What are the advantages and disadvantages of thermal oil heating circulators?

The heat conduction oil heating circulator adopts a fully closed loop structure to directly act on the heat energy to the heated medium.
Its advantages are:
(1) Due to the continuous renewal of the heat transfer surface, the heat loss is small;
(2) The temperature field distribution state of the medium can be changed during operation;
(3) Multiple units can be used in parallel. The closed circulation system has a wide range of applications, such as various boilers, industrial furnaces, air preheaters, dryers, ovens and other places that require heat transfer.
But it also has many shortcomings, mainly as follows:
(1) Air resistance is easy to occur when there is gas or liquid in the system;
(2) It is not easy to realize automatic control and remote control;
(3) It is difficult to adapt to high temperature and high pressure occasions.
LNEYA’s thermal oil heating circulator adopts the complete cooling process to achieve 300°C~50°C cooling, which can continuously increase and decrease the temperature. There is no oil mist volatilization at high temperature, and the heat transfer oil will not be oxidized and browned. It has the function of correcting the internal circulation temperature probe PT100. With safety protection functions, such as self-diagnosis, high-voltage pressure switch, overload relay, thermal protection device, etc. When the system is running, the pressure will not increase due to high temperature, and the heat transfer medium will be automatically replenished at low temperature.
Recomendações relacionadas
-
Descrição da fonte de alimentação do chip condutor no sistema de controlo da temperatura de ensaio de chips
895O sistema de controlo de temperatura de teste de chip é principalmente para o equipamento de teste de fonte de calor frio para vários chips de unidade. Antes da operação do sistema de controlo de temperatura de teste de chips Wuxi Guanya, o utilizador precisa de conhecer a potência do chip de acionamento. I...
Ver pormenores -
-
Precauções para a utilização do refrigerador de recirculação da LNEYA
1134LNEYA's low temperature recirculating chillercan be used with supporting instruments (such as rotary evaporators,fermentation tanks, chemical reactors, freeze-drying equipment,biopharmaceutical reactors, etc.), with large cooling capacity and f...
Ver pormenores -
Selection of Temperature Control System for Laboratory Resin Reaction Kettle
10181. Choose from the quality of the laboratory resin reactor temperature control system: can affect the quality of the laboratory resin reactor temperature control system, may be the use of accessories. There are some small factories on the market t...
Ver pormenores