-45 °C freezer manufacturers analyze compressor burnout detection and repair methods
In the -45 ° C freezer, the compressor is one of the more important components, the manufacturer Wuxi Guanya (LNEYA) tells everyone that once the compressor fails, it needs timely inspection and maintenance, then how to check the work and maintenance?
The core component of the refrigeration system is the compressor. The faults of the motor refrigeration compressor (hereinafter referred to as the compressor) can be divided into motor faults and mechanical faults (including crankshafts, connecting rods, pistons, valve plates, cylinder head gaskets, etc.). Mechanical failure often causes the motor to overload or even stall, which is one of the main causes of motor damage.
The damage of the -45 °C freezer motor is mainly caused by damage (short circuit) and open circuit of the stator winding insulation layer. When the stator winding is damaged, it is difficult to be discovered in time, which may cause the winding to burn out. After the windings are burnt, some phenomena or direct causes of burning are masked, making post-mortem analysis and cause investigation difficult. However, the operation of the motor is inseparable from the normal power input, reasonable motor load, good heat dissipation and protection of the winding enameled wire insulation.
The motor load includes the load required to compress the gas and the load required to overcome the mechanical friction. If the pressure ratio is too large, or the pressure difference is too large, the compression process will be more difficult; the frictional resistance caused by the lubrication failure will increase, and the motor stall in extreme cases will greatly increase the motor load. Lubrication failure and increased frictional resistance are the primary causes of load anomalies. Dilute the lubricating oil, the oil is overheated, the coking and deterioration of the lubricating oil, and the lack of oil will destroy the normal lubrication, resulting in failure of lubrication. The liquid is diluted to dilute the lubricating oil, which affects the formation of the normal oil film on the friction surface, and even washes away the original oil film, increasing friction and wear. Overheating of the -45 °C freezer compressor will cause the lubricating oil to become thinner or even coked at high temperature, which will affect the formation of normal oil film. The system does not return oil well, the compressor is short of oil, and naturally it is impossible to maintain normal lubrication. The high-speed rotation of the crankshaft and the high-speed movement of the connecting rod piston, the friction surface without the oil film protection will rapidly heat up, and the local high temperature will cause the lubricating oil to evaporate or coke rapidly, which makes the lubrication of the part more difficult and can cause local severe wear in a few seconds.
LNEYA reminds all users that when purchasing a -45 °C freezer, it is recommended to purchase from a manufacturer with a professional after-sales service team to avoid the late failure and no technical personnel to repair, resulting in increased enterprise costs, which is not conducive to work.

Recomendações relacionadas
-
Introdução de equipamento de controlo da temperatura para extração de cannabis
1042O CO2 é um solvente único porque o seu poder de dissolução pode ser alterado através do simples ajuste da temperatura e da pressão durante o processo de extração. Quando a pressão e a temperatura do CO2 são superiores a 1083 psi e a 88F, o CO2 é considerado sup...
Ver pormenores -
Quais são as principais vantagens dos refrigeradores de óleo para a indústria biofarmacêutica?
833No sistema de refrigeração do refrigerador de óleo da indústria biofarmacêutica, o compressor, o evaporador e o condensador são as partes indispensáveis do sistema de refrigeração. O condensador é o equipamento que emite calor, que se combina com o condensador...
Ver pormenores -
Instruções de manutenção do compressor do equipamento de tratamento de condensação de gás Vocs
958The vocs gas condensing treatment equipment is an important equipment in the process of exhaust gas treatment. Among them, the compressor is one of the main components, and its performance is affecting the operating efficiency of the entire vocs g...
Ver pormenores -
Ponto de instalação das instruções do fabricante de uma máquina à prova de explosão a alta e baixa temperatura
1171Depois de a máquina integrada de alta e baixa temperatura à prova de explosão ser entregue pela fábrica, deve ser instalada depois de chegar ao destino. A que é que se deve prestar atenção durante a instalação? A máquina integrada de alta e baixa temperatura à prova de explosão...
Ver pormenores