X-ray diffraction (XRD) systems are widely used in materials science, chemistry, physics and other fields to study the crystal structure of substances. In order to conduct experiments under different temperature conditions, a heating and cooling circulator that can provide precise temperature control is usually required. This equipment can ensure that the sample remains stable within the required temperature range, so as to obtain accurate diffraction data.
Main features
- Ampla gama de temperaturas:
- Temperature range: -25°C to 200°C
- Such a temperature range can cover a variety of experimental needs from low temperature to high temperature.
- Controlo de temperatura de alta precisão:
- The control accuracy is usually ±0.1°C or less to ensure high consistency of experimental conditions.
- Use PID controller or other advanced temperature control technology to achieve fast and stable temperature adjustment.
- Fast heating and cooling capabilities:
- Fast heating: Able to heat the sample to the set temperature in a short time.
- Fast cooling: Through an efficient refrigeration system, the sample is quickly cooled to the required temperature.
- Helps improve experimental efficiency, especially when temperature conditions need to be changed frequently.
- Bomba de circulação:
- The built-in circulation pump circulates the cooling medium (usually thermal oil or water/ethylene glycol solution) between the heating/cooling unit and the sample chamber to ensure uniform temperature distribution.
- The flow rate of the circulation pump should match the sample chamber of the XRD system, usually between a few liters per minute and tens of liters per minute.
- Safety protection measures:
•Over-temperature protection: Automatically cut off the power supply when the temperature exceeds the set value.
•Over-pressure protection: Prevent the system pressure from being too high.
•Leak detection: Detect whether the system has leaks.
•Emergency stop button: Quickly stop the system operation in an emergency.
- Operation interface:
Ecrã tátil ou digital: Apresenta intuitivamente a temperatura atual, a temperatura definida e outros parâmetros.
Interface de funcionamento de fácil utilização: Fácil de definir e monitorizar a temperatura, suporta funções de programação e registo de dados.
- Compatibility:
•Compatible with the sample chamber interface of the XRD system to ensure seamless integration.
•Specific connectors or adapters may be required to connect the circulator and the sample chamber.
Application field
- Ciência dos materiais:
•Study the changes of crystal structure of materials at different temperatures, such as phase change, thermal expansion, etc.
•Evaluate the performance of new materials under high or low temperature conditions.
- Chemistry:
•Study the crystal structure of compounds at different temperatures to understand their thermal stability.
•Explore the changes of crystal structure during reaction.
- Chemistry:
•Study the crystal structure of compounds at different temperatures to understand their thermal stability.
•Explore the changes of crystal structure during reaction.
- Physics:
•Study the change of solid physical properties with temperature, such as magnetism, conductivity, etc.
•Explore the behavior of new materials under extreme temperature conditions.
- Geology:
•Study the crystal structure of minerals at different temperatures and understand the physical processes inside the earth. Summary Heating and cooling circulators for X-ray diffraction systems are important auxiliary equipment that can provide a wide temperature range (-25°C to 200°C), high-precision temperature control, and fast heating and cooling capabilities. This equipment is essential for accurate XRD analysis under different temperature conditions.
When choosing a heating and cooling circulator, the following factors should be considered:
- Temperature range: Make sure the system can cover the required temperature range.
- Temperature control accuracy: Choose a system with high-precision temperature control, such as a PID controller.
- Heating and cooling capacity: Choose heating and cooling power that suits the experimental needs.
- Safety: Make sure the system has multiple safety protection measures to ensure the safety of operators and equipment.
- Compatibility: Make sure the circulator is compatible with the sample chamber interface of the XRD system.
It is recommended to consult a professional equipment supplier or engineer before purchasing to ensure that you choose the heating and cooling circulator that best suits your needs.
Sistemas dinâmicos de controlo da temperatura -120℃~350℃
Série de Conversão de Frequência SUNDI Z
WHATSAPP WECHAT A tecnologia de resfriamento de temperatura ultra-alta pode resfriar diretamente de uma alta temperatura de 300 ℃ [porque apenas o meio de transferência de calor na expansão...
SUNDI -10℃~150℃
Sistema totalmente fechado, único meio completa refrigeração e aquecimento -120 ~ 350 ℃ ± 0,5 ℃ AC 380V 50HZ 8kW max A tecnologia de resfriamento de temperatura ultra-alta pode resfriar diretamente de um ...
SUNDI -80℃~250℃
● Temperaturas de trabalho de -120°C a +350°C ● Desempenho anteriormente inalcançável ● Controlo inteligente da temperatura ● Máxima estabilidade e reprodutibilidade do processo ● Permutador de calor de placas Adop, aquecimento por condutas, o aquecimento mais rápido ...
SUNDI-320/320W
Sistema totalmente fechado, meio único completa refrigeração e aquecimento -120 ~ 350 ℃ ± 0.5 ℃ Tecnologia de resfriamento de temperatura ultra-alta pode resfriar diretamente de 300 ℃ de alta temperatura. Bec...
SUNDI -25℃~200℃
Sistema totalmente fechado, um único meio completa a refrigeração e o aquecimento -120~350℃ ±0,5℃ ● Temperaturas de trabalho de -120°C a +350°C ● Desempenho anteriormente inatingível ● Controlo inteligente da temperatura...
SUNDI -45℃~250℃
● Temperaturas de trabalho de -120°C a +350°C ● Desempenho anteriormente inalcançável ● Controlo inteligente da temperatura ● Máxima estabilidade e reprodutibilidade do processo ● Permutador de calor de placas Adop, aquecimento por condutas, o calor mais rápido...
SUNDI -60℃~250℃
A tecnologia de resfriamento de temperatura ultra-alta pode resfriar diretamente de uma alta temperatura de 300 ℃ [porque apenas o meio de transferência de calor na câmara de expansão entra em contato com o óxido...
SUNDI -80℃~250℃
Temperaturas de trabalho de -120°C a +350°C● Desempenho anteriormente inalcançável● Controlo inteligente da temperatura● Máxima estabilidade e reprodutibilidade do processo● Permutador de calor de placas de adoção, aquecimento por conduta, o aquecimento mais rápido...
SUNDI -90℃~250℃
● Temperaturas de trabalho de -120°C a +350°C ● Desempenho anteriormente inalcançável ● Controlo inteligente da temperatura ● Máxima estabilidade e reprodutibilidade do processo ● Permutador de calor de placas Adop, aquecimento por condutas, o calor mais rápido...
SUNDI -100℃~100℃
● Temperaturas de trabalho de -120°C a +350°C ● Desempenho anteriormente inalcançável ● Controlo inteligente da temperatura ● Máxima estabilidade e reprodutibilidade do processo ● Permutador de calor de placas Adop, aquecimento por condutas, o calor mais rápido...
carregando...
已经是到最后一篇内容了!
Consult other instrument temperature control units

WeChat 86 15152266993

WhatsApp 86 13912479193
Recomendações relacionadas
-
UST series
2456It is suitable for the needs of various process production and experimental use in pharmaceutical and chemical enterprises. It can realize high temperature cooling process, directly cooling from high temperature of 300 degrees t...
Ver pormenores -
Teste de semicondutores Unidade de circulação de aquecimento de duplo canal
342O ciclador de aquecimento de canal duplo em ensaios de semicondutores refere-se a um dispositivo utilizado para ensaiar dispositivos semicondutores (como semicondutores de potência), que pode controlar simultaneamente dois canais de ensaio independentes para efetuar o aquecimento e o arrefecimento...
Ver pormenores -
HRT -45℃~250℃
1437O refrigerador é uma parte muito importante do compressor de ar de parafuso. A principal função é arrefecer o óleo lubrificante do compressor de ar e o ar comprimido. Se estiver bloqueado, a temperatura aumentará. Uma das principais causas de t...
Ver pormenores -
HR -25℃~200℃
1478O refrigerador é uma parte muito importante do compressor de ar de parafuso. A principal função é arrefecer o óleo lubrificante do compressor de ar e o ar comprimido. Se estiver bloqueado, a temperatura aumentará. A...
Ver pormenores