How to Choose Water Chiller Units in Small Factories
Professional water chiller factory said that the quality of equipment can be seen from the three main components of pequenas unidades de refrigeração de água. The most important one is the compressor, which is the heart of the unit and the most critical component. A good compressor should not only run stably, but also ensure good energy efficiency.
Evaporator and condenser are also one of the main components of water chiller. Evaporator and condenser play the role of heat absorption and exothermic respectively. Adequate and appropriate heat transfer can give full play to the efficiency of compressor. If the heat transfer capacity of the condenser is insufficient, it will directly affect the refrigeration effect of the unit. In summer, the high pressure is easy to occur, and even the protection shutdown of the chiller is caused by the high pressure exceeding the standard. The heat transfer of evaporator is more important. The insufficient heat transfer will not only cause the inefficiency of the unit, but also make the refrigerant unable to evaporate completely. It will directly return to the compressor to cause liquid hammer and damage the compressor, thus making the whole chiller unusable.
Another main component is the expansion valve, which is not only a flow regulating valve but also a throttle valve in refrigeration equipment in the refrigeration system of water cooler. The main function is to reduce the pressure and throttle the refrigerant liquid flowing through the thermodynamic expansion valve at high pressure and normal temperature, and to change it into low temperature and low pressure refrigerant wet vapor, which enters the evaporator and vaporizes and absorbs heat in the evaporator, so as to achieve the purpose of refrigeration and cooling.
Small factories should pay attention to the following three points when choosing and purchasing:
1. Selection of key parts for chillers.
Compressor is the main index affecting the performance of shadow water chiller. In order to control the overall production cost, many water chiller manufacturers adopt poor quality products in compressor and other major parts, and even use retrofitted compressors, which seriously affects the later use efficiency of industrial water chillers, resulting in increasing energy consumption.
2. Controlling the purchase cost.
On the premise of guaranteeing chiller’s main energy, it can achieve the goal of reducing cost and satisfying enterprise’s production demand with the least capital by purchasing industrial chiller products at a higher cost performance ratio.
3. Purchase chillers according to the environment used by enterprises.
Water quality and air quality have a certain impact on the operation of water chillers. It is necessary to inform the water quality and air quality of the position of the water chiller manufacturer’s own enterprise in advance.
Recomendações relacionadas
-
Como eliminar o alarme de alta pressão do congelador industrial de temperatura ultrabaixa?
1412Durante a utilização, se uma falha não for resolvida a tempo, afectará a utilização do congelador industrial de temperatura ultra baixa. Como resolver o problema do alarme de alta pressão? Se o congelador industrial de temperatura ultrabaixa arrefecido a água apresentar um alarme de alta pressão...
Ver detalhes -
O equipamento mecânico de montagem a frio é dedicado ao processamento a frio da montagem de peças metálicas
1462O equipamento mecânico de montagem a frio é um método de processamento de peças de trabalho a temperaturas abaixo de -130 ℃. O tratamento criogénico pode melhorar significativamente a tenacidade da peça de trabalho sem reduzir a resistência e a dureza da peça de trabalho.
Ver detalhes -
What are the temperature control performance of laboratory recirculating chillers
1719The laboratory recirculating chiller is atypical cooling circulator with heating function to ensure the repeatability oflaboratory results. There are water-cooled or air-cooled refrigerators, whichcan be placed in a laboratory fume hood or set ...
Ver detalhes -
Introdução e vantagens do sistema de refrigeração criogénica
1863O refrigerador criogênico de fluido único de tamanho médio produzido por nossa empresa tem uma faixa de temperatura de resfriamento de -150 ℃ a -5 ℃, velocidade de resfriamento rápida, segura e confiável, usada para resfriamento líquido rápido, aplicada a alta tecnologia, como bioquímica, congelamento ...
Ver detalhes
LNEYA Refrigeradores industriais Fabricante Fornecedor