Instruções de carregamento do refrigerante do congelador com grandes diferenças de temperatura
In the development of modern industry, large temperature difference freezer is also important in cold treatment. In the whole process of large temperature difference freezer refrigeration, refrigerant charging is also more important. So how do you charge?
For large-temperature-difference freezer refrigeration systems without high-pressure reservoirs and low-pressure vapor-liquid separators, the control of refrigerant charge is particularly important. Because the refrigeration system is a condenser and also acts as a high-pressure reservoir, the refrigerant is stored in the condenser, and the condenser is cooled. The heat dissipation area is reduced and the condensing pressure is increased, resulting in a decrease in cooling capacity.
For the control of the refrigerant charge of such a large temperature difference freezer, during the charging process, the temperature of the condenser casing should be touched, the upper outlet of the condenser outlet is heated, and the outlet below the outlet is cool (heating) It is indicated that there is a high-temperature exhaust gas of the compressor condensing inside, and the cooling is cold, indicating that the water-cooled large temperature difference refrigerator is a liquid space). Secondly, look at the suction pressure, which corresponds to the temperature of the refrigerant water in the evaporator (that is, corresponds to the evaporation temperature). Then, depending on the return temperature of the compressor of the large temperature difference refrigerator, the return pipe of the high temperature unit should be cooled and dew, but it can be dew condensation to the compressor return valve. The return pipe of the low temperature unit should be frosted, but the frost is compressed. The machine return valve is fine. If condensation or frost builds up on the compressor casing, liquid refrigerant will enter the crankcase, causing the compressor to run oil and liquid. For hermetic compressors, the motor terminals are also shorted. Although most of the closed unit terminals are sealed with a sealant, the possibility of a short circuit still exists due to the uncertainty of the sealing effect.
The above is the refrigerant charging method of Wuxi Guanya LNEYA finishing, hope to help everyone to run a large temperature difference freezer.

Recomendações relacionadas
-
Descrição do disparo do frigorífico de alta potência
904O frigorífico de alta potência Wuxi Guanya LNEYA está equipado com acessórios de marca. O desempenho de refrigeração de todo o frigorífico de alta potência é relativamente estável. Uma vez que a viagem de energia ocorre, ele precisa ser processado no tempo para evitar afetar a operação.
Ver pormenores -
Descrição do desvio de temperatura do sistema de aquecimento de ciclo fechado
899Se ocorrer um desvio de temperatura no sistema de aquecimento de ciclo fechado durante a utilização, é necessário verificar se existe algum problema em cada ligação e resolver o problema a tempo. No estado estacionário, o sistema de aquecimento de ciclo fechado apresenta a...
Ver pormenores -
Encontro no Pavilhão da Exposição Mundial de Xangai 【Exposição de Pesticidas】Booth 1G10 10.12-10.14
1275Nome da exposição: 20ª Conferência Nacional de Intercâmbio de Pesticidas e Salão de Exposições de Produtos AgroquímicosTempo de exposição: 12-14 de outubro de 2020Número do stand: 1G10Endereço da exposição: Shanghai World Expo Exhibition Hall ,
Ver pormenores -
Instruções de cablagem da bobina do ventilador do congelador industrial de baixa temperatura
1095The electric two-way valve red line of the low-temperature industrial freezer is 220V hot wire (L) directly connected to the thermostat fire line interface, the blue line is zero line (N), the coil, the two-way valve, the thermostat is connected i...
Ver pormenores