Detalhes do dispositivo de proteção do dispositivo de controlo da temperatura do fluido de circulação
The circulating pump overload protection function is to cut off the main power of the circulating pump when the circulating liquid temperature adjustment device is too large. Press the green button when resetting; the red button is the stop button, which is used during the test. When frequent protection, please check whether the voltage is under voltage (undervoltage is less than 15%, the power protector is not working), undervoltage is increased into current, forming protection. At this time, a Phillips screwdriver can be used to adjust according to the “△” direction. Current.
Different circulating fluid temperature adjustment devices are equipped with different high and low voltage protectors. The high and low pressure protectors will protect the compressor with reference to the suction and exhaust pressure of the compressor to ensure the normal operation and operating life of the compressor. The high and low voltage protectors are divided into mechanical and electronic high and low voltage protectors. When the high and low voltage protectors are protected, manual reset is required. Press the red highlight button to reset. When the high and low voltage protectors generate protection, manual reset is required. Push the red arrow to reset. The electronic high and low voltage protector is automatically reset.
The circulating fluid temperature adjustment system provides a lot of accessories for equipment protection to ensure the safety and stability of the equipment. The over temperature protection has an independent high temperature temperature limit switch, which can set a relatively large temperature value through this temperature switch (please note) Meet the relatively large operating temperature range of the equipment and the temperature range of the heat transfer oil).
Inspiratory temperature protection with independent compressor suction temperature protector to protect the compressor from excessive suction temperature, ensure that it is within 65 °C (non-recycling liquid temperature adjustment device manufacturer authorization, do not modify, will directly affect the compressor Cooling capacity).
Circulating fluid temperature adjustment device The oil pressure difference protector is generally applied in large equipment. Depending on the equipment, the oil pressure difference protector is different. Press the upper ink green button when resetting. Other types of oil pressure difference protectors are similar. The reset button can be reset by itself. Other protections of the circulating fluid temperature adjustment device include phase protection, phase loss protection, overvoltage and undervoltage protection, leakage protection, and water shutoff protection.
The protection devices of different circulating liquid temperature adjustment devices are different. No matter what brand, the safety devices are more important. We need to pay attention to them. We must carefully check before purchasing to ensure the operation of the equipment.
Recomendações relacionadas
-
A que é que deve prestar atenção ao instalar um sistema de arrefecimento de uma pilha de carga DC?
1296Antes de instalar um sistema de arrefecimento de pilha de carga DC, é necessário compreender as caraterísticas do equipamento. Isto inclui coisas como o tamanho do dispositivo, o peso, a gama de temperaturas de funcionamento e os requisitos de energia. Certifique-se de que o equipamento...
Ver detalhes -
Função do evaporador no chiller arrefecido a ar
1589O chiller arrefecido a ar adopta o modo de arrefecimento a ar, que elimina a torre de arrefecimento essencial, a bomba de água de arrefecimento e o sistema de tubagem do sistema de água de arrefecimento, evita a incrustação do condensador e o bloqueio da tubagem de água em áreas com pouca qua...
Ver detalhes -
Princípio de funcionamento e processo do controlador de pressão e controlo de temperatura do refrigerador
2583O controlador de temperatura do chiller refrigerado a ar é um regulador de duas posições, também conhecido como relé de controle de temperatura do chiller. De acordo com a mudança de temperatura ajustada, o controle de temperatura do chiller faz o contato ligado ou desligado, controlando assim ...
Ver detalhes -
Why choose LNEYA’s reactor automatic temperature control equipment?
2070With the rapid development of pharmaceutical and chemical industry, the market demand for automatic temperature control equipment for reactors is expanding. The requirements for automatic temperature control equipment for reactors are also rising,...
Ver detalhes
LNEYA Refrigeradores industriais Fabricante Fornecedor