The industrial cooling and heating temperature control equipment adopts a PID algorithm temperature control system to accurately adjust the temperature based on the detected temperature and the set temperature value, improving the drawbacks of traditional manual control of the reaction kettle.
1. The industrial cooling and heating temperature control equipment, the chiller circulating pump, converts electrical energy into mechanical energy to promote the liquid phase circulation of the heat transfer oil, and transfers heat to the reaction kettle. The heat transfer oil exchanges with the materials in the reaction kettle and then returns to the oil heater, where it is heated again under the pressure of the pump and enters the next cycle. Through repeated cycles, heat is transferred and transported, heated and cooled, or the temperature of the reactor is maintained to meet the temperature requirements required by the production process.
2. When high noise occurs during the operation of the industrial cooling and heating temperature control equipment, the chiller needs to be inspected and promptly addressed if any problems are found. The internal components of the industrial grade cold and hot temperature control thermostat are excessively worn, such as the wear and tear of the cylinder body and valve plate of the plunger pump, as well as the wear and tear of the matching parts between the plunger and the plug hole, causing serious internal leakage in the pump. When the pump outputs high-pressure and low flow oil, flow pulsation will occur, causing high noise.
3. The pump valve plate is also one of the important components that can easily cause noise. Industrial cooling, heating, and temperature control equipment. During use, the water chiller may shorten the unloading groove and change the unloading position due to surface wear or oil sludge deposition at the opening of the unloading groove, resulting in oil trapping and higher noise.
4. When air is mixed into the cold water oil of industrial cooling and heating temperature control equipment, it is easy to form cavitation phenomenon in its high-pressure zone, which spreads in the form of pressure waves, causing oil oscillation and causing cavitation noise in the system.
Recomendações relacionadas
-
-
A importância do equipamento de controlo da temperatura TCU na indústria farmacêutica
9191. condições de baixa temperatura necessárias para reacções bioquímicas no interior do reator: síntese de medicamentos a baixa temperatura, etc. 2. arrefecimento rápido das matérias-primas para evitar a deterioração dos medicamentos, cristalização e extração a baixa temperatura. G...
Ver pormenores -
Descrição da classificação da seleção do refrigerador de baixa temperatura LNEYA
1267Different enterprises and different industries have different requirements for the low-temperature chiller of Wuxi Guanya (LNEYA). The choice of models is also different, so it is better to understand them in the selection. The low temperature chi...
Ver pormenores -
Mal-entendido sobre o funcionamento da caldeira da fábrica
873A caldeira é um equipamento muito comum na fábrica. LNEYA Xiaobian diz a toda a gente que muitas pessoas têm mal-entendidos sobre o assunto. Mal-entendido 1 Quanto maior for a pressão do vapor, melhor. A escolha da pressão de vapor da caldeira depende principalmente ...
Ver pormenores