Instructions for using the hydrogenation reactor cooling and heating integrated system
There are many accessories in the hydrogenation reactor cooling and heating integrated system, from the compressor to the electrical components. LNEYA reminds you that if you find more evaporator freezing oil, it is recommended to deal with it in time.
Generally speaking, when the hydrogenation reactor is used to cool and heat the integrated system, the temperature is in the range of 100 ℃ ~ 300 ℃, the heating temperature is different, and the oil used is also different. The heating oil is used for a long time, and it should be replaced in time, otherwise the oil spill will catch fire; there is the decomposition of the vegetable oil at high temperature, and other substances can be added to increase the cooling and heating of the hydrogenation reactor. The stability of the integrated system. Be careful not to splash water in the oil bath during operation, otherwise it will generate splashes and affect the operator.
Too much refrigeration oil in the evaporator of the hydrogenation reactor cooling and heating integrated system can also cause insufficient cooling capacity and slow down the temperature. The oil stored in the evaporator can be directly judged by the hot and cold boundary of its oil surface. If the oil level is too high, it should be released in time.
Some refrigerants and refrigerator oil dissolve with each other. Therefore, when the refrigerant in the refrigeration system circulates, it is inevitable that there will be refrigerator oil remaining in each part. Hydrogenation reactor cooling and heating integrated system with frozen oil remaining in the heat exchanger will affect the heat transfer coefficient. Especially when the refrigerator oil enters the evaporator of the hydrogenation reactor cooling and heating integrated system, if the structural design or installation is unreasonable, the hydrogenation reactor cooling and heating integrated system refrigerator oil will only enter or not enter, so that There is more and more refrigerating machine oil remaining in the evaporator, which seriously affects its heat absorption effect, and there is insufficient cooling capacity. If it is not treated at this point, the temperature will not drop, so oil draining must be carried out.
It is more difficult to judge how much refrigeration oil remains in the evaporator tube and affects refrigeration. In this case, there will be an obvious anomaly, that is, the white frost on the evaporator tube is sparsely drawn, incompletely formed, and appears to be frost. If there is no other fault, it is likely to be left in the evaporator tube. There is too much oil in the refrigerator. To remove the freezing oil in the evaporator, it must be removed, rinsed and dried. For the discharge tube evaporator, because it is very inconvenient to disassemble, the inlet of the evaporator of the hydrogenation reactor cooling and heating integrated system can be blown with compressed air, and then the evaporation tube is dried with a blowtorch.
If you encounter difficult problems during use, you can contact the hydrogenation reactor cooling and heating integrated machine manufacturer-Wuxi Guanya to solve it.
Recomendações relacionadas
-
Em que aspectos devemos considerar a utilização de refrigeradores de circulação?
1417Os refrigeradores de circulação são uma escolha popular para aplicações de temperatura crítica porque proporcionam um controlo estável da temperatura, um fluxo constante e um controlo constante da pressão. Muitos sistemas de aquecimento de processos requerem arrefecimento e aquecimento. Por exemplo, o homem...
Ver detalhes -
Caraterísticas do produto do sistema de controlo da temperatura de transferência de calor de fluidos
1707O sistema de controlo da temperatura de transferência de calor de fluidos é o dispositivo de refrigeração e aquecimento do reator de correspondência na indústria química farmacêutica. Então, quais são as caraterísticas do sistema de controlo de temperatura de transferência de calor de fluido...
Ver detalhes -
Precauções de funcionamento do equipamento de controlo da temperatura do reator da série ZLF/SR
1719O equipamento de controlo da temperatura da chaleira de reação adopta o método de controlo PID, o que melhora consideravelmente a precisão do controlo da temperatura de toda a máquina. O microcomputador para arrefecimento ou aquecimento muda automaticamente para trabalhar de acordo...
Ver detalhes -
Função da bomba de água do refrigerador de água industrial
1557The water pump is one of the important auxiliary components of the refrigeration system of the industrial water chiller. Many industries will use the industrial water chiller, but many people don't know much about the equipment. This time, lneya r...
Ver detalhes
LNEYA Refrigeradores industriais Fabricante Fornecedor