Como eliminar a falha de uma câmara de ensaio de choque térmico de grandes dimensões?
Como a tecnologia continua a avançar e a melhorar, a LNEYA recomenda requisitos rigorosos para os operadores de grandes câmaras de ensaio de choque térmico. Em caso de utilização incorrecta, os operadores devem ser capazes de enfrentar e resolver estes problemas em tempo útil. Um grande t...
A large thermal shock test chamber can be formed by the tank, the air circulation system, the refrigeration system and the heating system. When the high and low temperature experiments are carried out, the temperature rise is very slow, and the wind circulation system may not be normally opened, and the temperature change If the experimental temperature is not reached, it is necessary to solve the problem according to different states.
If the large-scale thermal shock test chamber does not reach the temperature change of the test index at low temperature, it may be that the temperature will always be very slow, or it may rise after the temperature reaches a certain value. When the above 2 cases occur, It is necessary to check whether the test chamber is in a dry environment before the low temperature test. After the test chamber is kept in a dry environment, the test sample can be placed indoors for testing. Another reason is whether the sample is placed too much, so that the air circulation in the room circulates. If this is not the case, the operator should contact the manufacturer for professional repairs.
There is another factor that may cause the failure, that is, the temperature control of the large thermal shock test chamber is not good, and the temperature in the laboratory where the equipment is placed is an environment with an average temperature of 25 ° C in 24 hours, and the humidity is about ≤ 85%. RH is fine. Even the best equipment needs a good place to be placed, and the large thermal shock test chamber is no exception. In order to ensure that the equipment can reach the temperature during the test and the life is extended, every operator should maintain it.
If the large-scale thermal shock test box fails, the operator needs to perform professional fault resolution to make the test box run smoothly.
Recomendações relacionadas
-
Impact and Solution of Excess Exhaust Temperature of Industrial Chiller Units
1724Industrial water chiller compressor exhaust temperature determines whether the equipment can stably and efficiently run. The common problem of compressor is excess exhaust temperature. Once the situation appears, it is easy to make industrial chil...
Ver detalhes -
Como escolher o equipamento de ensaio de envelhecimento a baixa temperatura e a alta temperatura?
1798A capacidade de refrigeração e a gama de temperaturas dos materiais em diferentes indústrias são diferentes. De um modo geral, a capacidade de refrigeração divide-se em 80kw, 120kw, 180kw, 240kw, 360kw, e a temperatura de refrigeração varia entre -25°C e -5°C. ...
Ver detalhes -
Análise de peças do refrigerador de baixa temperatura
1862O refrigerador de baixa temperatura é um equipamento de arrefecimento de água que é amplamente utilizado. Assim, ao usá-lo, você deve primeiro entender o princípio do resfriador de água criogênica e seus acessórios, de modo a executar o resfriador de água criogênica mais eficiente...
Ver detalhes -
Quais são as medidas de manutenção dos refrigeradores de glicol em funcionamento diário?
1771No funcionamento diário do refrigerador de glicol, se a manutenção não for efectuada, o efeito de arrefecimento será reduzido. Por isso, para melhorar a eficiência de funcionamento, recomendamos que efectue a manutenção diária necessária. Refrigerador...
Ver detalhes
LNEYA Refrigeradores industriais Fabricante Fornecedor