Ultra-high temperature material cold and hot impact box refrigeration oil
The ultra-high temperature material impact test chamber test device has too much frozen oil in the evaporator, which can also cause insufficient cooling and cause slow cooling. The oil stored in the evaporator of the ultra-high temperature material impact test chamber test device can be directly judged by the hot and cold boundary line of the oil surface. If the oil level is too high, it should be released in time.
Some Freon and refrigerating machine oil dissolve each other. Therefore, when the refrigerant in the refrigeration system of the ultra-high temperature material impact test chamber test device is circulating, it is inevitable that the refrigerating machine oil will remain in the various components, and the residual oil in the heat exchanger will affect Heat transfer coefficient. Especially when the refrigerating machine oil enters the evaporator of the test device, if the structural design or installation is unreasonable, the ultra-high temperature material impact test device will only enter or reduce the refrigerating machine oil, so that the residual refrigerating machine oil in the evaporator is more The more you come, the more serious the heat absorption effect, and the lack of cooling capacity. If you don’t handle it at this point, the temperature will not drop. Therefore, you must carry out the oil draining work.

How to judge that the ultra-high temperature material impact test chamber test device has more refrigeration oil in the evaporation tube and affects the refrigeration is a difficult thing. In the case of the ultra-high temperature material impact test device, there is a significant anomaly, that is, the hoarfrost on the evaporation tube is sparsely pulled, incompletely formed, and is defrosted, if there is no other fault, then It is likely that there is too much residual refrigeration oil in the evaporator tube. To remove the freezer oil in the evaporator of the ultra-high temperature material impact test chamber test device, it must be removed, purged and dried. For the tube type evaporator, it is inconvenient to disassemble, the inlet of the test device evaporator can be blown with compressed air, and then the tube is baked with a blowtorch.
There are also many types of evaporators for the ultra-high temperature material impact test chamber test device. Once there are more refrigeration oils, we need to solve them in time.
Recomendações relacionadas
-
Análise das causas do ruído gerado pelo funcionamento dos refrigeradores de baixa temperatura
999Noise is common in the operation of industrial equipment. There are many reasons for noise, which may be caused by some environmental problems in the installation. When noise is generated, we must first confirm the cause and whether it is an inter...
Ver pormenores -
Working Principle of Glycol Chiller
1128For the low-temperature chiller using ethylene glycol solution, wecall it glycol chiller. Its outlet water temperature is generally below - 10 ℃, and the specific temperature requirements shall be subject to theneeds of users. Glycol chillers ar...
Ver pormenores -
Instruções para a utilização de equipamentos de controlo da temperatura para reactores de isolamento
845A caldeira de reação é um reator comummente utilizado na produção farmacêutica e química. O equipamento de controlo da temperatura da caldeira de reação isolada é realizado através do controlo de duas portas, nomeadamente a válvula de água de aquecimento e a válvula de água de arrefecimento ...
Ver pormenores -
Main differences between indoor chillers and outdoor chillers
853Although indoor chillers and outdoor chillers are both devices used to provide cold water to meet specific cooling needs, they have significant differences in design, installation location, working environment, and heat dissipation methods...
Ver pormenores