Energy storage system requirements for temperature-controlled liquid-cooled unit

Energy storage system: It needs to meet the discharge demand for a long time. It is suitable for energy storage on the side of new energy generation, arbitrage of peak-valley price difference on the user side, etc. The future trend is that the project capacity will continue to expand. Under the trend of high installed capacity growth of new energy power generation projects such as wind energy and solar energy + expansion of distribution and storage ratios, energy storage projects on the power generation side are expected to accelerate their growth and production capacity will also expand. Therefore, for energy storage projects, the increase in battery system capacity will increase the calorific value of the project, and the demand and importance of thermostats will increase accordingly.
Secondly, in the design and development stage of the energy storage system, it is necessary to test the energy density. The ambient temperature needs to be controlled during the test to ensure the accuracy of the test results. Our liquid coolers provide them with a stable ambient temperature.
Energy storage systems are usually installed in a closed environment, and the environment needs to be controlled to ensure the stable operation of the energy storage system. Our devices can provide stable temperature control for energy storage systems while controlling indoor air quality. In the operation of the vehicle energy storage system, other auxiliary equipment will be used, and these equipment also need to be cooled and controlled by constant temperature.
The temperature control system can keep the temperature of the energy storage battery equipment within a reasonable range of 10-35°C, effectively preventing thermal runaway, and is a key link in the security of the energy storage system. The temperature is 15°C~35°C; the relative humidity is between 5%-95%, without condensation; this avoids local hot spots in the battery system: the temperature difference between the cells does not exceed 5°C to avoid local hot spots. With the trend of mass storage systems and high battery rates, temperature controllers are becoming more and more important. Additionally, temperature control increases lifetime decay by reducing temperature differences between cells.
The industry barriers of energy storage temperature control are mainly reflected in temperature control capabilities, product customization capabilities, and cost control capabilities. As an important part of energy storage systems, thermal management systems will benefit from the growth of installed energy storage capacity, and the energy storage temperature control market may continue to expand. We, LNEYA, are a manufacturer with 16 years of experience in manufacturing industrial temperature control equipment. We have pharmaceutical and chemical industries, new energy batteries, automobiles, semiconductors and other enterprise customer groups, so we are also very selective in the energy storage industry.
RECOMMENDED PRODUCTS
Sistema de arrefecimento de um armário refrigerador de armazenamento de energia arrefecido a líquido
1122Com o desenvolvimento de novas tecnologias energéticas, aumentou a aplicação de sistemas de armazenamento de energia em contentores em novas estações de energia, fotovoltaicas e eléctricas. Se a temperatura da bateria de armazenamento de energia não estiver bem...
Resfriador de resfriamento líquido(Armazenamento de energia comercial)
2338Os sistemas de armazenamento de energia da bateria são preenchidos com muitas células de bateria, gerando uma grande quantidade de carga térmica extrema. Isto significa que o sistema de arrefecimento tem de controlar com precisão a temperatura e dissipar eficazmente o calor...
Resfriador de resfriamento líquido(Pilha de carregamento)
2262Modelo CHDYL-4 -45 ℃ ~ 55 ℃ Potência de resfriamento 4KW Precisão do controle de temperatura ± 1 ℃ Registro de temperatura em tempo real Sistema de circulação de salmoura refrigerante Projeto totalmente fechado Fluxo 1.8 ~ 5.5L / min Pressão 0.7bar Temperatura mínima de entrada de água 15 ° C ...
Resfriador de resfriamento líquido(Armazenamento de energia)
3196Model CNYL -45~55 Cooling Capacity 45KW Temperature Control Accuracy ±0.5℃ Real-time temperature record Secondary Refrigerant Ethylene glycol antifreeze, fully enclosed design of refrigerant circulation system Refrigerant R41…
carregando...
已经是到最后一篇内容了!
Recomendações relacionadas
-
Análise de simulação e análise de resultados da gestão térmica de baterias
1036análise de simulação da gestão térmica de baterias
Ver pormenores -
Caraterísticas do refrigerador de temperatura ultrabaixa
1075The ultra low temp chiller is controlled by microcomputer, and the refrigeration compressor and its system components are energy-saving products, which greatly improves the reliability of the whole machine. The unit can realize multi-stage energy ...
Ver pormenores -
Refrigeration Principle Of Low Temperature Chiller
943The refrigeration principle of the so-called low temperature chiller is to use the artificial method, compressor refrigeration, through energy consumption, in a cycle process, in the process that cooling materials take away the heat. Generally spe...
Ver pormenores -
16. - 18. junho de 2020 | A Exposição de Ensaios Automóveis da Europa-LNEYA
1373A Automotive Testing Expo Europe é uma feira de testes, avaliação e engenharia de qualidade para o sector automóvel. É um dos eventos mais importantes do seu género na Europa, onde são apresentadas as mais recentes tecnologias e serviços para melhorar a qualidade, a segurança e a...
Ver pormenores