The Role of Chemical Refrigeration Temperature Control Unit
In pharmaceutical and chemical plants, the raw materials inside the reactors involved in industrial production require rapid cooling and cooling. In order to achieve this goal, the reactor undergoes direct refrigeration and cooling, thereby indirectly reducing the temperature of the materials inside the reactor.
1. There should be operational records that record the operation status of the unit, and maintenance technical files should be created. Detailed records are conducive to identifying common faults and hidden dangers, and taking effective measures as soon as possible to prevent faults from occurring.
2. Adopting a compressor, matched with a condenser and evaporator, with high efficiency, stable performance, low noise, and long service life. The centralized control of the PLC unit, equipped with an energy ratio of a compressor, can timely and accurately control the matching of the refrigeration capacity and cooling load of the unit, ensuring efficient operation of the unit and reducing operating costs.
3. The internal integration has multiple protection and processing functions, such as water cut-off, low temperature and high temperature, low voltage anti freezing, phase loss delay start reverse phase, overload motor overheating, and oil pressure difference.
3. Full Chinese operation interface, menu style prompts, and the operation status of the unit can be set arbitrarily. The operating environment is home appliances, and the capacity control can adopt four section or three section and no section control systems.
4. The built-in oil pressure system ensures that the compressor maintains lubrication without the need for an oil pump. The oil separator adopts a double-layer filtration method, which has excellent oil filtering effect. The heat converter can fully utilize its capacity
5. The selection of steel pipes makes the contact between the steel pipes and the fins closer, with higher heat transfer efficiency, small volume, light weight, and more compact and reasonable structure.
Recomendações relacionadas
-
Precauções de funcionamento do equipamento de controlo da temperatura do reator da série ZLF/SR
1721O equipamento de controlo da temperatura da chaleira de reação adopta o método de controlo PID, o que melhora consideravelmente a precisão do controlo da temperatura de toda a máquina. O microcomputador para arrefecimento ou aquecimento muda automaticamente para trabalhar de acordo...
Ver detalhes -
O fabricante de congelação a temperaturas ultra-baixas analisa a causa do bloqueio do sistema de refrigeração
2040Com o desenvolvimento contínuo da tecnologia, a tecnologia de refrigeração de temperatura ultrabaixa também está em constante desenvolvimento e os fabricantes também estão a aumentar. Naturalmente, a tecnologia dos diferentes fabricantes é diferente. Uma vez que a refrigeração...
Ver detalhes -
Aspects to be aware of when using an air-cooled all-in-one
1389The air-cooled all-in-one is in operation, unless it is necessary, please do not open the chassis door, otherwise the following adverse consequences may result. When the equipment is subjected to a high temperature test, it is very dangerous to bl...
Ver detalhes -
O fabricante explica quais são as influências do nível de óleo e da diferença de óleo do chiller?
1821O fabricante do chiller diz a todos que, além do sistema de refrigeração, o sistema de óleo lubrificante também é uma parte importante, com seu próprio reservatório de óleo e refrigerador de óleo especial. Portanto, devemos entender a influência do sistema de óleo l...
Ver detalhes
LNEYA Refrigeradores industriais Fabricante Fornecedor