How to choose a heating and cooling circulating...

How to choose a heating and cooling circulating water bath?

2024-03-19

Heating and recirculating water bath In the process of selection, heating power, cooling power, pressure and flow are also factors that users need to consider. Good system design and accessory brand selection are related to the whole heating and cooling cycle water bath selection. As far as the heat transfer medium of the heating and cooling cycle water bath is concerned, water is used as a heat transfer medium, which is economical and environmentally friendly. Even if a leak occurs, it can b...

Ver detalhes
Manutenção básica de equipamentos de alta e baixa temperatura...

Manutenção básica de bombas de circulação de refrigeração de alta e baixa temperatura

2024-03-19

Properly perform the sequence of opening and closing of the high and low temperature refrigeration cycle pump group to ensure normal operation after the host is started. Note that the condenser heats up well, otherwise the high temperature protection device of the high and low temperature refrigeration cycle pump group will stop and even cause malfunction due to the condensing temperature and the corresponding condensing pressure being too high. The cold water in the evaporator should be circ...

Ver detalhes
Sistema de aquecimento por refrigeração LNEYA star SUNDI-3...

Sistema de aquecimento por refrigeração LNEYA star SUNDI-320/420W/430W

2024-03-19

Today, I will introduce the model of LNEYA's refrigeration heating system: SUNDI-320/420W/430W. It has three kinds of medium temperature range: -30°C~180°C; -40°C~180°C; -40°C~200°C. The control system is programmed to program up to 10 programs, each of which can be programmed in 42 steps. The temperature feedback of the equipment is: equipment inlet temperature, equipment outlet temperature, reactor material temperature (external temperature sensor) three-point temperature. Typical applic...

Ver detalhes
Small temperature control system equipment weld...

Small temperature control system equipment welding maintenance precautions

2024-03-19

Small thermostat control system equipment pay attention to the point of comparison when repairing, LNEYA professional manufacturers reminded that the welding part is also one of the key points of maintenance, then what aspects should be paid attention to when welding? When the small-scale thermostat control system equipment is welded, protective measures should be taken for the chassis and various components to prevent the flame from being burned by the torch. When welding, pay attention to t...

Ver detalhes
Como escolher a bomba de acessórios na nova ene...

Como escolher a bomba acessória no ensaio de baterias de veículos de energia nova?

2024-03-19

New energy vehicle battery testing plays a more important role in the development of new energy vehicles. In the operation process, the pump is the key supporting equipment in the LNEYA test equipment, which is also concerned by people. So how to choose the pump? The type and model of the pump in the new energy vehicle battery test need to meet the calculated flow, pressure, temperature and other industries, need to meet specific media characteristics requirements, for the specific substance ...

Ver detalhes
Ethylene glycol refrigeration unit made a stron...

Ethylene glycol refrigeration unit made a strong attack and created LNEYA brand in 12 years

2024-03-19

Performance enhanced positioning When performing the cooling and heating reaction, in many cases, the refrigerant cannot cool the object to be cooled by itself. Therefore, we need a coolant (or refrigerant) to cool the refrigeration system in a relatively small range. The suitable brine is undoubtedly ethylene glycol. Compared with water, the freezing point is high and the salt water is corrosive. Ethylene glycol is currently a suitable refrigerant for everyone. Therefore, in response to this...

Ver detalhes
Effect of evaporator on refrigeration system in...

Effect of evaporator on refrigeration system in special instrument for low temperature experiment

2024-03-19

The low temperature experiment special instrument is LNEYA's refrigeration heating equipment for the laboratory. The importance of the evaporator is self-evident. So what effect does the evaporator have on the refrigeration system? According to different models, the choice of evaporators for low-temperature experiment special instruments is also different, such as box-type low temperature experiment special instruments, using water tank coil evaporator; open low temperature experiment special...

Ver detalhes
Como poupar energia no frigorífico de câmara de vácuo...

Como poupar energia na unidade de controlo do termóstato de aquecimento e refrigeração da câmara de vácuo

2024-03-19

In the environment of energy-saving and emission-reduction operation, how to operate the LNEYA vacuum chamber cooling and heating thermostat control unit is very important. Let's take a look at a few tips to reduce the consumption and see how to use it. The very important first step in the selection of the vacuum chamber cooling and heating thermostat control unit is that the cooling capacity is too small, which affects the production, and often loses more than the loss; however, the excessiv...

Ver detalhes
Princípio de refrigeração do congelador de rolamentos LNEYA d...

Descrição do princípio de refrigeração do congelador de rolamentos LNEYA

2024-03-19

LNEYA industrial freezer can be used in the refrigeration process of the bearing industry. Since the use of bearing freezer is relatively large, the performance is very important, so let's talk about the principle today. The refrigerant in the bearing freezer circulates in the refrigeration system under the action of the mechanical energy generated by the compressor, and is repeatedly operated in a gaseous state or a liquid state. During this process, the refrigerant continuously absorbs the ...

Ver detalhes
Closed circulation cooling system debugging att...

Closed circulation cooling system debugging attention note

2024-03-19

Closed circulation cooling system needs to pay attention to some common problems during commissioning. Do a good job in debugging work. LNEYA manufacturers remind users that only when they are ready to work can they be better debugged. The preparation work before the commissioning of the closed circulation cooling system is an important part of the debugging process, which may affect the progress of the whole debugging process. Generally, it is necessary to pay attention to the leakage detect...