Compressor is an important part of cryogenic refrigeration industry. As far as low temperature chiller is concerned, different brands and types need to be selected when buying compressors. Therefore, when choosing cryogenic refrigeration compressors, we should pay attention to the advantages and disadvantages of each compressor and make better choices.
The cryogenic refrigeration compressors mainly include semi-enclosed piston refrigeration compressor, rotor refrigeration compressor, screw refrigeration compressor, centrifugal refrigeration compressor and so on. The advantages and disadvantages of these cryogenic refrigeration compressors should be dialectically analyzed, and the compressor should be better used and selected.
Semi-hermetic piston refrigeration compressor is widely used in low temperature chiller. The refrigeration equipment of semi-hermetic piston refrigeration compressor has simple internal structure, low requirements for processing materials and processing technology. Compared with other compressors, semi-hermetic piston refrigeration compressor has strong adaptability, wide pressure range and semi-hermetic. The closed piston refrigeration compressor system is relatively simple, and it can meet a wide range of pressure and refrigeration capacity. But at the same time, the semi-closed piston refrigeration compressor also has some defects, such as the shape is larger and the volume is heavier, and has greater noise and vibration. It is difficult for semi-closed piston refrigeration compressor achieve high speed. It has many problems such as vulnerable parts, and inconvenient maintenance.
Rotor refrigeration compressor of refrigerador de baixa temperatura is fully enclosed. Small refrigeration equipment is used more, and its refrigeration capacity is not very prominent. Compared with other compressors, it has simple structure, small size, light weight, no suction valve, high speed, small vibration and smooth operation. At the same time, compared with other compressors, the rotor refrigeration compressor system requires higher cleanliness and processing accuracy. The leakage, friction and wear between slider and cylinder wall are larger, and the performance of the compressor decreases obviously. This is also something you need to realize. The other three devices are shown on other pages of our company.
Recomendações relacionadas
-
Quais são as caraterísticas da pressão dos refrigeradores de água industriais
1839Os refrigeradores de água industriais são um dos equipamentos mais populares na indústria de máquinas e equipamentos. Por esta razão, o editor do LNEYA compilou especialmente instruções de pressão relevantes para ajudar todos a entender melhor os refrigeradores de água industriais...
Ver detalhes -
Matters Needing Attention in Replacing Refrigerant Oil of the Screw Chiller Factory
1599The refrigerant oil in the screw chiller factory needs regular inspection and replacement. We all know that different grades of refrigerant oil cannot be mixed together, otherwise it will cause abnormal or strike conditions of the screw chiller fa...
Ver detalhes -
What are the main equipment needed for industrial chillers?
1375Main equipment of industrial chiller: compressor, condenser, expansion valve, evaporator, chilled water pump, cooling water pump cooling tower (water cooling) Selection: know the required inlet and outlet water temperature, the required cooling ca...
Ver detalhes -
How to reduce the failure rate of the new energy motor test water cooling system?
1577New energy motor test water cooling system needs to pay attention to use during use, no matter how good equipment is used for a long time, some problems will occur more or less. So, how can we minimize the failure rate of the equipment during use?...
Ver detalhes