Novo método de ensaio energético e caso de aplicação do termóstato de simulação de temperatura
LNEYA bateria de veículo de energia nova teste de ciclo de alta e baixa temperatura é um dos equipamentos mais utilizados em testes de bateria de veículos modernos. A bateria de lítio é uma das baterias mais comuns. A que é que se deve prestar atenção quando a utilizamos? ...
Application introduction:
The temperature simulation thermostat system is also called high and low temperature cooling test machine/new energy test thermostat. It consists of a refrigeration compressor unit, a cold storage box, a heat exchange container, a circulating pump unit, and a control device. It is often used for electric drive, motor testing, and battery pack testing of new energy vehicles.
Instructions:
The use of lithium batteries needs to grasp the time, prevent overcharging, and do the right thing at the right time. Although the lithium battery itself has excellent electrochemical performance, however, any kind of thing will have potential safety hazards when it deviates from the equilibrium state.
It is recommended to maintain the lithium battery at a suitable temperature and prevent cold and heat. When idle, lithium batteries usually do not have safety accidents. The purpose of daily maintenance is to place lithium batteries in a suitable environment, thereby delaying the aging of batteries. In fact, one of the parameters of the lithium battery is the appropriate temperature. Relatively speaking, it is not a big problem if the temperature is lower, but if it is placed at a higher temperature, as the saying goes, the extreme will reverse, and it will also cause safety problems. We are talking about idle state only in terms of normal environment
Temperature simulation thermostat maintenance method:
If the lithium battery is placed in water or close to a fire, it is already out of the topic of “maintenance”. Then, what should be done in a normal environment? The water side protects against moisture and the hot side protects against sun exposure. Therefore, in the correct use of lithium batteries, the charging method of lithium batteries is more important, because incorrect charging methods will cause safety problems, and discharge and daily maintenance only affect the service life of lithium batteries. The battery itself is also a consumable. No matter what we do, we can’t avoid its subsequent wear and tear. It’s just that we use the correct method to delay its aging.
Features of new energy application case of temperature simulation thermostat
A suitable proportion of water and ethylene glycol mixture is used as the cooling medium, the temperature adjustment range is -40℃~85℃, and the temperature control accuracy can reach ±0.5℃. The temperature conversion rate is 4 ℃/min, and the Siemens PLC controller is used as the temperature controller, and the temperature control can be freely edited with time.
Flow adjustment range: 2 ~ 30L/min. Flow control accuracy: ±0.2L/min. Pressure adjustment range: 0 ~ 400kpa, pressure control accuracy: ±5kpa. The high and low temperature cooling and heating integrated machine system adopts PLC programming control, and the whole system adopts CAN communication or RS485 communication to link with the upper computer to realize remote control. Realize local and remote manual and automatic temperature control. Remotely set the temperature value, temperature conversion rate and flow value, and run according to the set curve programming. At the same time, it can read the temperature value, flow value and pressure value in real time, and data collection and output functions such as temperature, pressure and flow.
LNEYA provides temperature simulation thermostat customization for electric drive, motor testing and battery pack testing of new energy vehicles. Customized cooling and heating thermostats are available.
Recomendações relacionadas
-
As vantagens do chiller arrefecido a água que precisa de conhecer
1123Industrialchillers can be generally divided into water-cooled and air-cooled according tothe type of refrigeration. The heat exchange medium of Water Cooled Chillers iswater.LNEYA has designed and developed a new type of temperature controlequ...
Ver pormenores -
Factores que afectam a capacidade de arrefecimento do refrigerador do sistema de arrefecimento do reator químico
1356There are various types of chillers, such as air-cooled chillers, water-cooled chillers, etc. But no matter what the chiller is, there are some factors that affect the cooling capacity of the chiller. A cooler is an energy-saving device that is co...
Ver pormenores -
Porque é que existe o fenómeno de congelamento no circulador do refrigerador de baixa temperatura?
1081Muitos circuladores de refrigeradores de baixa temperatura congelam quando são usados, mas não há fenómeno de congelamento nos circuladores de refrigeradores de baixa temperatura. Então, qual é o problema? Está relacionado com a refrigeração? Em primeiro lugar, porque é que o circulador de refrigeração de baixa temperatura...
Ver pormenores -
Como escolher o circulador quente e frio certo?
1039The hot and cold circulator is widely used in the pharmaceutical and chemical industry to provide users with hot and cold controlled, uniform temperature and constant temperature. It can also be directly equipped with reactors, reactors, etc. fo...
Ver pormenores