Seleção e manutenção de um refrigerador de temperatura ultra baixa
Today, a customer came to inquire about our need for a small laboratory water chiller. The specific working condition is to reduce the materials in the 20L stainless steel reactor from normal temperature to minus 30 ℃ in more than one hour. This product is too simple for us. The LT-50 series chiller can easily meet all the operating conditions. For model selection, please remember the basic formula: tank volume (or material weight) * material specific heat * temperature difference/second.
Then, maintenance plays a key role in the stable operation of the equipment. After shutdown, start to use the refrigerant recovery device to recover refrigeration.
After the refrigerant is recovered, open the end cover of the water chamber, clean the circulating water system, and replace the oil filter element; After maintenance and installation, vacuum the system with a vacuum pump and maintain the pressure for 24 hours to ensure good airtightness. In the process of filling refrigerant, it is found that the refrigerant cannot be inhaled. It is confirmed that the system is leaking water, and then find the leak point. First, close the inlet and outlet valves at the water side of the evaporator and condenser. After the water inside the machine is drained, open the covers at both ends of the water side of the evaporator and condenser and fully close the outlet valve of the compressor to form a closed space. Refill refrigerant and mark the leakage point. Then, the evaporator and condenser are dried to remove the residual air in the system. Repeat this for many times to ensure that all the air in the system is discharged. Open the bottom corner valve to drain the residual liquid water in the system. Repeat flushing until no residual liquid water is discharged; Finally, the compressor shall be treated by removing the motor first and then drying it, and the withstand voltage test shall be carried out by professionals; Then conduct overall inspection and maintenance, replace damaged parts, and then assemble the compressor as a whole.
The above is about the selection and maintenance of ultra-low temperature chiller. Later, we will talk about the matters needing attention during installation and use.
Recomendações relacionadas
-
Treatment of organic waste gas by condensation method
1957Condensation treatment of organic waste gas equipment should pay attention to its performance when selecting. It is very necessary to choose high-performance condensation method to treat organic waste gas. So what is the use of organic waste gas f...
Ver detalhes -
The Analysis Of How To Maintain The Low Temperature Circulator In Daily Life
1729Guanya is a leading role in heating cooling circulator. It provides the customers with proposal and technology of controlling the cold and heat, temperature control system with stable property, extending the service life of heating cooling circula...
Ver detalhes -
Instruções de preparação da série TES-5 dedicada ao teste de chips
1586A série TES-5 para teste de chips é utilizada para testes de componentes electrónicos. A forma de detetar com precisão o chip é muito importante. Então, quanto é que sabe sobre a preparação do teste para a série TES-5 para teste de chips? Antes de iniciar o teste da série TES-5...
Ver detalhes -
As principais áreas de aplicação dos chillers refrigerados a ar
1482No mercado nacional e internacional de resfriadores de água industriais, nosso equipamento de resfriamento de água industrial mais comum pode ser dividido em dois tipos diferentes, um tipo é o resfriador de ar industrial, o outro tipo é o resfriador de água industrial...
Ver detalhes
LNEYA Refrigeradores industriais Fabricante Fornecedor