Semiconductor laser automatic temperature control equipment accessories fault solution
Semiconductor laser automatic temperature control compressor frosting, may be circulating water circulation or valve is not open, check the water valve, all pipelines, to ensure smooth, install short-circuit pipeline. It may be that the circulating water pipe is too small, and the diameter of the circulating water pipe is increased to ensure the normal water circulation.
Semiconductor laser automatic temperature control icing in the circulating water tank may be set too low to correct the set value; there may be no circulating water in the water tank, short circuit water circulation between the chilled water outlet and the inlet; may be the temperature control table out of control Replace the temperature control table with high-voltage faults, poor heat dissipation, the radiator is too dirty, the cleaning radiator can be bad, improve the ventilation conditions, the cooling fan does not work, check whether the fan motor burns out, short-circuit repair or replace the motor; high-pressure engine damage, replacement of high voltage Bad; poor cooling, insufficient refrigerant or pipeline leakage, replenishing refrigerant or repairing after leak detection, vacuuming and replenishing refrigerant, poor heat dissipation, radiator is too dirty, the radiator valve is not opened or opened too small, the radiator is cleaned, Open the valve fully.
Semiconductor laser automatic temperature control pump failure may be semiconductor laser automatic temperature control pump motor coil short, open circuit, repair motor coil or replace the motor, if the pump overload protector automatically jumps, the current limit of the protector is within the allowable range Press the reset button halfway as appropriate.
Semiconductor laser automatic temperature control temperature according to the table temperature display digital up and down jump may be the temperature control table damage, repair or replace the temperature control table, may be poor temperature line contact, repair or replace the temperature line, may be the temperature line and temperature measurement The body is dirty and the temperature measuring body is wiped clean.
The semiconductor laser automatic temperature control compressor failure may be that the compressor coil is short, open circuit, replace the matching compressor, the compressor overload protector automatically trips, and the current limit of the protector is appropriately adjusted and pressed within the allowable range. Reset button.
In order to avoid some faults in the accessories of the semiconductor laser automatic temperature control, it is recommended to maintain a lot of instructions on the automatic temperature control of the semiconductor laser and do the maintenance work.
Recomendações relacionadas
-
Teoria do fluxo de gelo, qualidade da água gelada, fluxo e pressão da máquina de água gelada
1328O amaciamento da água é também um problema importante no processo de utilização de refrigeradores, sendo necessário observar continuamente o valor do pH da água. O valor ótimo de pH deve ser igual a 7. Um valor de pH superior a 7 provoca uma corrosão terrível...
Ver detalhes -
The benefits of choosing a cryostat
2190The temperature of the effluent of the cryogenic refrigerator is very low, so the carrier medium can not be used for water (the water will freeze when it reaches 0 ° C). At this time, it is necessary to use a brine solution or a glycol solution, a...
Ver detalhes -
Cooling heating temperature control system SUNDI series thermal fluid filling instructions
19231. Refrigeration heating temperature control system SUNDI series equipment before the heat conduction filling, the heat transfer liquid inlet of the heating refrigeration circulator and the heat transfer liquid outlet of the upper end of the react...
Ver detalhes -
Novo método de ensaio energético e caso de aplicação do termóstato de simulação de temperatura
1478LNEYA bateria de veículo de energia nova teste de ciclo de alta e baixa temperatura é um dos equipamentos mais utilizados em testes de bateria de veículos modernos. A bateria de lítio é uma das baterias mais comuns. A que é que se deve prestar atenção quando a utilizamos? ...
Ver detalhes
LNEYA Refrigeradores industriais Fabricante Fornecedor