How is the electric vehicle battery test driver grounded?
If the electric vehicle battery test is not isolated between the AC power source and the drive DC bus (such as a transformer), do not connect the non-isolated port of the DC bus or the ground of the non-isolated signal to the ground, which may result in equipment damage and personal injury. Because the common voltage of the AC is not to earth, there may be a high voltage between the DC bus ground and the earth.
In most electric vehicle battery test systems, all common ground and earth are connected together at the signal end. A variety of ground loops generated by grounding are susceptible to noise and generate flow at different reference points.
In order to keep the command reference voltage constant, Wuxi Guanya LNEYA will connect the signal ground of the driver to the signal ground of the controller, and it will also be connected to the ground of the external power supply, which will affect the operation of the controller and the driver.
It is difficult to test the grounding of the shield of an electric vehicle battery. There are several methods. The correct grounding of the shield is at the reference potential point inside the circuit. This point depends on whether the noise source and the receiving are grounded at the same time, or floating. Make sure that the shield is grounded at the same point so that ground current does not flow through the shield.
For the electric vehicle battery test to maintain a stable operating state, it is necessary to understand the operation of the above accessories.

Recomendações relacionadas
-
A diferença entre pequenos chillers arrefecidos a ar e pequenos chillers arrefecidos a água no trabalho
1427Os diferentes tipos de chillers são divididos em dois tipos de acordo com o estilo, aparência, configuração incorporada, forma do condensador, etc. A dissipação de calor da unidade através do condensador aletado é chamada de chiller pequeno refrigerado a ar.
Ver pormenores -
Como escolher o gás residual orgânico para o tratamento de condensação?
1236Condensation treatment of organic waste gas equipment is currently used in the environment of environmental protection requirements, then how to choose the organic waste gas equipment for the condensation treatment, how to choose the efficient and...
Ver pormenores -
Semiconductor laser automatic temperature control equipment accessories fault solution
1136Semiconductor laser automatic temperature control compressor frosting, may be circulating water circulation or valve is not open, check the water valve, all pipelines, to ensure smooth, install short-circuit pipeline. It may be that the circulatin...
Ver pormenores -
Quais são os fluidos refrigerantes para o congelador de temperatura ultrabaixa de 120 graus?
1311Os refrigerantes dos diferentes fabricantes de congeladores de temperatura ultra baixa são diferentes. Os refrigerantes normalmente utilizados nos equipamentos de refrigeração LNEYA são R404, R22, etc. Então, qual é a diferença entre os dois refrigerantes de temperatura ultrabaixa de 120 graus...
Ver pormenores