Como evitar que a pressão de congelação da caixa de congelação rápida de rolamentos seja demasiado baixa?
In the refrigeration system of the bearing blast chiller, if the condenser installation is not in the enclosed space, the system’s exhaust pressure (condensation pressure) tends to be lower in winter (or low temperature), which is often more common in the north. For bearing blasters, this is also the case for other equipment.
The low condensing pressure of the bearing quick freezing box will make the expansion valve unable to obtain sufficient pressure drop at both ends, and it is difficult to supply the appropriate refrigerant to the evaporator. On the one hand, the cooling capacity of the refrigeration system will not meet the requirements, and the system will also be made. Frequent low-voltage alarms and other faults.
To this end, we can deal with the method of exhaust pressure controller. When the intermittent operation of the fan is simple and easy to use, and the technology is mature, the controller used is a pressure controller. This pressure controller can control the intermittent start and stop of the fan. When the pressure is too low, turn off the fan. When the pressure is too high, turn on the fan. Generally, on a small-capacity unit, use two or more fans, one of which is normally open, and the other fans are pressure controlled. The controller controls the start or stop of the fan by the level of the condensing pressure.
It is also possible to use a pneumatic control device to utilize a high-pressure refrigerant-driven piston-type damper. This control device can operate as a stable exhaust pressure as the fan speed controller; the main reason is that the inlet pressure of the expansion valve does not resemble a fan. Intermittent operation produces large fluctuations, and the louver device can be installed either at the air inlet or at the air outlet.
In addition, the condenser overflow device can also be used to increase the condensing pressure of the system by using excess refrigerant, and the condenser overflow device is used for warming or low temperature environment, and the large flow refrigerant is taken from the liquid storage device. It is sent to the condenser, and the excess refrigerant is used to increase the condensing pressure of the system, thereby avoiding the failure of the condensing pressure being too low at low temperatures.
LNEYA’s methods to prevent the bearing chiller from condensing too low pressure are still relatively high, and users can try it according to their own needs.

Recomendações relacionadas
-
Método de inspeção do dispositivo de ensaio ambiental de célula de combustível comum
1164Durante o processo de arrefecimento do dispositivo de ensaio ambiental de célula de combustível, existe a possibilidade de pingar no interior. Não se trata de um fenómeno normal utilizado pelo dispositivo de ensaio ambiental das pilhas de combustível, mas sim de uma instalação incorrecta. Depois de o dispositivo de teste ambiental...
Ver pormenores -
Selection of Temperature Control System for Laboratory Resin Reaction Kettle
10161. Choose from the quality of the laboratory resin reactor temperature control system: can affect the quality of the laboratory resin reactor temperature control system, may be the use of accessories. There are some small factories on the market t...
Ver pormenores -
Princípio de refrigeração do sistema de refrigeração de glicol LNEYA
930Sistema de resfriamento de glicol SUNDI -10 ℃ ~ 200 ℃, como podemos dizer a partir de seu nome, é usar Glycol como o agente de refrigeração para o chiller.No ambiente todo o ar, por causa da baixa temperatura no exterior, é impossível usar um resfriamento para...
Ver pormenores -
Sistema de simulação de arrefecimento para ensaio de desempenho extremo de baterias
1125Com o desenvolvimento da tecnologia, os veículos eléctricos puros estão a tornar-se cada vez mais comuns, mas os veículos eléctricos puros são difíceis de obter uma solução melhor em termos de autonomia de cruzeiro, velocidade de carregamento e poluição após o desperdício da bateria. Isso faz com que...
Ver pormenores