Troubleshooting of refrigeration system failure of material aging test equipment at low temperature
Regular maintenance work for the material low temperature and high temperature aging test system, and troubleshooting of the refrigeration system is also very important. Here are a few tips.
1. Exhaust at double high pressure, heat dissipation may be problematic.
When it is detected that the high and low pressure of the system are higher than normal, it is usually because there is air in the system or excessive refrigerant is added. At this time, it is necessary to re-evacuate and add proper amount of refrigerant to solve the problem. But there is another situation, that is, poor heat dissipation, especially when the ambient temperature is relatively high, which often results in worse heat dissipation. The cause of this failure is generally that the heat sink is blocked, dirty, and the speed of the heat dissipation fan is not enough.
2. Refrigerant with low pressure loss, otherwise the system will be blocked.
When the high and low pressures are both low, there are two possibilities:
(1) If the system is blocked, the blocked part will produce throttling, and there will be a significant temperature difference in the throttling part, and the problem can be found by feeling it with your hands.
(2) The leakage of refrigerant leads to insufficient refrigerant. This situation is more common. At this time, the material’s low temperature and high temperature aging test equipment detector must be used to find out the leaking location and perform replacement.
3. Replace the compressor with low pressure, high pressure and low pressure.
When the pressure gauge of the material low temperature and high temperature aging test equipment detects that the low pressure is higher than normal, and the high pressure is lower than normal, at this time, it is recommended that the chiller refrigeration cannot achieve the effect of the normal material low temperature and high temperature aging test equipment. The reason is likely to be wear in the pump, resulting in a drop in power. At this time, it is often necessary to replace the compressor to solve the problem.
4. There is water vapor in the meter shake system, so it must be changed when it is exhausted.
When the refrigeration system of the material low temperature and high temperature aging test equipment is working, if the pressure gauge needle keeps shaking, it means that the system has moisture. To solve this problem, it is generally necessary to re-evacuate, and the pumping time must be no less than 15 minutes. If necessary, the drying bottle needs to be replaced to drain the water in the system.
Recomendações relacionadas
-
Operação e manutenção de pequenas unidades de refrigeradores de água
14152. Filtro interno do módulo arrefecido a ar, para filtrar melhor as impurezas do sistema de água, o permutador de calor de placas de proteção tem geralmente mais de 40 malhas, ou seja, o seu filtro é mais denso e mais fino do que o de outras marcas. A vantagem...
Ver detalhes -
Aplicação de TCU em sistemas de refrigeração e de circulação de calor
1842No processo de síntese farmacêutica e operação de química fina, encontramos frequentemente reacções exotérmicas fortes, como a reação de oxidação e a neutralização ácido-base. No caso destas reacções exotérmicas fortes, se o controlo for inadequado ou a...
Ver detalhes -
How to choose the chiller for cooling the mixing tank?
1933Mixing tanks are used in coatings, medicine, building materials, chemicals, pigments, resins, food, scientific research and other industries to stir, mix, blend, and homogenize materials. The mixing tank will generate heat during the mixing proc...
Ver detalhes -
O método que o pequeno chiller refrigerado a água precisa de seguir ao carregar o refrigerante
1752Na nossa vida, acreditamos que toda a gente está muito familiarizada com a refrigeração. No ar condicionado central e na indústria de arrefecimento de processos de produção industrial, os pequenos chillers arrefecidos a água são mais comuns. Esta unidade é composta por um compressor no interior...
Ver detalhes
LNEYA Refrigeradores industriais Fabricante Fornecedor