Seleção do modelo de controlo da temperatura da TCU e descrição dos parâmetros técnicos
TCU temperature control is also a two-cycle unit single-fluid temperature control system. When selecting the model, it is very important for the whole temperature control reaction. Only the appropriate reaction system is used to exotherm and absorb the whole reaction process. The heat responds to the entire control, so the choice of model is very important.
TCU temperature control model: SR-10
Model SR-10 with operating temperature range of -120~200°C, suitable reaction vessel is 50L-250L, circulating pump flow pressure is controlled at 3m3/h1.5bar, circulating pump can not be adjusted, auxiliary heating power is 10KW, pre- The interface of the heat exchange module is DN25, and electric power, steam, hot oil, hot water, cooling water, chilled water and ultra-low temperature medium can be used as primary energy.
TCU temperature control model: SR-20
Model SR-20 with operating temperature range of -120~200°C, suitable reaction vessel is 100L-500L, circulating pump flow pressure is controlled at 2.4~6.6m3/h1.5bar, circulating pump control can be adjusted by frequency or fixed speed. The auxiliary heating power is 20KW, and the interface of the preheating heat exchange module is DN32.
TCU temperature control model: SR-38
Model SR-38 with operating temperature range of -120~200°C, suitable reaction vessel is 300L-1000L, circulating pump flow pressure is controlled at 5~12m3/h2.5bar, circulating pump control can be adjusted by frequency or constant speed, auxiliary The heating power is 38KW, and the interface of the preheating heat exchange module is DN40.
TCU temperature control model: SR-60
Model SR-60 with operating temperature range of -120~200°C, suitable reaction vessel is 500L-2000L, circulating pump flow pressure is controlled at 11~25m3/h2.5bar, circulating pump control can be adjusted by frequency or constant speed, auxiliary The heating power is 60KW, and the interface of the preheating heat exchange module is DN65.
TCU temperature control model: SR-95
Model SR-95 with operating temperature range of -120~200°C, suitable reaction vessel is 1000L-5000L, circulating pump flow pressure is controlled at 20~50m3/h2.5bar, circulating pump control can be adjusted by frequency or fixed speed, auxiliary The heating power is 95KW, and the interface of the preheating heat exchange module is DN80.
In addition, the energy conversion of TCU temperature control is carried out by heat exchanger and electric heating. In the temperature control mode selection, the material temperature control and jacket temperature control can be freely selected, and the material temperature control accuracy is ±1 °C. Inch / inch color touch screen. The temperature control of the whole TCU is a fully enclosed system. There is no oil mist at high temperature and no moisture in the air at low temperature. The TCU temperature control system does not increase the fluid pressure due to high temperature during operation, and automatically supplements the heat transfer medium at low temperature.
Recomendações relacionadas
-
No laboratório farmacêutico, é selecionada a bomba centrífuga ou a bomba volumétrica?
1521No laboratório farmacêutico, utiliza-se mais uma variedade de equipamentos de refrigeração e, em seguida, como um equipamento mais comum - bombas, principalmente bombas centrífugas, bombas volumétricas. Assim, o amigo utilizador deve ter uma melhor compreensão do seu desempenho...
Ver detalhes -
O requisito de instalação do chiller industrial
1588(1) A fonte de alimentação do chiller adopta uma linha de alimentação trifásica de quatro fios (R, S, T) ligada à linha de incêndio da fonte de alimentação, (N) linha zero, (G) linha de terra..,
Ver detalhes -
Principais diferenças entre os refrigeradores de interior e os refrigeradores de exterior
1462Embora os chillers de interior e os chillers de exterior sejam ambos dispositivos utilizados para fornecer água fria para satisfazer necessidades de arrefecimento específicas, têm diferenças significativas em termos de conceção, local de instalação, ambiente de trabalho e métodos de dissipação de calor.
Ver detalhes -
O que acontecerá com o arrefecimento excessivo do refrigerador de baixa temperatura?
1483Como todos sabemos, o refrigerador de baixa temperatura é um tipo de design de refrigeração profissional amplamente utilizado na indústria. Embora possa proporcionar um ambiente criogénico eficaz, existem alguns fenómenos anormais de sobre-refrigeração. Normalmente, a l...
Ver detalhes