Detalhes de utilização das câmaras ambientais de alta e baixa temperatura
The enterprise users must have a certain understanding of the functions of the high and low-temperature environmental chamber after using them for a long time, but something detail of the high and low-temperature environmental chamber may still not be paid attention to, so the technology department of Wuxi LNEYA has specially reorganized the related matters of attention for everyone.
Professional manufacturer of high and low-temperature environmental chambers for sale
When delivering, the tilted angle of the high and low-temperature environmental chamber should not exceed 30°. When carrying, keep the body of the high and low-temperature environmental chamber vertically, do not place it inversely or horizontally. Besides, dragging the door handle or the condenser are prohibited, otherwise, the equipment may be damaged.
The high and low-temperature environmental chamber should be electrified regularly every month during the lengthy shutdown period, and the power-on time should be more than 1h.
Professional manufacturers of high and low-temperature environmental chamber insist on taking out the test samples after each test and wipe the workroom wall of the environmental chamber to keep the inner box clean.
Cleaning and balance of the circulating blade and condenser fan: Similar to that of the cleaning evaporator, because the working environment of the environmental chamber is different, a lot of small particles like dust will condense on the circulating blade and condenser fan. Hence, they should be cleaned regularly.
The power supply voltage of the high and low-temperature environmental chamber fluctuations, such as repeated power failure. In this case, it is suggested to suspend the use of high and low-temperature environmental chamber and close the power supply to prevent the burning of the compressor. Do not start the compressor immediately after the shutdown of the high and low-temperature environmental chamber. It should be stopped for 2-5 minutes before restarting.
The condenser of the high and low-temperature environmental chamber should be cleaned every three months. The condensing fan should be regularly overhauled and the condenser should be cleaned and dedusted so as to ensure its good ventilation and heat transfer performance.
High and low-temperature environmental chamber should be placed in a well-ventilated position with low humidity and smooth ground, 60 ~ 70 cm of use and maintenance space should be left around.
During the operation of high and low-temperature environmental chamber, the frequency of door opening should be minimized and the spillage of cold air should be reduced.
The usage details of high and low-temperature environmental chamber should be used by enterprise users in daily use.
Recomendações relacionadas
-
We are LNEYA, a manufacturer of chillers
1905LNEYA chiller manufacturer is committed tothe R&D, production and sales of refrigeration and heating temperaturecontrol systems, ultra-low temperature freezers, new energy automobilecomponent testing systems, and heating cycle systems. The ...
Ver detalhes -
Considerações sobre a seleção do sistema de controlo da temperatura do sistema de destilação
2041O sistema de controlo de temperatura do sistema de destilação Lneya é um sistema de controlo de temperatura de aquecimento por refrigeração desenvolvido pela própria empresa para o equipamento de apoio à indústria de destilação, que é muito procurado na indústria de destilação. O que é que deve...
Ver detalhes -
Aplicação do sistema de controlo da temperatura de refrigeração e aquecimento na síntese química
1347síntese química arrefecimento sistema de aquecimento unidade de controlo da temperatura
Ver detalhes -
Precautions for changing the refrigerating oil in the cooling system of the car charger
1265O sistema de arrefecimento do carregador de bordo deve prestar atenção ao estado do óleo de refrigeração durante o funcionamento. Após o arranque do compressor, observar cuidadosamente as alterações da temperatura e da pressão do óleo. Se o óleo mudar...
Ver detalhes
LNEYA Refrigeradores industriais Fabricante Fornecedor










