What is a laboratory glycol chiller What should I pay attention to
The laboratory glycol chiller is a common
cooling equipment in the laboratory. It is generally used to achieve the
temperature requirement of the cold source. What are the benefits?
1. Why choose a laboratory glycol chiller:
The single-machine self-cascade
refrigeration technology adopted has fast refrigeration speed, low noise and
simple installation. There are many sizes and models of laboratory
low-temperature refrigeration cycle devices. Users can choose models according
to their own needs, and can also choose isolation and explosion-proof options.
2. Commonly used refrigerants in laboratory
glycol chillers:
Commonly used water, brine, chlorinated
solution, and ethylene glycol in laboratory cryogenic refrigeration cycle
devices, the performance, price, and heat capacity of each refrigerant are
different, so the choice can be selected according to the needs.
The freezing point of ethylene glycol is
relatively low, the use temperature is -50 degrees, the performance is
relatively temperature, the price is cheaper, but it is corrosive. The
chlorine-containing solution has a low freezing point, high volatility, and
corrosiveness. The applicable temperature range is -50 to -100°C. Water has
a large specific heat, low density, low price and easy availability. It is
suitable for occasions where the refrigeration temperature is above 0°C. The salt
water can lower the freezing point temperature and expand the cooling range. It
is suitable for medium and low temperature refrigeration systems.
3. Points for attention when using the
laboratory glycol chiller:
A. Before use, you need to check to see if
the location of the device is correct to avoid problems during use.
B. When using the laboratory glycol
chiller, follow the operating instructions for operation, including turning on
and off the machine.
C. Pay attention to good maintenance work,
and perform regular maintenance regularly.
D. When the laboratory glycol chiller fails
during use, it should be solved in time. Some common failures have information
in the instruction manual, which can’t be solved. Contact the manufacturer to
solve it.
Resumir
Laboratory glycol chillers are used in many
industries such as chemicals, new energy, components, industries, etc., and you
need to pay attention to the quality of choice when choosing. Global consulting
sales@lneya.com.
Recomendações relacionadas
-
Instruções de seleção do arrefecedor de reator de 500 litros
1620O chiller para reator de 500 litros é mais utilizado na indústria farmacêutica. Portanto, o usuário precisa selecionar um fabricante regular ao selecionar e, ao mesmo tempo, entender os recursos e a configuração. Para a seleção de 500 litros de r...
Ver detalhes -
Which part of the chip testing system requires high and low temperature control?
1369In the chip testing system, the environmental control equipment requires high and low temperature control. Specifically, this section mainly includes the following two key devices: 2. Temperature control system: For certain testing app...
Ver detalhes -
Descrição da seleção da bomba na unidade de controlo da temperatura do sistema saturado de vapor
1667A unidade de controlo da temperatura do sistema de vaporização é um dos equipamentos mais utilizados na indústria química farmacêutica. O desempenho da unidade de controlo da temperatura do sistema de vaporização LNEYA depende da conceção de todo o sistema e da especi...
Ver detalhes -
Área de aplicação do sistema de controlo de refrigeração e arrefecimento a alta temperatura
1495O sistema de controlo de refrigeração e arrefecimento a alta temperatura é utilizado para suportar reactores de vidro, evaporadores rotativos, tanques de fermentação e calorímetros; amplamente utilizado em petróleo, química, metalurgia, bioquímica, física, testes e...
Ver detalhes
LNEYA Refrigeradores industriais Fabricante Fornecedor











