Pontos principais de manutenção de dez fabricantes de câmaras de teste de alta e baixa temperatura
According to many years’ production experience of high and low temperature test chamber in Wuxi Guanya, it is found that many users are not very familiar with the maintenance of high and low temperature test chamber. As one of the top ten manufacturers of high and low temperature test chamber, Wuxi Guanya has sorted out the relevant maintenance points, and everyone pays attention to the analysis.
Enterprise users need to have a comprehensive understanding of the products of ten manufacturers of high and low temperature test chamber before choosing. Because of the lack of correct judgment and sufficient recognition, enterprises can not choose high-quality high and low temperature test chamber. Among them, compressors, controllers, electronic devices, boxes and hardware fittings are very important, so the role of each component is very important and nursing is very important.
Cleaning of waterway and humidifier
If the waterway of the high and low temperature test chamber is not smooth, the scaling of the humidifier will easily lead to the dry burning of the humidifier, which may damage the humidifier. Therefore, the high and low temperature test chamber must be cleaned regularly for the waterway and the humidifier.
Selection of Test Environment
Generally speaking, the box of high and low temperature test chamber is relatively high. Ten manufacturers of high and low temperature test chamber suggest that it should be placed in a benign temperature environment when using. For laboratories that do not meet this requirement, it is necessary to equip with appropriate air conditioners.
Clean evaporator regularly
Many small particles such as dust will condense on the evaporator under the forced air circulation of the test sample in the high and low temperature test chamber. It needs to be cleaned regularly in the high and low temperature test chamber, otherwise it will seriously affect the normal use of the equipment.
Clean condenser regularly
The common high and low temperature test chamber usually uses air-cooled cooling compressor, so it is necessary to repair the condenser fan regularly and remove the dirt and dust from the condenser so as to obtain good ventilation and heat transfer performance.
These high and low temperature test chamber ten manufacturers collated the relevant maintenance knowledge, you can pay attention to check the early formulation of maintenance plan.
Recomendações relacionadas
-
Qual é o refrigerante do equipamento de arrefecimento por circulação de água?
1589Diferentes indústrias exigem diferentes temperaturas de refrigeração para o equipamento de arrefecimento de água em circulação, pelo que os refrigerantes selecionados também são diferentes. Ao escolher o equipamento de arrefecimento por circulação de água, também é necessário ter um conhecimento claro das...
Ver detalhes -
A razão pela qual o circulador de água de arrefecimento necessita da circulação de água principal
1894O suplemento do ciclo da água é direcionado para um circulador de água de refrigeração arrefecida a água, e o circulador de água de refrigeração arrefecida a ar não tem este problema. O circulador de água de arrefecimento arrefecido a água necessita de água de arrefecimento durante o funcionamento normal...
Ver detalhes -
A que é que deve prestar atenção ao instalar um sistema de arrefecimento de uma pilha de carga DC?
1392pay attention to when installing a DC charging pile cooling system
Ver detalhes -
Ponto de instalação das instruções do fabricante de uma máquina à prova de explosão a alta e baixa temperatura
1758Depois de a máquina integrada de alta e baixa temperatura à prova de explosão ser entregue pela fábrica, deve ser instalada depois de chegar ao destino. A que é que se deve prestar atenção durante a instalação? A máquina integrada de alta e baixa temperatura à prova de explosão...
Ver detalhes
LNEYA Refrigeradores industriais Fabricante Fornecedor