Why do constant temperature and humidity chamber need water cooling units?
Constant temperature and humidity chamber need water cooling units mainly for the following key reasons:
Accurate temperature and humidity control: Water cooling units can provide efficient and accurate temperature regulation capabilities, which is essential for maintaining strict temperature and humidity conditions in constant temperature and humidity chamber. For example, when storing medicines, precision electronic components, artworks, special materials and other items with extremely high environmental requirements, it is necessary to control the temperature and humidity within a very precise range to ensure the quality and stability of the items.
High energy efficiency and energy saving: Compared with traditional air cooling systems, water cooling systems usually provide higher energy efficiency ratios, especially in large constant temperature and humidity warehouses that require a lot of refrigeration. The heat capacity of water is greater than that of air, so it can absorb and transfer heat more effectively, reduce energy consumption, and reduce operating costs.
Low noise and environmental protection: Compared with air cooling systems, water cooling systems have lower noise during operation, which is especially suitable for application scenarios that require a quiet environment. At the same time, water cooling units using environmentally friendly refrigerants have less impact on the environment, which is in line with the modern industrial trend of green energy saving.
Stability and continuous operation: The water cooling system has higher stability in continuous operation and is suitable for constant temperature and humidity warehouses that need to maintain a constant temperature and humidity environment for a long time. The temperature regulation of circulating water is more stable than air, and is not easily affected by changes in external temperature, which ensures the constancy of the environment in the warehouse.
Space utilization and flexibility: The outdoor part of the water cooling unit (such as the cooling tower) can be far away from the main body of the warehouse, reducing the occupation of the internal space of the warehouse, while providing greater system design flexibility. This is especially important for constant temperature and humidity warehouses with limited space or special layout requirements.
Easy maintenance and long life: Although the initial installation cost may be high, the maintenance of the water cooling system is relatively simple and the equipment life is long. Through regular water quality treatment and maintenance, the service life of the water cooling system can be effectively extended and the long-term operating cost can be reduced.
In summary, the water cooling unit has become an ideal choice for meeting the high-standard environmental requirements of constant temperature and humidity chamber with its precise temperature and humidity control capabilities, high energy efficiency, low noise, strong stability, and flexible space layout.
LC-WS -25℃~5℃
1.The standard design conditions are: chilled water:outlet water temperature 7 ° C, return water temperature 12 ° C; condensing temperature 40 ° C.2.Due to continuous updating of product technology, the above data …
LC-ZS -25℃~5℃
* 1.The standard design conditions are: chilled water:outlet water temperature 7 ° C, return water temperature 12 ° C; condensing temperature 40 ° C.2.Due to continuous updating of product technology, the above …
FL-WS 5℃~30℃
1.The standard design conditions are: chilled water:outlet water temperature 7 ° C, return water temperature 12 ° C; condensing temperature 40 ° C.2.Due to continuous updating of product technology, the above data is su…
FL-WD 5℃~30℃
* 1.The standard design conditions are: chilled water:outlet water temperature 7 ° C, return water temperature 12 ° C; condensing temperature 40 ° C.2.Due to continuous updating of product technology, the above data is …
carregando...
已经是到最后一篇内容了!
Recomendações relacionadas
-
Descrição da seleção do refrigerador criogénico arrefecido a ar
1218Many users struggle with the problems of air-cooled cryogenic chillers and water cooled cryogenic chillers. However, enterprises should make choices according to their actual environment. For this reason, Wuxi Guanya professional manufacturer has ...
Ver pormenores -
The Noise Analysis of Precision Chiller
1294Generally speaking, even the most sophisticated refrigerating equipment will also have some trouble when used for a long time. If the noises present in the precision chiller after prolonged use, I am sure that it appears some faults. So let's go d...
Ver pormenores -
Effect of cooling and heating temperature cycle during emulsification
1552Emulsification is the effect of a liquid in which even tiny droplets are evenly dispersed in another liquid that is incompatible with each other. Emulsification is a liquid-liquid interface phenomenon. Two immiscible liquids, such as oil and water...
Ver pormenores -
Failures of Heating Cooling Circulators
951The heating cooling circulator can be used in many chemical pharmaceuticals and laboratories. Then, how to solve the failures of the heating cooling circulator?Failure of circulating pumpThe failure of the circulating pump is generally the heat ov...
Ver pormenores