LNEYA tratamento do choro super profundo com bom senso
For ultra-deep cold processing equipment, failure to pay attention to the use of the equipment may cause equipment failure.
Before using the water-cooled ultra-cry cryogenic treatment, it should be checked whether all the valves between the equipments are open, whether all the water tanks are filled with water, whether the fans are reversed, and whether the circulating water pump is running in the correct direction. Open the super deep crying treatment main power supply (the standard power supply is 3-phase five-wire system 380V 50HZ), specifically the water-cooled ultra-deep cold treatment front nameplate. Wuxi Guanya LNEYA reminds everyone that the power supply for ultra-deep cooling must be stable to avoid burning the unit or compressor and pump motor.
First open the ultra-deep cooling treatment cooling switch, then turn on the chilled water pump switch. Since the compressor has a delayed start function, the compressor will automatically run after the delay. At this time, pay close attention to the front control panel to observe the temperature change, as appropriate according to the cooling demand. Perform temperature adjustment. Water-cooled ultra-cry cryogenic treatment During normal operation, the unit operation data should be recorded periodically to facilitate the identification of problems based on data as soon as the unit fails. The ultra-cryogenic treatment itself is provided with multiple protection devices. Once there is a fault, it will start to protect and automatically stop. After the fault is removed, press the reset to operate normally.
When the super-cryogenic treatment is not used, the unit, water pump, insulated water tank and water in the pipeline should be drained, and the equipment should be covered and protected to avoid dust and other debris. Regarding the maintenance of ultra-deep cold treatment, this cannot be ignored. It is necessary to clean the condenser and evaporator after running for half a year. It is recommended to carry out maintenance of the whole machine after one year of operation, and keep it clean and clean regularly.
The instruction manual of the ultra-cryogenic treatment equipment and regular inspection and maintenance are all parts that the user needs to know in order to make the equipment run more efficiently.

Recomendações relacionadas
-
Com estes pontos, a eficiência de utilização do refrigerador de temperatura ultrabaixa pode ser mais eficiente
1049A estrutura do refrigerador de temperatura ultra baixa é mais complicada. A sua principal função é fornecer ar frio ao produto, que é a função de refrigeração. Se quisermos melhorar a eficiência do congelador, devemos prestar atenção à ...
Ver pormenores -
Why do constant temperature and humidity chamber need water cooling units?
863Constant temperature and humidity chamber need water cooling units mainly for the following key reasons: Accurate temperature and humidity control: Water cooling units can provide efficient and accurate temperature regulation capabilit...
Ver pormenores -
O que causa sedimentos na utilização do refrigerador?
877A chiller is a water-cooled unit that uses water circulation to provide a constant temperature, constant flow and constant pressure cooling water. The LNEYA cold water system has its own working principle, that is, a certain amount of water is inj...
Ver pormenores -
Sistema de ensaio global de motores de automóveis de energia nova
1118Quando o sistema de ensaio integrado do motor do veículo de energia nova LNEYA está a funcionar, são necessárias as definições do painel de controlo. No momento da regulação, se o utilizador não souber como o utilizar, pode consultar o manual de utilização. O indicador da nova energia ...
Ver pormenores