Sistema de forçagem de temperatura
Corrente térmica
Temperature-controlled gas is delivered through the robotic arm to the airflow hood for direct high- and low-temperature shock testing of semiconductors and electronic components.

< 10 s
from 150°C to -55°C
Up to 15°C/min
Rapid Heating
±0.1°C
Controle preciso de temperatura
-120°C to +225°C
Wide Temperature Range
100 m³/h Max
High Airflow Capacity

Localized Temperature Testing with Thermal Stream
LNEYA Thermal Stream uses gas as the heat transfer medium to deliver controlled heating and cooling directly to the device under test (DUT). Compressed air passes through a pressure regulator and built-in dryer before entering a heat exchanger, where refrigerant-based cooling or heating adjusts the gas temperature. The conditioned gas then flows through pipelines along a robotic cantilever arm to the target area, with temperature regulated by DUT or outlet-gas feedback.
The system features automatic robotic positioning and optional airflow hoods for localized temperature testing. It is designed for high- and low-temperature shock testing, temperature cycling, and performance characterization of semiconductor chips, optical transceivers, ICs, MLCCs, wafer test setups, automotive electronics, and power devices, as well as reliability testing and failure analysis.
Explore Our Temperature Forcing Systems

AES-8035
- Gama de temperaturas-80°C to +225°C
- Temperature Stability±0.1°C at steady-state outlet
- Temperature Transition Rate150°C to -55°C in under 10 seconds
- Heating Capacity3 kW
- Maximum Gas Flow Rate30 m³/h
- refrigeranteR404/R508

AESR-8035/AESR-8035C
- Gama de temperaturas-80°C to +225°C
- Temperature Stability±0.1°C at steady-state outlet
- Temperature Transition Rate150°C to -55°C in under 10 seconds
- Heating Capacity3 kW
- Maximum Gas Flow Rate30 m³/h
- refrigeranteR744 / R508B
Série AES Corrente térmica Technical Specifications
| Equipment Model | AES-8035 |
| Gama de temperaturas | -80℃ ~ 225℃ (adjustable) |
| Potência de aquecimento | 3kW |
| Air Cooling Capacity | ≤500LPM( 30m³/H) |
| Air Supply Requirements | Temperature: <35℃, pressure: 0.5~1MPa, dew point temperature: <10℃, solid particle size: <0.1µm, maximum oil content: 0.01mg/m³ |
| Tamanho da ligação | Air Inlet PT1/2 |
| Temperature Monitoring | Outlet gas temperature: T-type thermocouple |
| Workpiece temperature: T-type thermocouple, K-type thermocouple | |
| Gas Flow Rate Monitoring | Gas Flow Rate Sensor |
| Ecrã | Outlet gas temperature display, workpiece temperature display, supply gas flow rate display. |
| Control Panel | Human-machine Intelligent Interface |
| Modo de controlo | The equipment uses PLC control and supports preset multi-segment program mode control. |
| High-temperature Cooling | Features direct cooling technology from a high temperature of 225℃, meeting the requirement for rapid cooling during high-temperature operation. |
| Fonte de alimentação | MAX 6kW 220V 50HZ/60HZ |
| Display Functions | Performance parameter testing and display: (1) Nozzle and workpiece temperature display (display screen); (2) Supply gas flow rate display (gas flow meter); Operating status indication: (1) Power on/off; (2) Unit working status; (3) Alarm value display and recording; buzzer alarm prompt |
| Modelo | AESR-8035 AESR-8035C |
| Set Temperature Range ℃ | -80~+225℃ |
| Temperature Stability ℃ | ±0.1 (outlet steady state) |
| Método de arrefecimento | Arrefecimento por ar |
| Temperature Control Method | Outlet gas temperature (T-type thermocouple) / Workpiece temperature (T-type, K-type thermocouple) |
| Refrigerant Used | R744/R508B |
| Ambient Temperature ℃ | 20~30 |
| Ambient Humidity %RH | 30~70 |
| Altitude m | Below 3,000 |
| Tipo de gás | Compressed Air |
| Air Inlet Requirements | Air supply requirements: temperature <35℃, pressure 0.5~1MPa, dew point temperature <10℃ Solid particle size <0.1µm, maximum oil content 0.01mg/m³ |
| Heating Capacity W | 3000 |
| Maximum Gas Handling Capacity | 30m³/h |
| Pressure Range | 0.6~0.8Mpa |
| Heat Exchanger Type | Permutador de calor de placas |
| Connection Size (Inlet) | Rc1/2 |
| Connection Size (Outlet) | Rc3/8 |
| Voltage V | 1~220V±10[%],50Hz±5Hz |
| High Temperature Protection | Sensor de temperatura |
| High-pressure Protection | Pressure Sensor |
| Compressor Overload | Circuit Breaker |
| Flow Protection | Flow Meter |
| Leakage Protection | Leakage Protector |
| Overall Dimensions mm | 510W*780D*1100H(mm) |
| Peso kg | 260 |
| Unit Noise dB(A) | 70 |
Need Help Choosing the Right Temperature Forcing System?
Tell us your process temperature, application, and temperature control requirements. Our team can help identify a suitable series for your application.
Rapid Temperature Transitions
Gas temperature can drop from 150°C to -55°C in less than 10 seconds, enabling rapid high-to-low temperature testing without stopping the system for a temperature change.


Direct DUT Temperature Control
AES supports both DUT temperature control and outlet gas temperature control. In DUT control mode, a thermocouple measures the device temperature in real time, and the control system adjusts the outlet gas temperature based on sensor feedback. Engineers can control the actual temperature of chips and electronic components during testing.
Robotic Positioning and Airflow Hoods
A robotic cantilever arm positions the gas delivery line at the target test point, while optional airflow hoods in five sizes accommodate different DUT dimensions and test setups.


Gas Cooling, Heating and Drying
Compressed air passes through a pressure regulator and built-in dryer before entering the heat exchanger, where the refrigerant circuit cools or heats the gas to the target temperature. The built-in dryer reduces the gas dew point to below -70°C. For sustained testing below -60°C, an external DR-series dryer is recommended when the available compressed air does not meet the required dryness, helping prevent ice buildup at the outlet that can restrict gas flow or interrupt testing.
Programmable Temperature Profiles
The PLC supports multi-step temperature programs with preset target temperatures or scheduled ramp rates, such as reaching a specified temperature within 10 minutes. Engineers can automate temperature sequences for chip characterization, temperature cycling, and repeatable component testing, or use manual mode for continuous output at a fixed temperature. Remote PC control is also supported.

Temperature Forcing System Applications
The AES temperature forcing system delivers heated or cooled gas directly to chips, optical modules, ICs, and other electronic components for temperature-dependent testing. Engineers use it to evaluate electrical and optical performance at different temperatures, investigate temperature-related failures, and verify device reliability under thermal stress.
Semiconductor & ICs
Chip characterization, temperature testing and
failure analysis
Passive Components
MLCC temperature screening and
electrical verification
Optical Transceivers
Optical performance and
bit error rate testing
Wafer-Level Testing
Wafer and probe station temperature testing
Automotive Electronics
ECU, sensor and power module testing
Rubber & Tires
Low-temperature brittleness and TR testing
Custom Thermal Stream Solutions
We independently develop and manufacture Thermal Stream systems, with customized configurations to meet specific temperature ranges, DUT requirements, and testing conditions.

Related Gas Cooling Systems

LQ -110℃~-40℃
Provides cooling only, discharging cooled gas directly to the target without recirculation.
Caudal de gás 15m³/h~100m³/h
Disjuntor 10A~25A
Temperatura mais baixa -40℃/-75℃/-110℃

AET -75℃~250℃
Provides both cooling and heating in a fixed installation without a robotic arm.
Temp range Gas outlet ± 0.1℃, remote ± 0.5℃
Manuseamento de ar 22m³/h~95m³/h
Taxa de aquecimento e arrefecimento <10s

AI -105℃~125℃
Provides both cooling and heating with a closed-loop gas circuit that recirculates the gas for reuse.
Potência de aquecimento 3,5KW
Capacidade de arrefecimento 1KW~3,5KW
Precisão da temperatura ±0,05℃

DR series Gas Dryer
Removes moisture from compressed gas to help prevent ice buildup during low-tem testing.
Gama de pressão 0,65~1,0Mpa
Temperatura do ponto de orvalho -70℃
Capacidade de processamento de gás 425L/Min~1750L/Min
Perguntas frequentes
contactar-nos
TEL:
EMAIL:
WeChat e WhatsApp:

Wechat QR

LNEYA Industrial Chillers Manufacturer