Como lidar com o mau funcionamento do sistema de arrefecimento de água industrial?
What’s wrong with the Industrial Water Chiller System when it fails to cool down?
Let LNEYA explain it to you below:
One reason is that the initial use of liquid chiller system fails to reduce the temperature, or there is something wrong with the installation of water-cooled chiller, cooling water tower, circulating water pump and pipe. It needs to be carefully checked according to the installation diagram.
The second reason may due to the pipes which are attached to various devices for a long time, and the impurities have accumulated in the water sources, resulting in smaller water flow. Therefore, we must clean the pipes between the devices.
Thirdly, If this problem occurs during the first use, it may cause by the wrong matching of the chiller and the problem of delivery. Because the industrial chiller has carried out 100% performance tests before getting out of the machine to ensure the normal operation of the machine unit.
Finally, If this is the case of a chiller that has been used for half a year or 1-2 years later, it may due to the leakage of Freon in the cooling system of the cold water machine. It is suggested to find out the leakage, weld it again and refrigerant. The heat exchanger of the water-cooled chiller is dirty and needs washing, and remember to clean it regularly after subsequent use.
The operation of any Industrial Water Chiller System is inseparable from the participation of refrigerant. So the shortage of refrigerant will affect the normal operation of the industrial chiller, and then result in the reduction of refrigerating capacity of the industrial chiller and even shut down, which is also the main reason for the shrinkage of the refrigerating capacity of the industrial chiller.

Recomendações relacionadas
-
Why is there air in the reactor temperature control system?
939The impurity gas in the reactor temperature control system is to increase the condensing pressure of the refrigeration system, thereby increasing the condensing temperature, increasing the exhaust temperature of the compressor, increasing the powe...
Ver pormenores -
Qual é o papel do circulador de refrigeração e aquecimento do reator? Como escolher?
1021O circulador de refrigeração e aquecimento é um dispositivo que pode proporcionar um controlo preciso da temperatura do reator. Pode realizar funções de aquecimento e arrefecimento ao mesmo tempo. É adequado para processos de reação química que exijam p...
Ver pormenores -
Instruções para os fabricantes de congeladores de placas frias [-5 a -150 graus de refrigeração]
1077There are various manufacturers of Low Temperature low temperature cold plate freezer. It is widely used in glass reactor, metal reactor and bioreactor to control temperature and temperature.Using Range of Low Temperature Cold Plate FreezerMediu...
Ver pormenores -
How to choose a glass reactor? How to match the temperature control system?
950Glass kettle reactors are required for many laboratory equipment and are generally used with temperature control systems. In the chemical and pharmaceutical fields, the imported glass reactor is basically a necessity, and the refrigeration heatin...
Ver pormenores