Função do evaporador no chiller arrefecido a ar
The air-cooled chiller adopts the air cooling mode, which eliminates the essential cooling tower, cooling water pump and pipeline system of the cooling water system, avoids the condenser scaling and water pipe blockage in areas with poor water quality, and saves water resources. It is the most economical and simple machine for maintenance and repair in the current refrigeration equipment. The one-time investment of air-cooled chiller is slightly higher than that of water-cooled chiller, but the annual operation cost is lower than that of water-cooled chiller. The construction cost of machine room is the least among various cold and heat source systems, and the maintenance cost is about half of that of water-cooled chiller.
When the temperature of air or other fluid decreases, the pressure in the temperature sensing bag decreases. The valve port of the temperature control pilot valve is closed, and the refrigerant gas flow from the evaporator to the main regulating valve decreases. When the pressure at the top of the main piston is discharged into the suction pipe of the compressor, the main spring closes the main valve. In the air-cooled chiller system, when the evaporator pressure regulating valve is used to control the temperature, the temperature control pilot valve should be used to replace the pressure control pilot valve introduced earlier, so that the temperature of air or other fluids flowing through the evaporator can be accurately maintained at a predetermined value.
The evaporator is one of the four major components in the chiller system. The evaporator plays a role in heat dissipation in the chiller system. Connect the temperature control pilot valve with the joint of the outer pressure guide hole of the evaporator pressure regulating valve, and place the temperature sensing package of the pilot valve in the air flow or flowing medium to control its temperature. When the temperature of air or other medium increases, the pressure in the temperature sensing package increases, and the valve port of the temperature control pilot valve opens, so the evaporator pressure is transmitted to the space at the top of the main regulating valve piston through the outer pressure guide pipe, Press down the piston and open the main regulating valve. The evaporator pressure then drops to an appropriate value, which increases the temperature difference between air or other fluids and refrigerant, and improves the refrigeration capacity of the evaporator of the low-temperature chiller.
Recomendações relacionadas
-
Quando escolher o sistema de controlo de temperatura TCU?
1594Em primeiro lugar, temos de saber que a caldeira de reação tem geralmente de efetuar o controlo de temperatura necessário juntamente com a reação química do próprio material. Através da mudança de temperatura do meio circulante na camisa ...
Ver detalhes -
Peças de equipamento aeroespacial teste criogénico congelador refrigeração instruções de resolução de problemas
1892A temperatura de entrada da água de arrefecimento é demasiado baixa Congelador de temperatura ultrabaixa para testes de temperatura ultrabaixa de componentes de equipamento aeroespacial À medida que a temperatura da água de arrefecimento diminui, a pressão de descarga do compressor, a temperatura de...
Ver detalhes -
Unidade de controlo da temperatura do processo de produção de semicondutores e do processo de ensaio
1473Refrigerador de processo de ensaio de semicondutores LNEYA
Ver detalhes -
Descrição dos defeitos comuns da unidade de refrigeração com semicondutores LNEYA
2092If a high-voltage alarm occurs in the semiconductor refrigeration unit, it is necessary to check whether the external piping is blocked or dirty. Clean and remove in time. If it is an air-cooled semiconductor refrigeration device, it is necessary ...
Ver detalhes
LNEYA Refrigeradores industriais Fabricante Fornecedor