The safety of heat transfer oil in water-cooled chillers
In order to achieve better operating efficiency, water-cooled chillers need to choose branded heat transfer oil, but you need to pay attention to safe placement, a little carelessness will cause adverse effects.
Although the heat transfer oil of the water-cooled chiller has a higher boiling point, it is still a flammable liquid. Therefore, you should pay attention to safety when using it. Improper use may cause fire. The cause of the fire is caused by leakage. There are four main types of leakage and fire:
A. Fire in the heat preservation area.
Common misfire types in organic heat transfer oil systems. The heat transfer oil leaks at the instrument connection and penetrates into the heat preservation area. Then, in the presence of air, the circulating liquid and pipe heat will heat the heat conduction oil and gradually oxidize the liquid, causing the heat preservation area to be ignited and cause a fire.
B. Fire caused by pipeline leakage or burst.
The leakage or burst of the pipeline caused the heat transfer oil to flow into the hot gas flame zone and cause a fire.
C. The flash point causes a fire.
The factors that cause the flash point fire are higher than the low flash point temperature of the heat transfer oil, and there are heat transfer oil, air and fire sources at the same time.
D. Fire caused by process raw materials:
The main reason is that the heat-conducting oil leaks into the heating system, and its process raw materials are easily oxidized and have oxidizing substances, which causes a fire.
In addition to the above four types of fires, more attention should be paid to the use of gas-phase systems. If a large amount of heat transfer oil vapor leaks, aerosol mist may be formed. This mist may cause explosion and combustion in the air when exposed to an open flame.
Therefore, the heat transfer oil of water-cooled chillers is related to its operating efficiency and safety, so it is necessary to do a good job in the repair and maintenance of the hot oil system to prevent the leakage of the heat transfer oil.
Recomendações relacionadas
-
Utilização de refrigeradores a bateria de veículos eléctricos na indústria aplicada
1773Na indústria de veículos elétricos, a bateria é um dos seus principais componentes, com alta dificuldade e natureza complexa, por isso a escolha do chiller para o seu teste também é muito importante. O resfriador de bateria de veículo elétrico LNEYA fornece uma solução...
Ver detalhes -
Porque é que as empresas de fabrico de semicondutores necessitam de equipamento de circulação de aquecimento?
1677Precisão do controlo da temperatura: O processo de fabrico de semicondutores tem requisitos extremamente rigorosos para o controlo da temperatura. O circulador de aquecimento pode proporcionar um controlo preciso da temperatura, assegurando que a temperatura se mantém...
Ver detalhes -
Aplicação do resfriador de água com parafuso
1388A potência do resfriador de água de parafuso é relativamente maior do que a do resfriador de rolagem. É utilizado principalmente no sistema de ar condicionado central ou na refrigeração industrial de grandes dimensões. Pode ser dividido em duas categorias. 1. compressor de refrigeração de parafuso duplo...
Ver detalhes -
Quais são as condições para a reação de descarboxilação? Como controlar a temperatura de aquecimento?
1892A descarboxilação dos ácidos aromáticos é mais fácil do que a dos ácidos gordos. Por exemplo, o ácido benzoico pode ser descarboxilado adicionando um pouco de pó de cobre como catalisador numa solução de quinolina e aquecendo. Quando um grupo fortemente retirador de electrões é...
Ver detalhes
LNEYA Refrigeradores industriais Fabricante Fornecedor