Pesquisar toda a estação

Sistema de forçagem de temperatura
Corrente térmica

Temperature-controlled gas is delivered through the robotic arm to the airflow hood for direct high- and low-temperature shock testing of semiconductors and electronic components.

AES temperature forcing system

< 10 s

from 150°C to -55°C

Up to 15°C/min

Rapid Heating

±0.1°C

Controle preciso de temperatura

-120°C to +225°C

Wide Temperature Range

100 m³/h Max

High Airflow Capacity

AES Series thermo stream

LNEYA Thermal Stream uses gas as the heat transfer medium to deliver controlled heating and cooling directly to the device under test (DUT). Compressed air passes through a pressure regulator and built-in dryer before entering a heat exchanger, where refrigerant-based cooling or heating adjusts the gas temperature. The conditioned gas then flows through pipelines along a robotic cantilever arm to the target area, with temperature regulated by DUT or outlet-gas feedback.
 
The system features automatic robotic positioning and optional airflow hoods for localized temperature testing. It is designed for high- and low-temperature shock testing, temperature cycling, and performance characterization of semiconductor chips, optical transceivers, ICs, MLCCs, wafer test setups, automotive electronics, and power devices, as well as reliability testing and failure analysis.

Explore Our Temperature Forcing Systems

AES temperature forcing system

AES-8035

  • Gama de temperaturas-80°C to +225°C
  • Temperature Stability±0.1°C at steady-state outlet
  • Temperature Transition Rate150°C to -55°C in under 10 seconds
  • Heating Capacity3 kW
  • Maximum Gas Flow Rate30 m³/h
  • refrigeranteR404/R508
Série AES

AESR-8035/AESR-8035C

  • Gama de temperaturas-80°C to +225°C
  • Temperature Stability±0.1°C at steady-state outlet
  • Temperature Transition Rate150°C to -55°C in under 10 seconds
  • Heating Capacity3 kW
  • Maximum Gas Flow Rate30 m³/h
  • refrigeranteR744 / R508B

Série AES Corrente térmica Technical Specifications

Equipment ModelAES-8035
Gama de temperaturas-80℃ ~ 225℃ (adjustable)
Potência de aquecimento3kW
Air Cooling Capacity≤500LPM( 30m³/H)
Air Supply RequirementsTemperature: <35℃, pressure: 0.5~1MPa, dew point temperature: <10℃, solid particle size: <0.1µm, maximum oil content: 0.01mg/m³
Tamanho da ligaçãoAir Inlet PT1/2
Temperature MonitoringOutlet gas temperature: T-type thermocouple
Workpiece temperature: T-type thermocouple, K-type thermocouple
Gas Flow Rate MonitoringGas Flow Rate Sensor
EcrãOutlet gas temperature display, workpiece temperature display, supply gas flow rate display.
Control PanelHuman-machine Intelligent Interface
Modo de controloThe equipment uses PLC control and supports preset multi-segment program mode control.
High-temperature CoolingFeatures direct cooling technology from a high temperature of 225℃, meeting the requirement for rapid cooling during high-temperature operation.
Fonte de alimentaçãoMAX 6kW     220V 50HZ/60HZ
Display FunctionsPerformance parameter testing and display:
(1) Nozzle and workpiece temperature display (display screen);
(2) Supply gas flow rate display (gas flow meter);
Operating status indication:
(1) Power on/off;
(2) Unit working status;
(3) Alarm value display and recording; buzzer alarm prompt
ModeloAESR-8035
AESR-8035C
Set Temperature Range ℃-80~+225℃
Temperature Stability ℃±0.1 (outlet steady state)
Método de arrefecimentoArrefecimento por ar
Temperature Control MethodOutlet gas temperature (T-type thermocouple)
/ Workpiece temperature (T-type, K-type thermocouple)
Refrigerant UsedR744/R508B
Ambient Temperature ℃20~30
Ambient Humidity %RH30~70
Altitude mBelow 3,000
Tipo de gásCompressed Air
Air Inlet RequirementsAir supply requirements: temperature <35℃, pressure 0.5~1MPa, dew point temperature <10℃
Solid particle size <0.1µm, maximum oil content 0.01mg/m³
Heating Capacity W3000
Maximum Gas Handling Capacity30m³/h
Pressure Range0.6~0.8Mpa
Heat Exchanger TypePermutador de calor de placas
Connection Size (Inlet)Rc1/2
Connection Size (Outlet)Rc3/8
Voltage V1~220V±10[%],50Hz±5Hz 
High Temperature ProtectionSensor de temperatura
High-pressure ProtectionPressure Sensor
Compressor OverloadCircuit Breaker
Flow ProtectionFlow Meter
Leakage ProtectionLeakage Protector
Overall Dimensions mm510W*780D*1100H(mm)
Peso kg260
Unit Noise dB(A)70

Need Help Choosing the Right Temperature Forcing System?

Tell us your process temperature, application, and temperature control requirements. Our team can help identify a suitable series for your application.

Gas temperature can drop from 150°C to -55°C in less than 10 seconds, enabling rapid high-to-low temperature testing without stopping the system for a temperature change.

airflow shield-AES
robotic arm lifting button-AES

AES supports both DUT temperature control and outlet gas temperature control. In DUT control mode, a thermocouple measures the device temperature in real time, and the control system adjusts the outlet gas temperature based on sensor feedback. Engineers can control the actual temperature of chips and electronic components during testing.

A robotic cantilever arm positions the gas delivery line at the target test point, while optional airflow hoods in five sizes accommodate different DUT dimensions and test setups.

Série AES
Série AES

Compressed air passes through a pressure regulator and built-in dryer before entering the heat exchanger, where the refrigerant circuit cools or heats the gas to the target temperature. The built-in dryer reduces the gas dew point to below -70°C. For sustained testing below -60°C, an external DR-series dryer is recommended when the available compressed air does not meet the required dryness, helping prevent ice buildup at the outlet that can restrict gas flow or interrupt testing.

The PLC supports multi-step temperature programs with preset target temperatures or scheduled ramp rates, such as reaching a specified temperature within 10 minutes. Engineers can automate temperature sequences for chip characterization, temperature cycling, and repeatable component testing, or use manual mode for continuous output at a fixed temperature. Remote PC control is also supported.

temperature forcing system(images 1)

The AES temperature forcing system delivers heated or cooled gas directly to chips, optical modules, ICs, and other electronic components for temperature-dependent testing. Engineers use it to evaluate electrical and optical performance at different temperatures, investigate temperature-related failures, and verify device reliability under thermal stress.

We independently develop and manufacture Thermal Stream systems, with customized configurations to meet specific temperature ranges, DUT requirements, and testing conditions.

worker-discuss

Related Gas Cooling Systems

Yes. The system can be configured for different testing environments, including probe stations, semiconductor test platforms, and automated test setups. Before integration, our engineers can review your equipment layout, DUT positioning, available interfaces, and testing workflow to recommend a suitable configuration.

The system delivers conditioned gas directly to the target area, allowing localized temperature testing without placing the entire test setup inside a temperature chamber. Airflow direction and hood configuration can be selected according to the DUT geometry and testing requirements. For sensitive measurements, airflow conditions should be evaluated during setup to minimize potential interference.

The appropriate hood depends on the size and shape of the DUT, the required test area, the distance between the outlet and the device, and the desired airflow coverage. Sharing your DUT dimensions and a photo or drawing of the test setup will help our engineers recommend a suitable hood configuration.

The system can support different DUT configurations, provided the positioning, airflow delivery, and temperature requirements are compatible. For applications involving multiple test locations or different device geometries, the required configuration should be evaluated in advance to determine whether adjustments to the robotic arm, hood, or test procedure are needed.

To help us evaluate your application, please provide the DUT type and dimensions, target temperature conditions, required test sequence, available compressed-air supply, existing test equipment, and any special measurement or automation requirements. Drawings, photographs, or a description of your current testing process are also helpful.

Yes. Configuration options can be evaluated according to the application, DUT geometry, installation space, control requirements, and integration needs. For specialized semiconductor, optical, automotive electronics, or other component testing, our engineering team can discuss the feasibility of a suitable solution based on your specific requirements.

contactar-nos

TEL:

EMAIL:

WeChat e WhatsApp:

temperature forcing system(images 2)
+86 18914253067
Wechat QR
temperature forcing system(images 3)
+86 18914253067 WhatsApp QR
*
*
*
Submissões em curso....
Submissão bem sucedida!
A submissão falhou! Tente novamente mais tarde
Erro de correio eletrónico!
Número de telefone errado!