Como resolver o problema do aumento do consumo de energia da bomba centrífuga de refrigeração?
Existem muitas oportunidades para a bomba centrífuga no chiller, mas a falha da bomba centrífuga afectará a utilização do chiller. Portanto, não se preocupe se a potência da bomba centrífuga se tornar maior, descubra a causa a tempo e...
The cooling machine centrifugal pump works by rotating the impeller to make the water centrifugally. Before the pump starts, the pump casing and the suction pipe must be filled with water, and then the motor is started, so that the pump shaft drives the impeller and water to perform high-speed rotary motion. Centrifugal movement occurs, and is thrown to the outer edge of the impeller, and flows into the water pressure pipe of the water pump through the flow path of the volute pump casing.
The reasons for the increase in power are summarized below, as follows:
The matching of the cooling machine pump is unreasonable. The pressure and displacement of the modified pump or the replaced pump are improved compared with the original pump, and the power of the motor is too small; the outlet valve is too large and the pump pressure is too low. The pump displacement exceeds the specified value of the nameplate too much, and the deviation from the working point is too much; the cooling machine packing pressure is too tight; the cooling machine power supply voltage is too low, the current exceeds the rated value; the cooling motor or pump is seriously different, the vibration is serious; the pump The friction between the inner rotor and the stator component is severe; the rotor of the cooling motor is turbulent, the position is not correct, the journal step and the bearing end face or the coupling and the oil seal cover are ground; the cooling coupling coupling buffer damping rubber ring is too tight, and the pump pushes forward The motor coupling and the bearing cover are ground; the balance plate of the cooling machine is not opened, the grinding is severely performed, and the balance return pipe is hot; the radial clearance of the pressure relief sleeve or the balance plate is too small, the deflection is too large, and the operation is worn; When the cooling pump is started, serious internal faults occur, such as the mouth ring, the bushing falling off or the matching clearance is too small; the pump shaft is too rigid and bending deformation.

In the face of the above-mentioned failure of the centrifugal pump of the cooling machine, according to the situation on the site, timely take corresponding measures to deal with it, get in touch with the power supply unit, and adjust the supply voltage to within the specified range;
Adjust the opening degree of the outlet valve to make it run at the normal working condition; properly control the pump pressure and displacement, reduce the running current of the motor; adjust the tightness of the packing gland.
If the above measures can not be eliminated, the pump should be stopped for inspection and treatment. Specific treatment measures: 1 re-empting and draining the air inside the pump; 2 checking and adjusting the lubricating oil pressure, repairing or replacing the bearing bush; 3 replacing the coupling minus Shock rubber ring; 4 repair or replace the balance plate; 5 to carry out three guarantee operations, repair and replace damaged parts; 6 with the professional team to deal with motor failure.
If you still can’t solve the cooling centrifugal pump in time, contact the professional manufacturer for technical guidance!
Recomendações relacionadas
-
A razão pela qual o termóstato de arrefecimento Chiller não arranca subitamente
1018If there are any unexpected situations during the use of the cooling thermostat Chiller, it is important to promptly identify the specific reasons before resolving them, in order to effectively address various issues. For example, what is the re...
Ver pormenores -
Nota de paragem da condensação da depuração de gases de resíduos orgânicos
1178Se o gás residual orgânico for purificado e condensado, se encontrar uma falha durante o funcionamento, deve ser desligado e eliminado a tempo. Então, como é que a purificação e a condensação do gás residual orgânico LNEYA podem ser utilizadas depois de serem desligadas? O ou...
Ver pormenores -
Maintenance Method Of Ultra Low Temp Chiller Refrigeration System
1032The ultra low temp chiller refers to the refrigeration unit whose chilled water temperature reaches below minus 35℃. The unit adopts two-stage compression refrigeration, and the combination of the scroll compressor and the piston compressor is use...
Ver pormenores -
Vantagens do congelador de placas frias
985O método de congelação é utilizado principalmente quando o painel tátil capacitivo de cristais líquidos dos smartphones e tablets apresenta defeitos de produção, tais como bolhas, objectos estranhos, manchas pretas, manchas brancas, colocação incorrecta...
Ver pormenores