Como lidar com o mau funcionamento do sistema de arrefecimento de água industrial?
What’s wrong with the Industrial Water Chiller System when it fails to cool down?
Let LNEYA explain it to you below:
One reason is that the initial use of liquid chiller system fails to reduce the temperature, or there is something wrong with the installation of water-cooled chiller, cooling water tower, circulating water pump and pipe. It needs to be carefully checked according to the installation diagram.
The second reason may due to the pipes which are attached to various devices for a long time, and the impurities have accumulated in the water sources, resulting in smaller water flow. Therefore, we must clean the pipes between the devices.
Thirdly, If this problem occurs during the first use, it may cause by the wrong matching of the chiller and the problem of delivery. Because the industrial chiller has carried out 100% performance tests before getting out of the machine to ensure the normal operation of the machine unit.
Finally, If this is the case of a chiller that has been used for half a year or 1-2 years later, it may due to the leakage of Freon in the cooling system of the cold water machine. It is suggested to find out the leakage, weld it again and refrigerant. The heat exchanger of the water-cooled chiller is dirty and needs washing, and remember to clean it regularly after subsequent use.
The operation of any Industrial Water Chiller System is inseparable from the participation of refrigerant. So the shortage of refrigerant will affect the normal operation of the industrial chiller, and then result in the reduction of refrigerating capacity of the industrial chiller and even shut down, which is also the main reason for the shrinkage of the refrigerating capacity of the industrial chiller.

Recomendações relacionadas
-
Os ensaios de motores de veículos de energia nova requerem um refrigerador ou aquecedor?
765O ensaio de motores de veículos de energia nova requer um refrigerador e um aquecedor, uma vez que o ensaio de motores abrange uma vasta gama de condições de temperatura para garantir o desempenho e a estabilidade do motor em diferentes condições de funcionamento. Refrigerador: Em ...
Ver pormenores -
Application of supporting experimental equipment for refrigeration and heating system
1192The mixing tank with jacket and insulation layer is a three-layer insulation mixing tank with heating function, which has the functions of heating, insulation, mixing, etc. It is widely used in dairy, chemical, food, beverage, pharmaceutical, phar...
Ver pormenores -
Como é que o sistema de refrigeração do frigorífico criogénico é drenado?
1598Users who use ultra-low temperature chillers will encounter some problems when they are not used for a long time, such as poor cooling performance and loud sound. These problems are more common, but some refrigeration systems need to be well under...
Ver pormenores -
Quais são as causas da corrosão nos refrigeradores industriais / refrigeradores de água?
1394Industrial chillers are now widely used in various industries, but as they become more and more widely used, many problems slowly emerge. Corrosion problems are also relatively common. Because everyone does not use the standard and the maintenance...
Ver pormenores