Pesquisar toda a estação

Six-channel chiller

KRY 0℃~100℃ six-channel chiller

Capacidade de arrefecimento 25kW~60kW
Bomba de circulação MAX
2~25L/min 0.2~2.5bar
Precisão de temperatura ±0,3℃
Potência AC380V/ AC460V

KRY 0~100 six-channel chiller adopts water cooled type. The temperature of this six channels is uniform, but the flow rate and pressure are controlled independently. If your industry need to control temperature, flow rate and pressure simultaneously, LNEYA support customization for you. Its temperature control accuracy is around 0.3℃. The flow control accuracy of each channel is around 0.2L/min. The pressure control of each channel is 0.2bar~2.5bar. The centrifugal pump KRY 0~100 six-channel chiller uses can be optionally equipped with magnetic drive pump.

Six-channel chiller parameters

0°C

mais baixo

100°C

Mais alto

±0.3°C

Precisão do controlo da temperatura


Modelo KRY-A25W/6S KRY-A38W/6S KRY-A60W/6S
Gama de temperaturas 0℃~+100℃
Precisão do controlo do caudal/Grupo 2~25 L/min 2~25 L/min 2~25 L/min
Flow rate accuracy/group ±0,2L/min
Number of fuid output groups 6 grupos 6 grupos 6 grupos
Pressure control/group 0,2bar~2,5bar 0,2bar~2,5bar 0,2bar~2,5bar
Descrição da pressão de fluxo A unidade pode controlar o fluxo individualmente ou separadamente. Necessidade de controlar diferentes soluções ao mesmo tempo (personalizado)
Capacidade de aquecimento 15kW 25kW 38kW
Capacidade de arrefecimento 100℃ 25kW 38kW 60kW
20℃ 25kW 38kW 60kW
5℃ 18kW 27kW 42kW
Water-cooled type W @20℃ 6000L/H
DN32
9000L/H
DN40
15000L/H
DN50
Potência 380V50HZ 38kW 55kW 82kW
Dimensão cm 200*145*205 200*145*205 200*145*205

Feedback de temperaturak

Feedback de temperatura PT100 (temperatura de entrada, temperatura de saída)


Compressor

Compressores Highly, Mitsubishi, Panasonic e outros


Protocolo de comunicação

Protocolo MODBUS RTU Interface RS485



KRY -40℃~100℃
refrigeradores de bateria

KRYZ -40℃~100℃
arrefecedor de anticongelante

KRY -40℃~100℃ Multi-canal
refrigerador de refrigeração líquida

You can trust lneya chiller units

Serviço global

Mais de 30.000 clientes.
Mais de 20 países.

Patentes de certificação

Certificação CE, SGS, ISO.

Serviço pós-venda

24/7 solutions.1 year warranty

Equipa profissional

Mais de 15 anos de experiência.

Controlo de qualidade

Teste de qualidade.

FAQ About Six-Channel Chiller

In present, there are two methods for controlling flow rate and pressure in the market. One is to adjust the main path and bypass through a proportional valve, and the other is to control the variable frequency pump through a frequency converter. The proportional valve adjustment is generally applied in the normal temperature section and high-temperature section. This method is suitable for cases where the required response time is long, the flow control accuracy is not high (around 0.3L/min). If high-precision control, short response time and low-temperature resistance are required, the general proportional valve spool can not meet the requirements. The cost of imported high-precision proportional valves is high, and they are prone to leakage at low temperatures. The adjustment method of controlling the variable frequency pump through a frequency converter avoids the defects of the proportional valve.

When purchasing a multi-channel chiller, it is necessary to evaluate various technical indicators, safety performance and subsequent service guarantees based on the specific application requirements and conditions.

*
*