Detalhes do dispositivo de proteção do dispositivo de controlo da temperatura do fluido de circulação
The circulating pump overload protection function is to cut off the main power of the circulating pump when the circulating liquid temperature adjustment device is too large. Press the green button when resetting; the red button is the stop button, which is used during the test. When frequent protection, please check whether the voltage is under voltage (undervoltage is less than 15%, the power protector is not working), undervoltage is increased into current, forming protection. At this time, a Phillips screwdriver can be used to adjust according to the “△” direction. Current.
Different circulating fluid temperature adjustment devices are equipped with different high and low voltage protectors. The high and low pressure protectors will protect the compressor with reference to the suction and exhaust pressure of the compressor to ensure the normal operation and operating life of the compressor. The high and low voltage protectors are divided into mechanical and electronic high and low voltage protectors. When the high and low voltage protectors are protected, manual reset is required. Press the red highlight button to reset. When the high and low voltage protectors generate protection, manual reset is required. Push the red arrow to reset. The electronic high and low voltage protector is automatically reset.

The circulating fluid temperature adjustment system provides a lot of accessories for equipment protection to ensure the safety and stability of the equipment. The over temperature protection has an independent high temperature temperature limit switch, which can set a relatively large temperature value through this temperature switch (please note) Meet the relatively large operating temperature range of the equipment and the temperature range of the heat transfer oil).
Inspiratory temperature protection with independent compressor suction temperature protector to protect the compressor from excessive suction temperature, ensure that it is within 65 °C (non-recycling liquid temperature adjustment device manufacturer authorization, do not modify, will directly affect the compressor Cooling capacity).
Circulating fluid temperature adjustment device The oil pressure difference protector is generally applied in large equipment. Depending on the equipment, the oil pressure difference protector is different. Press the upper ink green button when resetting. Other types of oil pressure difference protectors are similar. The reset button can be reset by itself. Other protections of the circulating fluid temperature adjustment device include phase protection, phase loss protection, overvoltage and undervoltage protection, leakage protection, and water shutoff protection.
The protection devices of different circulating liquid temperature adjustment devices are different. No matter what brand, the safety devices are more important. We need to pay attention to them. We must carefully check before purchasing to ensure the operation of the equipment.
Recomendações relacionadas
-
Introdução à utilização de um refrigerador de precisão à prova de explosão
1126Wuxi Lneya resolve o problema do carregamento de refrigerantes na ausência de refrigeração. 1. Ligar bem todo o tipo de equipamento, fechar as três válvulas quando a pressão de vácuo desce para 133,3Pa, retirar a mangueira da porta de sucção da válvula de vácuo...
Ver pormenores -
Conquistou o segundo lugar na edição de 2022
1532Em 18 de novembro de 2022, foi patrocinada pela Associação Provincial de Ciência e Tecnologia de Jiangsu, pelo Gabinete Provincial para os Assuntos de Taiwan, pelo Departamento Provincial da Indústria e Tecnologia da Informação, pelo Departamento Provincial da Agricultura e pelo Departamento Provincial de...
Ver pormenores -
Como limpar o sistema de controlo do ar?
1318In order to respond to the requirements of the two types of society in the country, environmental protection and conservation have become increasingly important. Therefore, in order to extend the life of the product, it is still necessary to have ...
Ver pormenores -
Como resolver a condensação do teste do motor do veículo elétrico é demasiado elevada?
1088A pressão de condensação do ensaio do motor do veículo elétrico aumentará, a função de compressão aumentará, a capacidade de arrefecimento diminuirá, o coeficiente de arrefecimento diminuirá e o consumo de energia aumentará. A razão para t...
Ver pormenores