Semiconductor production process and testing process temperature control equipment
Use fluid fluorinated liquid for temperature control (minimum -100 degrees)
Gas cold and hot rapid temperature change thermal chuck
Low temperature gas cooler -120 degrees
Direct cooling cooling unit (-150 degrees)
The heating method within 40°C is heated by compressor hot air.
The Chiller ring system adopts a fully enclosed design and a magnetic drive pump.
Chiller100% helium detection, 100% safety inspection, to ensure safety and reliability.
chiller100% after 24 hours of continuous operation copy machine.

Condensador: micro-channel heat exchanger (air-cooled) plate heat exchanger (water-cooled)
Evaporador: Plate heat exchanger Throttling device: Electronic expansion valve Circulation system: The whole system is a fully closed system, low temperature does not absorb moisture in the air, does not volatilize heat transfer medium, low temperature automatically replenishes heat transfer medium into the circulation system.
Shell material: cold-rolled plate spray RAL7035
Inside the pipeline: including stainless steel SUS304, copper, ceramics, broken silicon, silicone sealant, PTFE
Control system: PLC programmable controller
Communication protocol: RS485 interface Modbus RTU protocol
Interface Ethernet Protocolo TCP/IP
Operation interface: LNEYA customized 7-inch color touch factory temperature curve display\EXCEL data export
A bomba de frequência variável pode ajustar a pressão hidráulica de circulação e o caudal
The output pressure and flow rate of circulating fluid can be set on the operation panel. Even under various customer piping conditions, without bypass piping adjustment, the output pressure can be automatically controlled at the set output pressure through the frequency conversion pump. Thereby, the power consumption of a pump can be reduced. Depending on the flow rate, bypass piping may be required
Circulation heating is possible without a heater because it is heated by the exhausted heat
Recomendações relacionadas
-
Instructions for using the hydrogenation reactor cooling and heating integrated system
641There are many accessories in the hydrogenation reactor cooling and heating integrated system, from the compressor to the electrical components. LNEYA reminds you that if you find more evaporator freezing oil, it is recommended to deal with it in ...
Ver pormenores -
Does the chip lead bonding process require a temperature control system?
425The chip lead bonding process indeed requires precise temperature control, so temperature control systems are usually equipped to ensure process stability and yield. The following are the importance and application scenarios of temperature con...
Ver pormenores -
Cautions for Ultra-low Temperature Freezer
4871. Requirements of equipment environment: To keep the outside of cryogenic refrigerator clean and ventilated, it is necessary to keep the horizontal position of cryogenic refrigerator stable, and to ensure that there are no sundries around.2. Mana...
Ver pormenores -
Precauções para uma utilização segura do equipamento de controlo da temperatura do óleo de transferência de calor
540Com a utilização extensiva de equipamento de controlo da temperatura do óleo térmico, a utilização segura do equipamento de controlo da temperatura do óleo térmico é uma preocupação para os utilizadores. Para os fabricantes, é muito importante partilhar as precauções de utilização dos equipamentos de controlo da temperatura dos óleos térmicos.
Ver pormenores