrong. In fact, it is a serious operation error for water chiller, especially the frequent power failure and reset of the chiller, which results in the failure of protection, just like a car with frequent high water temperature failure and failure to deal with it, which eventually leads to the breakdown.
Our company provides pequenas unidades de refrigeração de água, welcome to buy!
Recomendações relacionadas
-
Liquid Cooled Battery Pack BMS Test Cooling Water Circulator
1219As the temperature gradually increases, the use of the cooling water circulator for the BMS test of the liquid-cooled battery pack also gradually peaks. The rated power of the cooling water circulator for BMS testing of liquid-cooled battery packs...
Ver pormenores -
Sistema de aquecimento de arrefecimento de reator para fábrica farmacêutica
9731.requisitos do processo: 2.Compatibilidade com o meio: 3.Gama de temperaturas: 4.Requisitos de limpeza: 5.Espaço e manutenção: Em resumo, t...
Ver pormenores -
Como evitar que a pressão de congelação da caixa de congelação rápida de rolamentos seja demasiado baixa?
1138No sistema de refrigeração do chiller de rolamento, se a instalação do condensador não estiver no espaço fechado, a pressão de escape do sistema (pressão de condensação) tende a ser menor no inverno (ou baixa temperatura), o que é muitas vezes mais commo...
Ver pormenores -
Controlo de simulação da variação de temperatura no sistema de controlo da temperatura de arrefecimento e aquecimento do
811O sistema de controlo da temperatura de arrefecimento e aquecimento industrial é um equipamento de controlo da temperatura utilizado no processo de arrefecimento e aquecimento da caldeira de reação na indústria farmacêutica e química. Quais são as caraterísticas do equipamento da lneya?...
Ver pormenores