Instruções de utilização do frigorífico criogénico industrial
Os frigoríficos industriais são uma das máquinas de água fria. São classificados de acordo com o modo de arrefecimento da própria máquina de água fria. Dividem-se em frigoríficos de refrigeração a ar e frigoríficos de refrigeração a água. Caraterísticas estruturais: a ...
Structural features: a standard refrigerator freezer is composed of a compressor, condenser, evaporator, filter drier, expansion throttling valve of the five most series, note the amount of refrigerant inside (refrigerant), the electrical appliances (including controller) according to the requirement of the environment and control the operation of the compressor to achieve the purpose of heat transfer and refrigeration.
With the progress of the society, the industry has also been developed rapidly. Today, we will discuss the use of the laboratory refrigerator (industrial refrigerator).
1. Always check the sealing strip of the outer door.
2. Place it firmly and horizontally on the ground when carrying.
3. Clean the filter once a month (use a vacuum cleaner to suck, rinse it with water, finally dry and reset the filter), and suck the dust on the internal condenser with a vacuum cleaner in every two months.

4. When defrosting, you should cut off the power and open the door. When the ice and cream begin to melt, put in each layer of the refrigerator clean and bibulous cloth.
5. Clean it every month to make sure it is clean.
6. Remove the small amount of the dustin the fridge on the internal and external and accessories with dry cloth. If the fridge is too dirty, use neutral detergent and wash thoroughly with clean water after washing. Do not rinse the inside and upside of the refrigerator with water, otherwise, it will damage the insulation and cause failure.
7. Don’t put the lubricating oil to the compressor and other mechanical parts.
8. Take care when cleaning the fans in the back of the compressor.
9. The maintenance and maintenance of cryogenic refrigerator is particularly important to extend the life and the normal use. If the temperature control is not accurate, it often leads to damage the saved objects which will cause great influence to the experimental results, thus affecting the normal work.
Recomendações relacionadas
-
Lneya Semiconductor Refrigeration Heating Circulation Wind System Test Description
1147There are many test items in the refrigeration and heating circulating air system for semiconductors. So, how much do users know about the out-of-channel testing of the semiconductor refrigeration and heating circulating air system? The out-of-cha...
Ver pormenores -
LNEYA hot and cold machine SUNDI manual
1409The temperature range of the hot and cold machine ranges from -120 ° C to 350 ° C. It has superior performance and unique performance. It has high precision and intelligent temperature control. The high cooling power is from 0.5 to 1200 kW. High p...
Ver pormenores -
Characteristic Analysis of Air Cooled Industrial Chiller
898Industrial air-cooled chillers are generally integral machines, that is, evaporator, compressor and condenser are made together. For a slightly high-power air-cooled industrial chiller, the heat dissipation of the condenser cooling fan needs to be...
Ver pormenores -
What are the characteristics of the pressure of industrial water chillers
1127Industrial water chillers are one of themost popular equipment in the machinery and equipment industry. For thisreason, the editor of LNEYA specially compiled relevant pressure instructionsto help everyone better understand industrial water chi...
Ver pormenores