A solução do refrigerador de etilenoglicol está demasiado fria e demasiado quente
When the ethylene glycol chiller solution
is overheated and overcooled during operation, if you don’t understand these
conditions well, you will not be able to operate the equipment well.
The supercooling phenomenon of the solution
of the glycol chiller refers to the condensed saturated liquid is re-cooled by
a certain device and method, so that the temperature is lower than the
saturation temperature under the condensing pressure. -The occurrence of
subcooling can reduce the flash gas generated by the refrigerant liquid in the
throttling process, reduce the specific volume of the flash gas, increase the
unit refrigeration capacity, and increase the superheat of the return gas,
which protects the compressor Wet stroke operation has certain advantages.
The overheating of the ethylene glycol
chiller solution refers to the difference between the saturation temperature
and the saturation temperature after overheating, which is called the degree of
superheat. The method of measuring the degree of superheat is to measure the
evaporation pressure as close as possible to the temperature sensor bulb,
convert the reading to temperature, and then subtract the temperature from the
actual temperature measured at the temperature sensor bulb. The degree of overheating
should be between 5-8°C. A high degree of superheat will cause the compressor discharge
temperature (discharge superheat) to increase, and the compressor’s operating
conditions will deteriorate and its service life will be reduced. Therefore,
the degree of inhalation superheat should be controlled within a certain range.
Due to the length and thermal insulation of
the solution return pipe (suction pipe) of the glycol chiller, the steam in the
pipe is transferred to the outside and heated. This phenomenon is called
“inhalation overheating” or “pipe overheating”. This kind
of overheating will increase the suction temperature of the compressor and
increase the specific volume of the suction steam, resulting in a decrease in
the refrigeration capacity per unit volume and a decrease in the refrigeration
capacity of the compressor. This is detrimental to the refrigeration cycle.
This problem is called “Harmful overheating.” Therefore, shorten the
length of the suction pipe as much as possible to reduce this harmful
overheating.
In some fluorine refrigeration systems that
use expansion valves, the degree of superheat is used to adjust the degree of
opening of the thermal expansion valve. This phenomenon is called
“beneficial overheating.” Similarly, the superheat generated by the
fluorine steam after reheating is also a beneficial superheat.
If the ethylene glycol chiller solution is
too cold or too hot, there are certain beneficial or harmful places. Please pay
attention to understand when you use it.
Recomendações relacionadas
-
Temperature conditions of new energy vehicle batteries
1480When automobile manufacturers continue to improve battery life to overcome the driver's mileage anxiety, the energy density of the large batteries installed is also gradually increasing, which means that the temperature monitoring function of the...
Ver detalhes -
Óleo de transferência de calor de circulador de arrefecimento e aquecimento à prova de explosão
1526Explosion proof cooling and heating circulator is a commonly used temperature control equipment in laboratories. It is used in pharmaceutical, chemical, biological and other industries to provide heat and cold sources for reactors, reactors, etc. ...
Ver detalhes -
Sistema de controlo da temperatura de refrigeração e aquecimento para ensaios aeroespaciais de dissipadores de calor sob vácuo
1341A aplicação do sistema de controlo da temperatura de refrigeração e aquecimento no ensaio de dissipadores de calor em ambiente de vácuo aeroespacial é muito importante. Este equipamento é normalmente utilizado para simular ensaios de desempenho térmico em condições de temperatura extrema...
Ver detalhes -
Sistema de aquecimento por refrigeração LNEYA star SUNDI-320/420W/430W
1857Hoje, vou apresentar o modelo do sistema de aquecimento por refrigeração da LNEYA: SUNDI-320/420W/430W. Tem três tipos de faixa de temperatura média: -30°C~180°C; -40°C~180°C; -40°C~200°C. O sistema de controlo está programado para programar até 10 programas...
Ver detalhes
LNEYA Refrigeradores industriais Fabricante Fornecedor