Quais são as caraterísticas da pressão dos refrigeradores de água industriais
Industrial water chillers are one of the
most popular equipment in the machinery and equipment industry. For this
reason, the editor of LNEYA specially compiled relevant pressure instructions
to help everyone better understand industrial water chillers.
The reference value related to the pressure
resistance of industrial water coolers and piping system components refers to
the design given pressure related to the mechanical strength of the piping
components. The nominal pressure is generally expressed by PN. The nominal
pressure of the special chiller for the laboratory-the compressive strength of
the product at the reference temperature, expressed in PN, the unit: MPa, the
reference temperature: the reference temperature is different for different materials,
for example, the reference temperature of steel is 250°C, The
nominal pressure is 1.0Mpa, which is recorded as: PN 1.0 Mpa.
The working pressure of the industrial
water chiller refers to the large pressure required for the operation of the
pipeline system according to the high working temperature of the pipeline
conveyed by the medium at all levels. The working pressure is generally
expressed in Pt.
The design pressure of an industrial water
chiller refers to the large instantaneous pressure that the water supply piping
system acts on the inner wall of the pipe. Generally, the sum of the working
pressure and the residual water hammer pressure is used, and the design
pressure is generally expressed in Pe.
The test pressure of an industrial water
cooler refers to the pressure that the pipeline, container or equipment must
reach for the pressure resistance and air tightness test requirements. The test
pressure is generally expressed by Ps.
The nominal pressure of industrial water
chillers is for the convenience of design, manufacture and use, and is a
nominal pressure artificially specified. The unit of this nominal pressure is
actually the pressure, and the pressure is the common name in Chinese, and the
unit is “Pa” instead of “N”. The nominal pressure of the
pressure vessel refers to the nominal pressure of the pressure vessel flange.
The nominal pressure of the pressure vessel flange is generally divided into 7
levels, namely 0.25, 0.60, 1.00, 1.60, 2.50, 4.00, 6.40MPa.
Resumir
Generally speaking, the pressure of
industrial water chillers can be divided into: test pressure>nominal
pressure>design pressure>working pressure. If you have any other
questions, you can consult us and send an email to sales@lneya.com
Recomendações relacionadas
-
Precauções para a utilização do controlo da temperatura de arrefecimento e aquecimento da destilação molecular
1502A série SUNDI do sistema de controlo da temperatura de refrigeração e aquecimento LNEYA é utilizada em conjunto para controlar a temperatura no processo de destilação molecular. A que é que se deve prestar atenção durante a utilização? Se o método de destilação molecular ca...
Ver detalhes -
Como escolher o circulador quente e frio certo?
1615O circulador a quente e a frio é amplamente utilizado na indústria farmacêutica e química para fornecer aos utilizadores um controlo a quente e a frio, uma temperatura uniforme e uma temperatura constante. Também pode ser diretamente equipado com reactores, reactores, etc. para...
Ver detalhes -
Como tornar os chillers de recirculação de temperatura ultra baixa mais económicos em termos energéticos
1663Nos tempos modernos, a proteção ambiental e a poupança de energia são o tema do desenvolvimento, assim como o chiller industrial. Então, como melhorar o seu chiller industrial para ser mais conservação de energia? Em primeiro lugar, para prevenir e reduzir a incrustação de tubos de...
Ver detalhes -
Instruções de seleção do sistema de controlo da temperatura de refrigeração de semicondutores
2195A escolha do sistema de controlo da temperatura de refrigeração de semicondutores deve basear-se na carga de frio e no que deve ser utilizado para consideração. Para os sistemas de refrigeração com condições de funcionamento prolongado com baixa carga, é adequado selecionar...
Ver detalhes
LNEYA Refrigeradores industriais Fabricante Fornecedor