How to check the air tightness of 40 screw freezer?
Air tightness is related to the cooling effect of the entire 40-screw freezer. Therefore, the manufacturer of 40-pin screw freezer of LushiA (LNEYA) recommends that users do 4 inspections, then how to check the work?
This test is carried out on a refrigeration system with a 40-screw freezer evaporating pressure gauge close to or below atmospheric pressure. The vacuum leak test using an external mechanical vacuum pump is generally used in a small 40-hp screw freezer. When the hour hand unscrews the fine screw plug of the suction cut-off valve passage, turn the suction cut-off valve rod several times clockwise to make the suction cut-off valve in the three-way state; use a soft connector with a three-way repair valve and a vacuum pressure gauge The vacuum pump is connected to the multi-purpose interface on the suction shut-off valve; all the valves in the system (including solenoid valve and manual valve) are opened; the vacuum pump power is turned on, and the system is vacuumed until the reading of the vacuum gauge reaches -0.1MPa. After the appropriate time, the suction shut-off valve stem is rotated counterclockwise to withdraw and tighten; for 18~24h, if the vacuum is constant, the vacuum test of the refrigeration system is considered qualified.
The 40-cylinder screw chiller uses the compressor in the system for self-vacuum test when doing air tightness test. For larger refrigeration systems, vacuum test is usually carried out by this method, and self-vacuum is performed by the compressor in the system. First, the exhaust cut-off valve stem is selected clockwise to the end, so that the system loses the circulation passage at the exhaust port of the compressor. Rotate the fine screw plug of the exhaust passage valve counterclockwise to make the exhaust port open to the atmosphere. Open all valves in the system. Short-circuit the contacts of the low-voltage relay and temporarily remove the protection function (recovery afterwards). Start the compressor and let the air in the system discharge into the atmosphere (the suction valve of the compressor should be slowly opened to prevent the gas in the system from being discharged, causing the exhaust pressure to be too high and causing high voltage protection, etc.). Observe the vacuum gauge at the low pressure end until the reading of the vacuum gauge reaches -0.1 MPa. After the appropriate time, the exhaust shutoff valve stem is rotated out and tightened. Hold for 18~24h, if the degree of vacuum is unchanged, it is qualified.
The air tightness check should be checked regularly to check the details of all aspects of the 40 screw freezer from various data.

Recomendações relacionadas
-
What should do if the equipment of the thermal shock test chamber does not reach the set temperature
1234The choice of the manufacturer of the thermal shock test chamber is related to the quality of the thermal shock test chamber. Once the quality is set, the temperature setting of the equipment will not be closed. What should I do if I encounter the...
Ver pormenores -
Instruções de utilização dos vários componentes da máquina de ciclos de alta e baixa temperatura
1137Na máquina de ciclo de alta e baixa temperatura, cada acessório tem as suas próprias vantagens de desempenho. Durante o funcionamento, é necessário ter uma compreensão clara de cada acessório para que o aparelho funcione melhor. O compressor tem a função de comprimir e de...
Ver pormenores -
Cooperação mundial contra a COVID-19, a LNEYA presta apoio dentro das suas possibilidades
1425Na fase atual de transmissão do vírus, é imperativo estudar medicamentos e vacinas eficazes contra o coronavírus. Como fabricante de tecnologia de controlo de temperatura de alta precisão, acreditamos que é da nossa responsabilidade apoiar o trabalho...
Ver pormenores -
refrigeradores hidráulicos refrigeradores industriais/laboratoriais?
805Os chillers hidráulicos não são diretamente equivalentes aos chillers industriais ou aos chillers de laboratório, mas têm uma certa relevância e sobreposição de funções. Todos eles são dispositivos utilizados para proporcionar efeitos de arrefecimento. A principal diferença reside na aplicação...
Ver pormenores